Self-Supervised MRI Reconstruction with Unrolled Diffusion Models

2306.16654

YC

0

Reddit

0

Published 4/17/2024 by Yilmaz Korkmaz, Tolga Cukur, Vishal M. Patel
Self-Supervised MRI Reconstruction with Unrolled Diffusion Models

Abstract

Magnetic Resonance Imaging (MRI) produces excellent soft tissue contrast, albeit it is an inherently slow imaging modality. Promising deep learning methods have recently been proposed to reconstruct accelerated MRI scans. However, existing methods still suffer from various limitations regarding image fidelity, contextual sensitivity, and reliance on fully-sampled acquisitions for model training. To comprehensively address these limitations, we propose a novel self-supervised deep reconstruction model, named Self-Supervised Diffusion Reconstruction (SSDiffRecon). SSDiffRecon expresses a conditional diffusion process as an unrolled architecture that interleaves cross-attention transformers for reverse diffusion steps with data-consistency blocks for physics-driven processing. Unlike recent diffusion methods for MRI reconstruction, a self-supervision strategy is adopted to train SSDiffRecon using only undersampled k-space data. Comprehensive experiments on public brain MR datasets demonstrates the superiority of SSDiffRecon against state-of-the-art supervised, and self-supervised baselines in terms of reconstruction speed and quality. Implementation will be available at https://github.com/yilmazkorkmaz1/SSDiffRecon.

Create account to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents a self-supervised learning approach for accelerating magnetic resonance imaging (MRI) reconstruction using diffusion models.
  • The proposed method, called Self-Supervised MRI Reconstruction with Unrolled Diffusion Models (SSRU), leverages the power of diffusion models and cross-attention transformers to achieve high-quality MRI reconstruction from undersampled k-space data.
  • SSRU is designed to work in a self-supervised manner, eliminating the need for extensive labeled training data, which is often a challenge in medical imaging.

Plain English Explanation

Magnetic resonance imaging (MRI) is a widely used medical imaging technique that allows doctors to see detailed images of the inside of the human body. However, the process of acquiring MRI data can be slow and time-consuming, which can be a problem for patients who need to stay still for long periods.

The researchers in this paper have developed a new method that can help speed up the MRI reconstruction process. Their approach uses a type of machine learning called "diffusion models" and "cross-attention transformers" to generate high-quality MRI images from incomplete or undersampled data.

The key advantage of this method is that it can be trained in a "self-supervised" way, meaning it can learn to reconstruct MRI images without the need for a large dataset of labeled training examples. This is particularly important in the medical field, where it can be challenging to obtain large, annotated datasets.

By using diffusion models and cross-attention transformers, the researchers were able to create an MRI reconstruction system that can produce detailed and accurate images from partial or incomplete data. This could potentially help to reduce the time patients need to spend in the MRI machine, making the process more comfortable and efficient.

Technical Explanation

The paper introduces a self-supervised learning approach called SSRU (Self-Supervised MRI Reconstruction with Unrolled Diffusion Models) for accelerating MRI reconstruction. SSRU leverages the power of diffusion models and cross-attention transformers to achieve high-quality MRI reconstruction from undersampled k-space data.

The key components of SSRU include:

  1. Diffusion Model: SSRU uses a diffusion model, which is a type of generative model that can learn to generate realistic images by iteratively adding noise to the data and then learning to reverse the process. This allows the model to generate high-quality MRI images from incomplete or undersampled data.

  2. Cross-Attention Transformers: SSRU incorporates cross-attention transformers, which are a type of neural network architecture that can effectively capture long-range dependencies in the data. This helps the model better understand the complex structure of MRI images and improve the reconstruction quality.

  3. Self-Supervised Learning: SSRU is designed to work in a self-supervised manner, meaning it can learn to reconstruct MRI images without the need for a large labeled dataset. Instead, the model is trained on the available k-space data, which is more readily available than fully reconstructed MRI images.

The paper presents experiments demonstrating the effectiveness of SSRU in accelerating MRI reconstruction compared to traditional methods. The results show that SSRU can achieve high-quality MRI reconstruction from significantly undersampled k-space data, potentially reducing the time patients need to spend in the MRI machine.

Critical Analysis

The paper presents a promising approach for accelerating MRI reconstruction using self-supervised learning, but it also acknowledges some limitations and areas for further research:

  1. Generalization to Different MRI Modalities: The paper focuses on evaluating SSRU on 2D multi-coil MRI data, but it is not clear how well the method would generalize to other MRI modalities, such as 3D imaging or different contrast types.

  2. Computational Complexity: While SSRU can achieve high-quality reconstruction, the use of diffusion models and transformers may introduce additional computational complexity compared to traditional MRI reconstruction methods. The authors should address the trade-offs between reconstruction quality and computational efficiency.

  3. Clinical Validation: The paper demonstrates the effectiveness of SSRU on benchmark datasets, but further research is needed to assess the performance and clinical utility of the method in real-world clinical settings.

  4. Interpretability: As with many deep learning-based approaches, the inner workings of SSRU may be difficult to interpret, which could be a concern for clinical applications where transparency and explainability are important.

Overall, the paper presents a promising approach that leverages the strengths of diffusion models and transformers for self-supervised MRI reconstruction. However, additional research is needed to address the limitations and ensure the clinical viability of the method.

Conclusion

The paper introduces a self-supervised learning approach called SSRU (Self-Supervised MRI Reconstruction with Unrolled Diffusion Models) that can accelerate MRI reconstruction by leveraging the power of diffusion models and cross-attention transformers. The key advantage of SSRU is its ability to perform high-quality MRI reconstruction from undersampled k-space data in a self-supervised manner, eliminating the need for extensive labeled training data.

The results presented in the paper demonstrate the effectiveness of SSRU in generating detailed and accurate MRI images from partial or incomplete data, which could potentially help to reduce the time patients need to spend in the MRI machine. While the paper acknowledges some limitations, such as the need for further validation on different MRI modalities and clinical settings, the proposed approach represents an important step forward in accelerating MRI reconstruction and improving the overall efficiency and patient experience in medical imaging.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Related Papers

Adaptive Self-Supervised Consistency-Guided Diffusion Model for Accelerated MRI Reconstruction

Adaptive Self-Supervised Consistency-Guided Diffusion Model for Accelerated MRI Reconstruction

Mojtaba Safari, Zach Eidex, Shaoyan Pan, Richard L. J. Qiu, Xiaofeng Yang

YC

0

Reddit

0

Purpose: To propose a self-supervised deep learning-based compressed sensing MRI (DL-based CS-MRI) method named Adaptive Self-Supervised Consistency Guided Diffusion Model (ASSCGD) to accelerate data acquisition without requiring fully sampled datasets. Materials and Methods: We used the fastMRI multi-coil brain axial T2-weighted (T2-w) dataset from 1,376 cases and single-coil brain quantitative magnetization prepared 2 rapid acquisition gradient echoes (MP2RAGE) T1 maps from 318 cases to train and test our model. Robustness against domain shift was evaluated using two out-of-distribution (OOD) datasets: multi-coil brain axial postcontrast T1 -weighted (T1c) dataset from 50 cases and axial T1-weighted (T1-w) dataset from 50 patients. Data were retrospectively subsampled at acceleration rates R in {2x, 4x, 8x}. ASSCGD partitions a random sampling pattern into two disjoint sets, ensuring data consistency during training. We compared our method with ReconFormer Transformer and SS-MRI, assessing performance using normalized mean squared error (NMSE), peak signal-to-noise ratio (PSNR), and structural similarity index (SSIM). Statistical tests included one-way analysis of variance (ANOVA) and multi-comparison Tukey's Honesty Significant Difference (HSD) tests. Results: ASSCGD preserved fine structures and brain abnormalities visually better than comparative methods at R = 8x for both multi-coil and single-coil datasets. It achieved the lowest NMSE at R in {4x, 8x}, and the highest PSNR and SSIM values at all acceleration rates for the multi-coil dataset. Similar trends were observed for the single-coil dataset, though SSIM values were comparable to ReconFormer at R in {2x, 8x}. These results were further confirmed by the voxel-wise correlation scatter plots. OOD results showed significant (p << 10^-5 ) improvements in undersampled image quality after reconstruction.

Read more

6/26/2024

🔗

Fast Controllable Diffusion Models for Undersampled MRI Reconstruction

Wei Jiang, Zhuang Xiong, Feng Liu, Nan Ye, Hongfu Sun

YC

0

Reddit

0

Supervised deep learning methods have shown promise in undersampled Magnetic Resonance Imaging (MRI) reconstruction, but their requirement for paired data limits their generalizability to the diverse MRI acquisition parameters. Recently, unsupervised controllable generative diffusion models have been applied to undersampled MRI reconstruction, without paired data or model retraining for different MRI acquisitions. However, diffusion models are generally slow in sampling and state-of-the-art acceleration techniques can lead to sub-optimal results when directly applied to the controllable generation process. This study introduces a new algorithm called Predictor-Projector-Noisor (PPN), which enhances and accelerates controllable generation of diffusion models for undersampled MRI reconstruction. Our results demonstrate that PPN produces high-fidelity MR images that conform to undersampled k-space measurements with significantly shorter reconstruction time than other controllable sampling methods. In addition, the unsupervised PPN accelerated diffusion models are adaptable to different MRI acquisition parameters, making them more practical for clinical use than supervised learning techniques.

Read more

6/12/2024

Rethinking Diffusion Model for Multi-Contrast MRI Super-Resolution

Rethinking Diffusion Model for Multi-Contrast MRI Super-Resolution

Guangyuan Li, Chen Rao, Juncheng Mo, Zhanjie Zhang, Wei Xing, Lei Zhao

YC

0

Reddit

0

Recently, diffusion models (DM) have been applied in magnetic resonance imaging (MRI) super-resolution (SR) reconstruction, exhibiting impressive performance, especially with regard to detailed reconstruction. However, the current DM-based SR reconstruction methods still face the following issues: (1) They require a large number of iterations to reconstruct the final image, which is inefficient and consumes a significant amount of computational resources. (2) The results reconstructed by these methods are often misaligned with the real high-resolution images, leading to remarkable distortion in the reconstructed MR images. To address the aforementioned issues, we propose an efficient diffusion model for multi-contrast MRI SR, named as DiffMSR. Specifically, we apply DM in a highly compact low-dimensional latent space to generate prior knowledge with high-frequency detail information. The highly compact latent space ensures that DM requires only a few simple iterations to produce accurate prior knowledge. In addition, we design the Prior-Guide Large Window Transformer (PLWformer) as the decoder for DM, which can extend the receptive field while fully utilizing the prior knowledge generated by DM to ensure that the reconstructed MR image remains undistorted. Extensive experiments on public and clinical datasets demonstrate that our DiffMSR outperforms state-of-the-art methods.

Read more

4/9/2024

🎯

CL-MRI: Self-Supervised Contrastive Learning to Improve the Accuracy of Undersampled MRI Reconstruction

Mevan Ekanayake, Zhifeng Chen, Mehrtash Harandi, Gary Egan, Zhaolin Chen

YC

0

Reddit

0

In Magnetic Resonance Imaging (MRI), image acquisitions are often undersampled in the measurement domain to accelerate the scanning process, at the expense of image quality. However, image quality is a crucial factor that influences the accuracy of clinical diagnosis; hence, high-quality image reconstruction from undersampled measurements has been a key area of research. Recently, deep learning (DL) methods have emerged as the state-of-the-art for MRI reconstruction, typically involving deep neural networks to transform undersampled MRI images into high-quality MRI images through data-driven processes. Nevertheless, there is clear and significant room for improvement in undersampled DL MRI reconstruction to meet the high standards required for clinical diagnosis, in terms of eliminating aliasing artifacts and reducing image noise. In this paper, we introduce a self-supervised pretraining procedure using contrastive learning to improve the accuracy of undersampled DL MRI reconstruction. We use contrastive learning to transform the MRI image representations into a latent space that maximizes mutual information among different undersampled representations and optimizes the information content at the input of the downstream DL reconstruction models. Our experiments demonstrate improved reconstruction accuracy across a range of acceleration factors and datasets, both quantitatively and qualitatively. Furthermore, our extended experiments validate the proposed framework's robustness under adversarial conditions, such as measurement noise, different k-space sampling patterns, and pathological abnormalities, and also prove the transfer learning capabilities on MRI datasets with completely different anatomy. Additionally, we conducted experiments to visualize and analyze the properties of the proposed MRI contrastive learning latent space.

Read more

5/31/2024