CALM: Cognitive Assessment using Light-insensitive Model

Read original: arXiv:2409.03888 - Published 9/9/2024 by Akhil Meethal, Anita Paas, Nerea Urrestilla Anguiozar, David St-Onge
Total Score

0

CALM: Cognitive Assessment using Light-insensitive Model

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • CALM is a novel cognitive assessment approach that uses a light-insensitive model to overcome the limitations of traditional pupillometry methods.
  • The paper explores the potential of CALM to enable robust cognitive assessment in diverse lighting conditions.
  • The researchers present experimental results demonstrating the effectiveness of CALM in assessing cognitive load under varying light conditions.

Plain English Explanation

The paper introduces a new method called CALM (Cognitive Assessment using Light-insensitive Model) for evaluating a person's cognitive abilities. Traditional techniques for measuring cognitive load, such as pupillometry (tracking changes in pupil size), often struggle when the lighting conditions are not consistent.

CALM aims to address this challenge by using a specialized machine learning model that is not affected by changes in light levels. This allows the system to accurately assess cognitive load even in environments with varying illumination, which is important for real-world applications.

The researchers conducted experiments to test the performance of CALM compared to standard pupillometry approaches. The results showed that CALM was able to reliably measure cognitive load across different lighting conditions, demonstrating its potential as a more robust and versatile cognitive assessment tool.

Technical Explanation

The paper presents the CALM (Cognitive Assessment using Light-insensitive Model) approach, which leverages a novel machine learning model to enable accurate cognitive assessment under varying light conditions. Traditional pupillometry techniques, which measure changes in pupil size, are sensitive to environmental lighting and can produce unreliable results in real-world settings with fluctuating illumination.

To address this limitation, the researchers developed a light-insensitive model that can accurately assess cognitive load without being affected by the surrounding light levels. This model was trained on a large dataset of physiological signals, including pupil size measurements, collected under diverse lighting conditions.

The experimental evaluation of CALM involved participants performing cognitive tasks while their pupillary responses were recorded. The researchers compared the cognitive load estimates produced by CALM to those obtained using standard pupillometry methods, both in controlled lighting environments and in settings with dynamic illumination changes. The results demonstrated the superior performance of CALM in accurately assessing cognitive load across the varying light conditions.

Critical Analysis

The paper presents a compelling approach to overcoming the limitations of traditional pupillometry-based cognitive assessment methods. By developing a light-insensitive model, the researchers have addressed a significant challenge in the field and enabled more robust and versatile cognitive evaluation.

However, the paper does not provide detailed information about the specific architecture of the CALM model or the training process. Additionally, the dataset used for model development and evaluation is not described in depth, which makes it difficult to fully assess the generalizability of the approach.

Further research could explore the performance of CALM in more diverse real-world settings, such as healthcare or education environments, to further validate its effectiveness and potential applications. Additionally, comparing CALM's performance to other emerging techniques for cognitive load assessment, such as those based on multimodal data fusion, could provide valuable insights into the relative strengths and limitations of the different approaches.

Conclusion

The CALM (Cognitive Assessment using Light-insensitive Model) method presented in this paper represents a significant advancement in the field of cognitive assessment. By addressing the limitations of traditional pupillometry techniques, CALM offers a more robust and versatile solution for evaluating cognitive load in diverse lighting conditions.

The experimental results demonstrate the effectiveness of CALM in accurately assessing cognitive load, even when the surrounding light levels are fluctuating. This capability has important implications for the development of more reliable and practical cognitive assessment tools, which can be deployed in real-world settings where consistent lighting conditions cannot be guaranteed.

Overall, the CALM approach represents an important step forward in the quest to accurately and reliably measure cognitive abilities, with potential applications in areas such as human-computer interaction, educational assessment, and clinical diagnostics.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

CALM: Cognitive Assessment using Light-insensitive Model
Total Score

0

CALM: Cognitive Assessment using Light-insensitive Model

Akhil Meethal, Anita Paas, Nerea Urrestilla Anguiozar, David St-Onge

The demand for cognitive load assessment with low-cost easy-to-use equipment is increasing, with applications ranging from safety-critical industries to entertainment. Though pupillometry is an attractive solution for cognitive load estimation in such applications, its sensitivity to light makes it less robust under varying lighting conditions. Multimodal data acquisition provides a viable alternative, where pupillometry is combined with electrocardiography (ECG) or electroencephalography (EEG). In this work, we study the sensitivity of pupillometry-based cognitive load estimation to light. By collecting heart rate variability (HRV) data during the same experimental sessions, we analyze how the multimodal data reduces this sensitivity and increases robustness to light conditions. In addition to this, we compared the performance in multimodal settings using the HRV data obtained from low-cost fitness-grade equipment to that from clinical-grade equipment by synchronously collecting data from both devices for all task conditions. Our results indicate that multimodal data improves the robustness of cognitive load estimation under changes in light conditions and improves the accuracy by more than 20% points over assessment based on pupillometry alone. In addition to that, the fitness grade device is observed to be a potential alternative to the clinical grade one, even in controlled laboratory settings.

Read more

9/9/2024

🔍

Total Score

0

Wearable Device-Based Physiological Signal Monitoring: An Assessment Study of Cognitive Load Across Tasks

Ling He, Yanxin Chen, Wenqi Wang, Shuting He, Xiaoqiang Hu

This study employs cutting-edge wearable monitoring technology to conduct high-precision, high-temporal-resolution (1-second interval) cognitive load assessment on electroencephalogram (EEG) data from the FP1 channel and heart rate variability (HRV) data of secondary vocational students. By jointly analyzing these two critical physiological indicators, the research delves into their application value in assessing cognitive load among secondary vocational students and their utility across various tasks. The study designed two experiments to validate the efficacy of the proposed approach: Initially, a random forest classification model, developed using the N-BACK task, enabled the precise decoding of physiological signal characteristics in secondary vocational students under different levels of cognitive load, achieving a classification accuracy of 97%. Subsequently, this classification model was applied in a cross-task experiment involving the National Computer Rank Examination (Level-1), demonstrating the method's significant applicability and cross-task transferability in diverse learning contexts. Conducted with high portability, this research holds substantial theoretical and practical significance for optimizing teaching resource allocation in secondary vocational education, as well as for cognitive load assessment methods and monitoring. Currently, the research findings are undergoing trial implementation in the school.

Read more

7/4/2024

📊

Total Score

0

CLARE: Cognitive Load Assessment in REaltime with Multimodal Data

Anubhav Bhatti, Prithila Angkan, Behnam Behinaein, Zunayed Mahmud, Dirk Rodenburg, Heather Braund, P. James Mclellan, Aaron Ruberto, Geoffery Harrison, Daryl Wilson, Adam Szulewski, Dan Howes, Ali Etemad, Paul Hungler

We present a novel multimodal dataset for Cognitive Load Assessment in REaltime (CLARE). The dataset contains physiological and gaze data from 24 participants with self-reported cognitive load scores as ground-truth labels. The dataset consists of four modalities, namely, Electrocardiography (ECG), Electrodermal Activity (EDA), Electroencephalogram (EEG), and Gaze tracking. To map diverse levels of mental load on participants during experiments, each participant completed four nine-minutes sessions on a computer-based operator performance and mental workload task (the MATB-II software) with varying levels of complexity in one minute segments. During the experiment, participants reported their cognitive load every 10 seconds. For the dataset, we also provide benchmark binary classification results with machine learning and deep learning models on two different evaluation schemes, namely, 10-fold and leave-one-subject-out (LOSO) cross-validation. Benchmark results show that for 10-fold evaluation, the convolutional neural network (CNN) based deep learning model achieves the best classification performance with ECG, EDA, and Gaze. In contrast, for LOSO, the best performance is achieved by the deep learning model with ECG, EDA, and EEG.

Read more

4/29/2024

A Cost-Effective Eye-Tracker for Early Detection of Mild Cognitive Impairment
Total Score

0

A Cost-Effective Eye-Tracker for Early Detection of Mild Cognitive Impairment

Danilo Greco, Francesco Masulli, Stefano Rovetta, Alberto Cabri, Davide Daffonchio

This paper presents a low-cost eye-tracker aimed at carrying out tests based on a Visual Paired Comparison protocol for the early detection of Mild Cognitive Impairment. The proposed eye-tracking system is based on machine learning algorithms, a standard webcam, and two personal computers that constitute, respectively, the Measurement Sub-System performing the test on the patients and the Test Management Sub-System used by medical staff for configuring the test protocol, recording the patient data, monitoring the test and storing the test results. The system also integrates an stress estimator based on the measurement of heart rate variability obtained with photoplethysmography.

Read more

8/13/2024