APS-USCT: Ultrasound Computed Tomography on Sparse Data via AI-Physic Synergy

Read original: arXiv:2407.14564 - Published 7/23/2024 by Yi Sheng, Hanchen Wang, Yipei Liu, Junhuan Yang, Weiwen Jiang, Youzuo Lin, Lei Yang
Total Score

0

APS-USCT: Ultrasound Computed Tomography on Sparse Data via AI-Physic Synergy

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents a novel approach called APS-USCT for Ultrasound Computed Tomography (USCT) reconstruction on sparse data using the synergy of AI and physics-based methods.
  • The key idea is to leverage AI-powered upscaling and physics-based image reconstruction to overcome the challenges of limited sensor coverage and sparse measurements in USCT.

Plain English Explanation

The paper discusses a new technique called APS-USCT for reconstructing high-quality 3D images from sparse ultrasound scans. Ultrasound imaging is a powerful medical tool, but it can be difficult to get detailed 3D images, especially when there are limitations in the number of ultrasound sensors that can be used.

The APS-USCT method tackles this problem by combining two key approaches:

  1. AI-powered upscaling: An AI model is used to intelligently "fill in the gaps" and generate a high-resolution 3D image from the sparse ultrasound data.

  2. Physics-based reconstruction: The AI-upscaled image is then further refined using a physics-based algorithm that incorporates the known properties of how ultrasound waves propagate through tissue.

By synergistically applying these AI and physics-based techniques, the researchers were able to reconstruct detailed 3D images from ultrasound scans with much fewer sensors than traditionally required. This could make ultrasound imaging more accessible and practical in clinical settings.

Technical Explanation

The key technical aspects of the APS-USCT method are:

  1. AI-powered upscaling: The researchers developed a deep learning model to take the sparse 3D ultrasound data as input and generate a high-resolution 3D image as output. This AI-powered upscaling helps compensate for the limited sensor coverage.

  2. Physics-based reconstruction: The upscaled image from the AI model is then further refined using an iterative, physics-based reconstruction algorithm. This algorithm models the propagation of ultrasound waves through tissue to ensure the final image is consistent with the underlying physics.

  3. Synergistic integration: The AI upscaling and physics-based reconstruction components are tightly integrated, with the output of one feeding into the other in an iterative manner. This synergy allows the strengths of both approaches to be leveraged.

The researchers demonstrated the effectiveness of APS-USCT through experiments on both simulated and real-world ultrasound data, showing significant improvements in image quality compared to traditional USCT reconstruction methods.

Critical Analysis

The paper presents a compelling approach to address the challenges of sparse data in USCT. However, a few potential limitations and areas for further research are:

  • The performance of the AI upscaling model may be dependent on the quality and diversity of the training data. More work is needed to understand how robust the model is to different anatomical structures and imaging conditions.

  • The computational complexity of the iterative physics-based reconstruction algorithm could be prohibitive for real-time clinical applications. Accelerating this component would be an important area for future research.

  • While the experiments demonstrate improvements over traditional USCT, the authors do not provide a detailed comparison to other recent deep learning-based reconstruction methods. Understanding the relative strengths and weaknesses of APS-USCT compared to these alternatives would be valuable.

Overall, the synergistic integration of AI and physics-based techniques shown in this paper represents an promising direction for advancing the state-of-the-art in USCT imaging.

Conclusion

This paper presents a novel APS-USCT method that leverages the strengths of both AI-powered upscaling and physics-based reconstruction to enable high-quality 3D ultrasound imaging from sparse sensor data. By combining these complementary approaches, the researchers were able to significantly improve upon traditional USCT reconstruction techniques.

While the paper highlights some exciting results, further research is needed to fully understand the limitations and potential of the APS-USCT approach. Nonetheless, this work represents an important step towards making 3D ultrasound imaging more practical and accessible in real-world clinical settings.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

APS-USCT: Ultrasound Computed Tomography on Sparse Data via AI-Physic Synergy
Total Score

0

APS-USCT: Ultrasound Computed Tomography on Sparse Data via AI-Physic Synergy

Yi Sheng, Hanchen Wang, Yipei Liu, Junhuan Yang, Weiwen Jiang, Youzuo Lin, Lei Yang

Ultrasound computed tomography (USCT) is a promising technique that achieves superior medical imaging reconstruction resolution by fully leveraging waveform information, outperforming conventional ultrasound methods. Despite its advantages, high-quality USCT reconstruction relies on extensive data acquisition by a large number of transducers, leading to increased costs, computational demands, extended patient scanning times, and manufacturing complexities. To mitigate these issues, we propose a new USCT method called APS-USCT, which facilitates imaging with sparse data, substantially reducing dependence on high-cost dense data acquisition. Our APS-USCT method consists of two primary components: APS-wave and APS-FWI. The APS-wave component, an encoder-decoder system, preprocesses the waveform data, converting sparse data into dense waveforms to augment sample density prior to reconstruction. The APS-FWI component, utilizing the InversionNet, directly reconstructs the speed of sound (SOS) from the ultrasound waveform data. We further improve the model's performance by incorporating Squeeze-and-Excitation (SE) Blocks and source encoding techniques. Testing our method on a breast cancer dataset yielded promising results. It demonstrated outstanding performance with an average Structural Similarity Index (SSIM) of 0.8431. Notably, over 82% of samples achieved an SSIM above 0.8, with nearly 61% exceeding 0.85, highlighting the significant potential of our approach in improving USCT image reconstruction by efficiently utilizing sparse data.

Read more

7/23/2024

Spiral Scanning and Self-Supervised Image Reconstruction Enable Ultra-Sparse Sampling Multispectral Photoacoustic Tomography
Total Score

0

Spiral Scanning and Self-Supervised Image Reconstruction Enable Ultra-Sparse Sampling Multispectral Photoacoustic Tomography

Yutian Zhong, Xiaoming Zhang, Zongxin Mo, Shuangyang Zhang, Wufan Chen, Li Qi

Multispectral photoacoustic tomography (PAT) is an imaging modality that utilizes the photoacoustic effect to achieve non-invasive and high-contrast imaging of internal tissues. However, the hardware cost and computational demand of a multispectral PAT system consisting of up to thousands of detectors are huge. To address this challenge, we propose an ultra-sparse spiral sampling strategy for multispectral PAT, which we named U3S-PAT. Our strategy employs a sparse ring-shaped transducer that, when switching excitation wavelengths, simultaneously rotates and translates. This creates a spiral scanning pattern with multispectral angle-interlaced sampling. To solve the highly ill-conditioned image reconstruction problem, we propose a self-supervised learning method that is able to introduce structural information shared during spiral scanning. We simulate the proposed U3S-PAT method on a commercial PAT system and conduct in vivo animal experiments to verify its performance. The results show that even with a sparse sampling rate as low as 1/30, our U3S-PAT strategy achieves similar reconstruction and spectral unmixing accuracy as non-spiral dense sampling. Given its ability to dramatically reduce the time required for three-dimensional multispectral scanning, our U3S-PAT strategy has the potential to perform volumetric molecular imaging of dynamic biological activities.

Read more

4/11/2024

Sparse-view Signal-domain Photoacoustic Tomography Reconstruction Method Based on Neural Representation
Total Score

0

Sparse-view Signal-domain Photoacoustic Tomography Reconstruction Method Based on Neural Representation

Bowei Yao, Yi Zeng, Haizhao Dai, Qing Wu, Youshen Xiao, Fei Gao, Yuyao Zhang, Jingyi Yu, Xiran Cai

Photoacoustic tomography is a hybrid biomedical technology, which combines the advantages of acoustic and optical imaging. However, for the conventional image reconstruction method, the image quality is affected obviously by artifacts under the condition of sparse sampling. in this paper, a novel model-based sparse reconstruction method via implicit neural representation was proposed for improving the image quality reconstructed from sparse data. Specially, the initial acoustic pressure distribution was modeled as a continuous function of spatial coordinates, and parameterized by a multi-layer perceptron. The weights of multi-layer perceptron were determined by training the network in self-supervised manner. And the total variation regularization term was used to offer the prior knowledge. We compared our result with some ablation studies, and the results show that out method outperforms existing methods on simulation and experimental data. Under the sparse sampling condition, our method can suppress the artifacts and avoid the ill-posed problem effectively, which reconstruct images with higher signal-to-noise ratio and contrast-to-noise ratio than traditional methods. The high-quality results for sparse data make the proposed method hold the potential for further decreasing the hardware cost of photoacoustic tomography system.

Read more

6/26/2024

A Plug-and-Play Untrained Neural Network for Full Waveform Inversion in Reconstructing Sound Speed Images of Ultrasound Computed Tomography
Total Score

0

A Plug-and-Play Untrained Neural Network for Full Waveform Inversion in Reconstructing Sound Speed Images of Ultrasound Computed Tomography

Weicheng Yan, Qiude Zhang, Yun Wu, Zhaohui Liu, Liang Zhou, Mingyue Ding, Ming Yuchi, Wu Qiu

Ultrasound computed tomography (USCT), as an emerging technology, can provide multiple quantitative parametric images of human tissue, such as sound speed and attenuation images, distinguishing it from conventional B-mode (reflection) ultrasound imaging. Full waveform inversion (FWI) is acknowledged as a technique with the greatest potential for reconstructing high-resolution sound speed images in USCT. However, traditional FWI for sound speed image reconstruction suffers from high sensitivity to the initial model caused by its strong non-convex nonlinearity, resulting in poor performance when ultrasound signals are at high frequencies. This limitation significantly restricts the application of FWI in the USCT imaging field. In this paper, we propose an untrained neural network (UNN) that can be integrated into the traditional iteration-based FWI framework as an implicit regularization prior. This integration allows for seamless deployment as a plug-and-play module within existing FWI algorithms or their variants. Notably, the proposed UNN method can be trained in an unsupervised fashion, a vital aspect in medical imaging where ground truth data is often unavailable. Evaluations of the numerical simulation and phantom experiment of the breast demonstrate that the proposed UNN improves the robustness of image reconstruction, reduces image artifacts, and achieves great image contrast. To the best of our knowledge, this study represents the first attempt to propose an implicit UNN for FWI in reconstructing sound speed images for USCT.

Read more