Deep Learning Based Apparent Diffusion Coefficient Map Generation1 from Multi-parametric MR Images for Patients with Diffuse Gliomas

Read original: arXiv:2407.02616 - Published 7/8/2024 by Zach Eidex, Mojtaba Safari, Jacob Wynne, Richard L. J. Qiu, Tonghe Wang, David Viar Hernandez, Hui-Kuo Shu, Hui Mao, Xiaofeng Yang
Total Score

0

🤿

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper proposes a deep learning framework called the Multiparametric Residual Vision Transformer (MPR-ViT) to synthesize Apparent Diffusion Coefficient (ADC) maps from multi-parametric Magnetic Resonance (MR) images.
  • ADC maps provide functional information about water molecule movement in tissues, but acquiring them can be time-consuming and subject to artifacts, leading to inaccurate measurements.
  • The MPR-ViT model leverages the long-range context of Vision Transformer (ViT) layers and the precision of convolutional operators, with residual blocks to increase the model's representational power.
  • The model was trained and evaluated on a dataset of 501 glioma cases, with the goal of producing high-quality synthetic ADC maps from T1-weighted and T2-FLAIR MRI.

Plain English Explanation

Magnetic Resonance Imaging (MRI) is a powerful medical imaging technique that can provide detailed information about the structure and function of the human body. One type of MRI, called Diffusion-Weighted Imaging (DWI), can measure the movement of water molecules within tissues, which can give insights into the health and properties of those tissues.

The measurements from DWI, called Apparent Diffusion Coefficient (ADC) maps, are particularly useful for diagnosing and monitoring certain medical conditions, such as cancer. However, acquiring ADC maps can be a time-consuming process and is prone to artifacts, which can lead to inaccurate measurements.

To address this issue, the researchers in this study developed a deep learning framework called the Multiparametric Residual Vision Transformer (MPR-ViT). This model is designed to synthesize, or generate, high-quality ADC maps from more readily available MRI images, such as T1-weighted and T2-FLAIR scans.

The key innovation of the MPR-ViT model is that it combines the strengths of two different deep learning approaches: the long-range context understanding of Vision Transformers and the precision of convolutional neural networks. The model also uses residual blocks to further improve its ability to accurately synthesize the ADC maps.

The researchers tested the MPR-ViT model on a dataset of 501 glioma (brain tumor) cases, and found that it was able to generate ADC maps that closely matched the ground truth data, outperforming other state-of-the-art models. This suggests that the MPR-ViT could be a useful tool for clinicians, as it could provide high-quality ADC maps without the time and artifact issues associated with direct DWI acquisition.

Technical Explanation

The researchers proposed the Multiparametric Residual Vision Transformer (MPR-ViT) model to synthesize Apparent Diffusion Coefficient (ADC) maps from multi-parametric Magnetic Resonance (MR) images, specifically T1-weighted and T2-FLAIR scans.

The MPR-ViT architecture combines the strengths of Vision Transformers (ViT) and convolutional neural networks. The ViT layers capture long-range contextual information, while the convolutional operators provide precise, local feature extraction. Residual blocks are used throughout the network to significantly increase the model's representational power.

The researchers trained and evaluated the MPR-ViT model on a dataset of 501 glioma cases from a publicly available source. The dataset included preprocessed ADC maps, which were used as the ground truth for model training and evaluation. The patients were divided into training (N=400), validation (N=50), and test (N=51) sets.

The performance of the MPR-ViT model was assessed using several metrics, including Peak Signal-to-Noise Ratio (PSNR), Mean Squared Error (MSE), and Structural Similarity Index (SSIM). The results showed that the MPR-ViT model achieved a PSNR of 31.0 ± 2.1, MSE of 0.009 ± 0.0005, and SSIM of 0.950 ± 0.015 when using T1-weighted and T2-FLAIR MRI as inputs.

The researchers also conducted ablation studies to evaluate the relative impact of each input sequence on the model's performance. Both qualitative and quantitative results indicated that the proposed MPR-ViT model outperformed the Vision Convolutional Transformer (VCT) and Residual Vision Transformer (ResViT) models in synthesizing high-quality ADC maps from the provided multi-parametric MRI data.

Critical Analysis

The researchers have presented a promising deep learning framework for synthesizing high-quality ADC maps from multi-parametric MRI data. The use of the Vision Transformer architecture, combined with convolutional operators and residual blocks, appears to be an effective approach for this task.

One potential limitation of the study is the relatively small size of the dataset, with only 501 glioma cases. While the researchers did split the dataset into training, validation, and test sets, a larger and more diverse dataset would help to further validate the model's performance and generalizability.

Additionally, the researchers did not explore the model's performance on other types of brain lesions or pathologies beyond glioma. It would be valuable to assess the MPR-ViT's ability to synthesize accurate ADC maps for a broader range of medical conditions.

Another area for further research could be the exploration of different input modalities beyond T1-weighted and T2-FLAIR MRI. The incorporation of additional MRI sequences, such as Diffusion Tensor Imaging or Perfusion-Weighted Imaging, may further improve the model's ability to generate high-quality ADC maps.

Overall, the proposed MPR-ViT model appears to be a promising approach for addressing the limitations of direct DWI acquisition and the generation of ADC maps. The researchers have demonstrated the model's strong performance, and the findings have the potential to positively impact clinical practice, particularly in the diagnosis and monitoring of brain diseases.

Conclusion

This study presents a novel deep learning framework called the Multiparametric Residual Vision Transformer (MPR-ViT) for synthesizing high-quality Apparent Diffusion Coefficient (ADC) maps from multi-parametric Magnetic Resonance (MR) images. The key innovation of the MPR-ViT model is its ability to leverage the long-range context understanding of Vision Transformers and the precision of convolutional operators, further enhanced by the use of residual blocks.

The researchers demonstrated the effectiveness of the MPR-ViT model on a dataset of 501 glioma cases, where it outperformed other state-of-the-art models in generating ADC maps that closely matched the ground truth data. These synthetic ADC maps could be particularly useful for disease diagnosis and monitoring, especially when direct Diffusion-Weighted Imaging (DWI) acquisition is not feasible or is prone to artifacts.

The findings of this study suggest that the MPR-ViT model has the potential to significantly improve the availability and quality of ADC maps in clinical practice, ultimately leading to better patient care and outcomes. However, further research is needed to explore the model's performance on a wider range of medical conditions and the incorporation of additional MRI modalities to enhance the synthesis of ADC maps.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🤿

Total Score

0

Deep Learning Based Apparent Diffusion Coefficient Map Generation1 from Multi-parametric MR Images for Patients with Diffuse Gliomas

Zach Eidex, Mojtaba Safari, Jacob Wynne, Richard L. J. Qiu, Tonghe Wang, David Viar Hernandez, Hui-Kuo Shu, Hui Mao, Xiaofeng Yang

Purpose: Apparent diffusion coefficient (ADC) maps derived from diffusion weighted (DWI) MRI provides functional measurements about the water molecules in tissues. However, DWI is time consuming and very susceptible to image artifacts, leading to inaccurate ADC measurements. This study aims to develop a deep learning framework to synthesize ADC maps from multi-parametric MR images. Methods: We proposed the multiparametric residual vision transformer model (MPR-ViT) that leverages the long-range context of ViT layers along with the precision of convolutional operators. Residual blocks throughout the network significantly increasing the representational power of the model. The MPR-ViT model was applied to T1w and T2- fluid attenuated inversion recovery images of 501 glioma cases from a publicly available dataset including preprocessed ADC maps. Selected patients were divided into training (N=400), validation (N=50) and test (N=51) sets, respectively. Using the preprocessed ADC maps as ground truth, model performance was evaluated and compared against the Vision Convolutional Transformer (VCT) and residual vision transformer (ResViT) models. Results: The results are as follows using T1w + T2-FLAIR MRI as inputs: MPR-ViT - PSNR: 31.0 +/- 2.1, MSE: 0.009 +/- 0.0005, SSIM: 0.950 +/- 0.015. In addition, ablation studies showed the relative impact on performance of each input sequence. Both qualitative and quantitative results indicate that the proposed MR- ViT model performs favorably against the ground truth data. Conclusion: We show that high-quality ADC maps can be synthesized from structural MRI using a MPR- VCT model. Our predicted images show better conformality to the ground truth volume than ResViT and VCT predictions. These high-quality synthetic ADC maps would be particularly useful for disease diagnosis and intervention, especially when ADC maps have artifacts or are unavailable.

Read more

7/8/2024

🛸

Total Score

0

T1-contrast Enhanced MRI Generation from Multi-parametric MRI for Glioma Patients with Latent Tumor Conditioning

Zach Eidex, Mojtaba Safari, Richard L. J. Qiu, David S. Yu, Hui-Kuo Shu, Hui Mao, Xiaofeng Yang

Objective: Gadolinium-based contrast agents (GBCAs) are commonly used in MRI scans of patients with gliomas to enhance brain tumor characterization using T1-weighted (T1W) MRI. However, there is growing concern about GBCA toxicity. This study develops a deep-learning framework to generate T1-postcontrast (T1C) from pre-contrast multiparametric MRI. Approach: We propose the tumor-aware vision transformer (TA-ViT) model that predicts high-quality T1C images. The predicted tumor region is significantly improved (P < .001) by conditioning the transformer layers from predicted segmentation maps through adaptive layer norm zero mechanism. The predicted segmentation maps were generated with the multi-parametric residual (MPR) ViT model and transformed into a latent space to produce compressed, feature-rich representations. The TA-ViT model predicted T1C MRI images of 501 glioma cases. Selected patients were split into training (N=400), validation (N=50), and test (N=51) sets. Main Results: Both qualitative and quantitative results demonstrate that the TA-ViT model performs superior against the benchmark MRP-ViT model. Our method produces synthetic T1C MRI with high soft tissue contrast and more accurately reconstructs both the tumor and whole brain volumes. The synthesized T1C images achieved remarkable improvements in both tumor and healthy tissue regions compared to the MRP-ViT model. For healthy tissue and tumor regions, the results were as follows: NMSE: 8.53 +/- 4.61E-4; PSNR: 31.2 +/- 2.2; NCC: 0.908 +/- .041 and NMSE: 1.22 +/- 1.27E-4, PSNR: 41.3 +/- 4.7, and NCC: 0.879 +/- 0.042, respectively. Significance: The proposed method generates synthetic T1C images that closely resemble real T1C images. Future development and application of this approach may enable contrast-agent-free MRI for brain tumor patients, eliminating the risk of GBCA toxicity and simplifying the MRI scan protocol.

Read more

9/4/2024

🔮

Total Score

0

Improving Breast Cancer Grade Prediction with Multiparametric MRI Created Using Optimized Synthetic Correlated Diffusion Imaging

Chi-en Amy Tai, Alexander Wong

Breast cancer was diagnosed for over 7.8 million women between 2015 to 2020. Grading plays a vital role in breast cancer treatment planning. However, the current tumor grading method involves extracting tissue from patients, leading to stress, discomfort, and high medical costs. A recent paper leveraging volumetric deep radiomic features from synthetic correlated diffusion imaging (CDI$^s$) for breast cancer grade prediction showed immense promise for noninvasive methods for grading. Motivated by the impact of CDI$^s$ optimization for prostate cancer delineation, this paper examines using optimized CDI$^s$ to improve breast cancer grade prediction. We fuse the optimized CDI$^s$ signal with diffusion-weighted imaging (DWI) to create a multiparametric MRI for each patient. Using a larger patient cohort and training across all the layers of a pretrained MONAI model, we achieve a leave-one-out cross-validation accuracy of 95.79%, over 8% higher compared to that previously reported.

Read more

5/14/2024

🤿

Total Score

0

Deep Learning-based Unsupervised Domain Adaptation via a Unified Model for Prostate Lesion Detection Using Multisite Bi-parametric MRI Datasets

Hao Li, Han Liu, Heinrich von Busch, Robert Grimm, Henkjan Huisman, Angela Tong, David Winkel, Tobias Penzkofer, Ivan Shabunin, Moon Hyung Choi, Qingsong Yang, Dieter Szolar, Steven Shea, Fergus Coakley, Mukesh Harisinghani, Ipek Oguz, Dorin Comaniciu, Ali Kamen, Bin Lou

Our hypothesis is that UDA using diffusion-weighted images, generated with a unified model, offers a promising and reliable strategy for enhancing the performance of supervised learning models in multi-site prostate lesion detection, especially when various b-values are present. This retrospective study included data from 5,150 patients (14,191 samples) collected across nine different imaging centers. A novel UDA method using a unified generative model was developed for multi-site PCa detection. This method translates diffusion-weighted imaging (DWI) acquisitions, including apparent diffusion coefficient (ADC) and individual DW images acquired using various b-values, to align with the style of images acquired using b-values recommended by Prostate Imaging Reporting and Data System (PI-RADS) guidelines. The generated ADC and DW images replace the original images for PCa detection. An independent set of 1,692 test cases (2,393 samples) was used for evaluation. The area under the receiver operating characteristic curve (AUC) was used as the primary metric, and statistical analysis was performed via bootstrapping. For all test cases, the AUC values for baseline SL and UDA methods were 0.73 and 0.79 (p=3, and 0.77 and 0.80 (p=4 PCa lesions. In the 361 test cases under the most unfavorable image acquisition setting, the AUC values for baseline SL and UDA were 0.49 and 0.76 (p=3, and 0.50 and 0.77 (p=4 PCa lesions. The results indicate the proposed UDA with generated images improved the performance of SL methods in multi-site PCa lesion detection across datasets with various b values, especially for images acquired with significant deviations from the PI-RADS recommended DWI protocol (e.g. with an extremely high b-value).

Read more

8/12/2024