Attention Incorporated Network for Sharing Low-rank, Image and K-space Information during MR Image Reconstruction to Achieve Single Breath-hold Cardiac Cine Imaging

Read original: arXiv:2407.03034 - Published 7/4/2024 by Siying Xu, Kerstin Hammernik, Andreas Lingg, Jens Kuebler, Patrick Krumm, Daniel Rueckert, Sergios Gatidis, Thomas Kuestner
Total Score

0

Attention Incorporated Network for Sharing Low-rank, Image and K-space Information during MR Image Reconstruction to Achieve Single Breath-hold Cardiac Cine Imaging

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper introduces a novel attention-based network architecture called CMRATT (Cardiac MRI Attention-driven Transformation) for accelerating cardiac MRI reconstruction to enable single breath-hold imaging.
  • The network leverages low-rank, image-space, and k-space information to reconstruct high-quality cardiac cine images from undersampled data.
  • Attention mechanisms are incorporated to adaptively fuse and propagate these complementary information sources for improved reconstruction performance.

Plain English Explanation

Magnetic resonance imaging (MRI) is a powerful medical imaging technique that can capture detailed images of the heart. However, traditional cardiac MRI scans can take several minutes, requiring the patient to hold their breath multiple times. This can be challenging for some patients, such as those with heart or lung conditions.

The researchers in this paper developed a new deep learning-based method called CMRATT to address this issue. CMRATT uses a specialized neural network architecture to reconstruct high-quality cardiac MRI images from data that is collected much faster, in a single breath-hold.

The key innovation is that CMRATT leverages three different types of information to help it reconstruct the images: 1) low-rank information that captures the overall structure of the heart, 2) image-space information that shows the detailed anatomy, and 3) k-space information that represents the raw data collected by the MRI scanner.

By adaptively combining these complementary information sources using attention mechanisms, CMRATT is able to produce high-quality cardiac MRI images from data collected much faster than traditional methods. This could enable more efficient and comfortable cardiac MRI exams for patients.

Technical Explanation

The key technical innovation in this paper is the CMRATT network architecture, which incorporates several novel components to accelerate cardiac MRI reconstruction:

  1. Low-rank Modeling: The network includes a low-rank modeling module that learns a compact representation of the cardiac anatomy. This helps capture the overall structure of the heart.

  2. Image-space and K-space Modeling: Separate branches of the network model the image-space and k-space representations of the data. This allows the network to leverage both the high-level structural information and the detailed raw measurement data.

  3. Attention-based Fusion: Attention mechanisms are used to adaptively fuse the low-rank, image-space, and k-space features. This allows the network to selectively emphasize the most relevant information for accurate reconstruction.

  4. Progressive Reconstruction: The network uses a progressive reconstruction approach, gradually refining the image quality over multiple stages. This helps stabilize the training process and improve convergence.

The authors evaluate CMRATT on challenging cardiac MRI datasets and demonstrate significant improvements in reconstruction quality and speed compared to prior state-of-the-art methods. The single breath-hold imaging capability enabled by CMRATT could lead to more patient-friendly cardiac MRI exams.

Critical Analysis

The authors have provided a thorough evaluation of CMRATT, including comparisons to multiple prior methods on various cardiac MRI datasets. The results indicate that the proposed approach offers substantial benefits in terms of reconstruction quality and scan time reduction.

However, the paper does not address certain practical considerations. For example, the method was only evaluated on healthy volunteers, and its performance on patients with cardiac conditions or other confounding factors is unclear. Additionally, the computational complexity and runtime of CMRATT are not fully characterized, which could be important for real-world clinical deployment.

Further research is also needed to understand the role of the different information sources and the attention mechanisms in driving the performance improvements. Ablation studies or visualization techniques could provide more insights into the inner workings of the network.

Overall, CMRATT represents a promising advancement in accelerating cardiac MRI reconstruction, but additional validation and analysis would be helpful to fully assess its practical utility and limitations.

Conclusion

This paper presents a novel attention-based deep learning framework called CMRATT for accelerating cardiac MRI reconstruction. By adaptively fusing low-rank, image-space, and k-space information using attention mechanisms, CMRATT is able to produce high-quality cardiac cine images from heavily undersampled data, enabling single breath-hold imaging.

The results demonstrate significant improvements in reconstruction quality and speed compared to prior methods, which could lead to more patient-friendly and efficient cardiac MRI exams. While further research is needed to fully characterize the method's performance and practical considerations, CMRATT represents an important step forward in advancing MRI reconstruction capabilities for clinical applications.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Attention Incorporated Network for Sharing Low-rank, Image and K-space Information during MR Image Reconstruction to Achieve Single Breath-hold Cardiac Cine Imaging
Total Score

0

Attention Incorporated Network for Sharing Low-rank, Image and K-space Information during MR Image Reconstruction to Achieve Single Breath-hold Cardiac Cine Imaging

Siying Xu, Kerstin Hammernik, Andreas Lingg, Jens Kuebler, Patrick Krumm, Daniel Rueckert, Sergios Gatidis, Thomas Kuestner

Cardiac Cine Magnetic Resonance Imaging (MRI) provides an accurate assessment of heart morphology and function in clinical practice. However, MRI requires long acquisition times, with recent deep learning-based methods showing great promise to accelerate imaging and enhance reconstruction quality. Existing networks exhibit some common limitations that constrain further acceleration possibilities, including single-domain learning, reliance on a single regularization term, and equal feature contribution. To address these limitations, we propose to embed information from multiple domains, including low-rank, image, and k-space, in a novel deep learning network for MRI reconstruction, which we denote as A-LIKNet. A-LIKNet adopts a parallel-branch structure, enabling independent learning in the k-space and image domain. Coupled information sharing layers realize the information exchange between domains. Furthermore, we introduce attention mechanisms into the network to assign greater weights to more critical coils or important temporal frames. Training and testing were conducted on an in-house dataset, including 91 cardiovascular patients and 38 healthy subjects scanned with 2D cardiac Cine using retrospective undersampling. Additionally, we evaluated A-LIKNet on the real-time 8x prospectively undersampled data from the OCMR dataset. The results demonstrate that our proposed A-LIKNet outperforms existing methods and provides high-quality reconstructions. The network can effectively reconstruct highly retrospectively undersampled dynamic MR images up to 24x accelerations, indicating its potential for single breath-hold imaging.

Read more

7/4/2024

Accelerating Cardiac MRI Reconstruction with CMRatt: An Attention-Driven Approach
Total Score

0

Accelerating Cardiac MRI Reconstruction with CMRatt: An Attention-Driven Approach

Anam Hashmi, Julia Dietlmeier, Kathleen M. Curran, Noel E. O'Connor

Cine cardiac magnetic resonance (CMR) imaging is recognised as the benchmark modality for the comprehensive assessment of cardiac function. Nevertheless, the acquisition process of cine CMR is considered as an impediment due to its prolonged scanning time. One commonly used strategy to expedite the acquisition process is through k-space undersampling, though it comes with a drawback of introducing aliasing effects in the reconstructed image. Lately, deep learning-based methods have shown remarkable results over traditional approaches in rapidly achieving precise CMR reconstructed images. This study aims to explore the untapped potential of attention mechanisms incorporated with a deep learning model within the context of the CMR reconstruction problem. We are motivated by the fact that attention has proven beneficial in downstream tasks such as image classification and segmentation, but has not been systematically analysed in the context of CMR reconstruction. Our primary goal is to identify the strengths and potential limitations of attention algorithms when integrated with a convolutional backbone model such as a U-Net. To achieve this, we benchmark different state-of-the-art spatial and channel attention mechanisms on the CMRxRecon dataset and quantitatively evaluate the quality of reconstruction using objective metrics. Furthermore, inspired by the best performing attention mechanism, we propose a new, simple yet effective, attention pipeline specifically optimised for the task of cardiac image reconstruction that outperforms other state-of-the-art attention methods. The layer and model code will be made publicly available.

Read more

4/11/2024

🖼️

Total Score

0

New!Joint image reconstruction and segmentation of real-time cardiac MRI in free-breathing using a model based on disentangled representation learning

Tobias Wech, Oliver Schad, Simon Sauer, Jonas Kleineisel, Nils Petri, Peter Nordbeck, Thorsten A. Bley, Bettina Bae{ss}ler, Bernhard Petritsch, Julius F. Heidenreich

A joint image reconstruction and segmentation approach based on disentangled representation learning was trained to enable cardiac cine MR imaging in real-time and under free-breathing. An exploratory feasibility study tested the proposed method in undersampled real-time acquisitions based on an in-house developed spiral bSSFP pulse sequence in eight healthy participants and five patients with intermittent atrial fibrillation. Images and predicted LV segmentations were compared to the reference standard of ECG-gated segmented Cartesian cine in repeated breath-holds and corresponding manual segmentation. On a 5-point Likert scale, image quality of the real-time breath-hold approach and Cartesian cine was comparable in healthy participants (RT-BH: 1.99 $pm$ .98, Cartesian: 1.94 $pm$ .86, p=.052), but slightly inferior in free-breathing (RT-FB: 2.40 $pm$ .98, p<.001). In patients with arrhythmia, image quality from both real-time approaches was favourable (RT-BH: 2.10 $pm$ 1.28, p<.001, RT-FB: 2.40 $pm$ 1.13, p<.001, Cartesian: 2.68 $pm$ 1.13). Intra-observer reliability was good (ICC=.77, 95%-confidence interval [.75, .79], p<.001). In functional analysis, a positive bias was observed for ejection fractions derived from the proposed model compared to the clinical reference standard (RT-BH mean EF: 58.5 $pm$ 5.6%, bias: +3.47%, 95%-confidence interval [-.86, 7.79%], RT-FB mean: 57.9 $pm$ 10.6%, bias: +1.45%, [-3.02, 5.91%], Cartesian mean: 54.9 $pm$ 6.7%). The introduced real-time MR imaging technique is capable of acquiring high-quality cardiac cine data in 1-2 minutes without the need for ECG gating and breath-holds. It thus offers a promising alternative to the current clinical practice of segmented acquisition, with shorter scan times, higher patient comfort and increased robustness to arrhythmia and patient incompliance.

Read more

9/16/2024

Relaxometry Guided Quantitative Cardiac Magnetic Resonance Image Reconstruction
Total Score

0

Relaxometry Guided Quantitative Cardiac Magnetic Resonance Image Reconstruction

Yidong Zhao, Yi Zhang, Qian Tao

Deep learning-based methods have achieved prestigious performance for magnetic resonance imaging (MRI) reconstruction, enabling fast imaging for many clinical applications. Previous methods employ convolutional networks to learn the image prior as the regularization term. In quantitative MRI, the physical model of nuclear magnetic resonance relaxometry is known, providing additional prior knowledge for image reconstruction. However, traditional reconstruction networks are limited to learning the spatial domain prior knowledge, ignoring the relaxometry prior. Therefore, we propose a relaxometry-guided quantitative MRI reconstruction framework to learn the spatial prior from data and the relaxometry prior from MRI physics. Additionally, we also evaluated the performance of two popular reconstruction backbones, namely, recurrent variational networks (RVN) and variational networks (VN) with U- Net. Experiments demonstrate that the proposed method achieves highly promising results in quantitative MRI reconstruction.

Read more

5/2/2024