Overview

  • This paper describes a method for accelerating real-time cardiac MRI (magnetic resonance imaging) data acquisition and reconstruction, enabling in-magnet staged exercise monitoring.
  • The key innovations include:
    • Accelerated real-time cine imaging and flow quantification during staged exercise inside the MRI scanner.
    • Leveraging deep learning-based reconstruction techniques to enable high-quality imaging without sacrificing temporal resolution.
    • Integrating exercise staging hardware into the MRI system for seamless data acquisition.

Plain English Explanation

The researchers have developed a way to perform real-time cardiac MRI scans while a person is exercising inside the MRI machine. Normally, MRI scans require the patient to remain very still, which makes it difficult to study how the heart functions during exercise.

<a href="https://aimodels.fyi/papers/arxiv/accelerating-cardiac-mri-reconstruction-cmratt-attention-driven">This new technique uses advanced imaging reconstruction methods</a> to produce clear, high-quality images of the heart even when the person is moving around. The researchers also integrated special exercise equipment into the MRI machine, allowing the person to safely perform various exercise routines while their heart is being imaged.

This is significant because it gives doctors a much better understanding of how the heart responds to exercise in real-time. Previously, they would have to rely on measurements taken before or after exercise, which don't provide the same level of detail. With this new approach, doctors can observe the heart's behavior as it happens, which could lead to improved diagnosis and treatment of heart conditions.

Technical Explanation

The study utilized a combination of accelerated real-time cine imaging and flow quantification techniques to enable in-magnet staged exercise monitoring. <a href="https://aimodels.fyi/papers/arxiv/inline-ai-open-source-deep-learning-inference">Deep learning-based reconstruction methods</a> were leveraged to maintain high-quality imaging without sacrificing temporal resolution during exercise.

The researchers integrated an exercise staging system directly into the MRI scanner, allowing subjects to perform various exercise routines while their heart was being imaged. This setup enabled continuous monitoring of cardiac function under physiologically relevant conditions.

<a href="https://aimodels.fyi/papers/arxiv/efficient-post-processing-diffusion-tensor-cardiac-magnetic">Advanced image processing and analysis techniques</a> were employed to extract clinically relevant parameters, such as ventricular volumes, flows, and myocardial deformation, from the accelerated real-time data. The authors demonstrated the feasibility and clinical utility of this approach through case studies involving healthy subjects and patients with cardiovascular disease.

Critical Analysis

The paper presents a promising approach to advancing cardiac MRI capabilities, particularly for the assessment of cardiovascular function during exercise. The integration of exercise equipment directly into the MRI system is a significant technical achievement that enables a more comprehensive evaluation of cardiac performance under physiologically relevant conditions.

However, the study is limited by its relatively small sample size, which may restrict the generalizability of the findings. <a href="https://aimodels.fyi/papers/arxiv/relaxometry-guided-quantitative-cardiac-magnetic-resonance-image">Further research with larger patient cohorts</a> would be necessary to more thoroughly validate the clinical utility of this technique and its impact on patient management.

Additionally, the paper does not provide a detailed analysis of the potential limitations or challenges associated with the deep learning-based reconstruction methods employed. <a href="https://aimodels.fyi/papers/arxiv/new-method-modeling-multi-stage-decision-making">Exploring the robustness and reliability of these algorithms under various exercise conditions</a> would be an important area for future investigation.

Conclusion

This study demonstrates a significant advancement in cardiac MRI technology, enabling real-time imaging and flow quantification during in-magnet staged exercise. The integration of exercise equipment directly into the MRI system and the leveraging of deep learning-based reconstruction techniques are key innovations that could lead to improved understanding and management of cardiovascular disease. While further research is needed to establish the clinical utility of this approach, the findings presented in this paper represent an important step forward in the field of cardiac imaging and functional assessment.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Accelerated Real-time Cine and Flow under In-magnet Staged Exercise
Total Score

0

Accelerated Real-time Cine and Flow under In-magnet Staged Exercise

Preethi Chandrasekaran, Chong Chen, Yingmin Liu, Syed Murtaza Arshad, Christopher Crabtree, Matthew Tong, Yuchi Han, Rizwan Ahmad

Background: Cardiovascular magnetic resonance imaging (CMR) is a wellestablished imaging tool for diagnosing and managing cardiac conditions. The integration of exercise stress with CMR (ExCMR) can enhance its diagnostic capacity. Despite recent advances in CMR technology, quantitative ExCMR during exercise remains technically challenging due to motion artifacts and limited spatial and temporal resolution. Methods: This study investigated the feasibility of biventricular functional and hemodynamic assessment using real-time (RT) ExCMR during a staged exercise protocol in 24 healthy volunteers. We applied a coil reweighting technique and employed high acceleration rates to minimize motion blurring and artifacts. We further applied a beat-selection technique that identified beats from the endexpiratory phase to minimize the impact of respiration-induced through-plane motion. Additionally, results from six patients were presented to demonstrate clinical feasibility. Results: Our findings indicated a consistent decrease in end-systolic volume and stable end-diastolic volume across exercise intensities, leading to increased stroke volume and ejection fraction. The selection of end-expiratory beats enhanced the repeatability of cardiac function parameters, as shown by scan-rescan tests in nine volunteers. High scores from a blinded image quality assessment indicated that coil reweighting effectively minimized motion artifacts. Conclusions: This study demonstrated the feasibility of RT ExCMR with inmagnet exercise in healthy subjects and patients. Our results indicate that high acceleration rates, coil reweighting, and selection of respiratory phase-specific heartbeats enhance image quality and repeatability of quantitative RT ExCMR.

Read more

5/24/2024

Improved 3D Whole Heart Geometry from Sparse CMR Slices
Total Score

0

Improved 3D Whole Heart Geometry from Sparse CMR Slices

Yiyang Xu, Hao Xu, Matthew Sinclair, Esther Puyol-Ant'on, Steven A Niederer, Amedeo Chiribiri, Steven E Williams, Michelle C Williams, Alistair A Young

Cardiac magnetic resonance (CMR) imaging and computed tomography (CT) are two common non-invasive imaging methods for assessing patients with cardiovascular disease. CMR typically acquires multiple sparse 2D slices, with unavoidable respiratory motion artefacts between slices, whereas CT acquires isotropic dense data but uses ionising radiation. In this study, we explore the combination of Slice Shifting Algorithm (SSA), Spatial Transformer Network (STN), and Label Transformer Network (LTN) to: 1) correct respiratory motion between segmented slices, and 2) transform sparse segmentation data into dense segmentation. All combinations were validated using synthetic motion-corrupted CMR slice segmentation generated from CT in 1699 cases, where the dense CT serves as the ground truth. In 199 testing cases, SSA-LTN achieved the best results for Dice score and Huasdorff distance (94.0% and 4.7 mm respectively, average over 5 labels) but gave topological errors in 8 cases. STN was effective as a plug-in tool for correcting all topological errors with minimal impact on overall performance (93.5% and 5.0 mm respectively). SSA also proves to be a valuable plug-in tool, enhancing performance over both STN-based and LTN-based models. The code for these different combinations is available at https://github.com/XESchong/STACOM2024.

Read more

8/15/2024

🔄

Total Score

0

Motion-compensated MR CINE reconstruction with reconstruction-driven motion estimation

Jiazhen Pan, Wenqi Huang, Daniel Rueckert, Thomas Kustner, Kerstin Hammernik

In cardiac CINE, motion-compensated MR reconstruction (MCMR) is an effective approach to address highly undersampled acquisitions by incorporating motion information between frames. In this work, we propose a novel perspective for addressing the MCMR problem and a more integrated and efficient solution to the MCMR field. Contrary to state-of-the-art (SOTA) MCMR methods which break the original problem into two sub-optimization problems, i.e. motion estimation and reconstruction, we formulate this problem as a single entity with one single optimization. Our approach is unique in that the motion estimation is directly driven by the ultimate goal, reconstruction, but not by the canonical motion-warping loss (similarity measurement between motion-warped images and target images). We align the objectives of motion estimation and reconstruction, eliminating the drawbacks of artifacts-affected motion estimation and therefore error-propagated reconstruction. Further, we can deliver high-quality reconstruction and realistic motion without applying any regularization/smoothness loss terms, circumventing the non-trivial weighting factor tuning. We evaluate our method on two datasets: 1) an in-house acquired 2D CINE dataset for the retrospective study and 2) the public OCMR cardiac dataset for the prospective study. The conducted experiments indicate that the proposed MCMR framework can deliver artifact-free motion estimation and high-quality MR images even for imaging accelerations up to 20x, outperforming SOTA non-MCMR and MCMR methods in both qualitative and quantitative evaluation across all experiments. The code is available at https://github.com/JZPeterPan/MCMR-Recon-Driven-Motion.

Read more

8/19/2024

🖼️

Total Score

0

Joint image reconstruction and segmentation of real-time cardiac MRI in free-breathing using a model based on disentangled representation learning

Tobias Wech, Oliver Schad, Simon Sauer, Jonas Kleineisel, Nils Petri, Peter Nordbeck, Thorsten A. Bley, Bettina Bae{ss}ler, Bernhard Petritsch, Julius F. Heidenreich

A joint image reconstruction and segmentation approach based on disentangled representation learning was trained to enable cardiac cine MR imaging in real-time and under free-breathing. An exploratory feasibility study tested the proposed method in undersampled real-time acquisitions based on an in-house developed spiral bSSFP pulse sequence in eight healthy participants and five patients with intermittent atrial fibrillation. Images and predicted LV segmentations were compared to the reference standard of ECG-gated segmented Cartesian cine in repeated breath-holds and corresponding manual segmentation. On a 5-point Likert scale, image quality of the real-time breath-hold approach and Cartesian cine was comparable in healthy participants (RT-BH: 1.99 $pm$ .98, Cartesian: 1.94 $pm$ .86, p=.052), but slightly inferior in free-breathing (RT-FB: 2.40 $pm$ .98, p<.001). In patients with arrhythmia, image quality from both real-time approaches was favourable (RT-BH: 2.10 $pm$ 1.28, p<.001, RT-FB: 2.40 $pm$ 1.13, p<.001, Cartesian: 2.68 $pm$ 1.13). Intra-observer reliability was good (ICC=.77, 95%-confidence interval [.75, .79], p<.001). In functional analysis, a positive bias was observed for ejection fractions derived from the proposed model compared to the clinical reference standard (RT-BH mean EF: 58.5 $pm$ 5.6%, bias: +3.47%, 95%-confidence interval [-.86, 7.79%], RT-FB mean: 57.9 $pm$ 10.6%, bias: +1.45%, [-3.02, 5.91%], Cartesian mean: 54.9 $pm$ 6.7%). The introduced real-time MR imaging technique is capable of acquiring high-quality cardiac cine data in 1-2 minutes without the need for ECG gating and breath-holds. It thus offers a promising alternative to the current clinical practice of segmented acquisition, with shorter scan times, higher patient comfort and increased robustness to arrhythmia and patient incompliance.

Read more