Diffusion Schrodinger Bridge Models for High-Quality MR-to-CT Synthesis for Head and Neck Proton Treatment Planning

Read original: arXiv:2404.11741 - Published 7/2/2024 by Muheng Li, Xia Li, Sairos Safai, Damien Weber, Antony Lomax, Ye Zhang
Total Score

0

Diffusion Schrodinger Bridge Models for High-Quality MR-to-CT Synthesis for Head and Neck Proton Treatment Planning

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents a novel approach for synthesizing high-quality CT scans from MRI data using diffusion Schrödinger bridge models for head and neck proton treatment planning.
  • The proposed method aims to improve the accuracy and fidelity of MR-to-CT synthesis, which is crucial for radiation therapy planning and dose calculation.
  • The researchers leverage the strengths of diffusion Schrödinger bridge models, a powerful class of generative models, to generate realistic CT images from MRI inputs.

Plain English Explanation

Doctors often need to plan radiation therapy for cancer patients by using CT (computed tomography) scans of the patient's body. However, sometimes it's difficult or expensive to get high-quality CT scans, especially for certain parts of the body like the head and neck. In these cases, the doctors may try to generate a CT scan from an MRI (magnetic resonance imaging) scan instead.

This paper introduces a new method that uses a type of machine learning called "diffusion Schrödinger bridge models" to create very realistic and accurate CT scans from MRI scans of the head and neck area. The key idea is to train the model to learn the relationship between MRI and CT scans, so that it can then generate a high-quality CT scan given just an MRI scan as input.

This is important for radiation therapy planning because the doctors need accurate 3D information about the patient's anatomy to ensure the radiation is delivered safely and effectively. By using this new technique, doctors may be able to plan radiation treatments more accurately without needing expensive CT scans.

Technical Explanation

The authors propose using diffusion Schrödinger bridge models for the task of MR-to-CT synthesis for head and neck proton treatment planning. Diffusion Schrödinger bridge models are a powerful class of generative models that can capture complex data distributions.

The key elements of the proposed approach include:

  1. Data collection: The researchers curated a dataset of paired MRI and CT scans of the head and neck region from cancer patients.
  2. Model architecture: They designed a diffusion Schrödinger bridge model that takes an MRI scan as input and generates a corresponding high-quality CT scan as output.
  3. Training procedure: The model was trained on the paired MRI-CT dataset using the diffusion Schrödinger bridge framework, which encourages the generated CT scans to be realistic and anatomically consistent with the input MRI.

The authors demonstrate the effectiveness of their approach through extensive experiments, showing that the generated CT scans achieve superior quality and fidelity compared to other state-of-the-art MR-to-CT synthesis methods. This advance could significantly improve the accuracy of radiation therapy planning for head and neck cancer patients.

Critical Analysis

The paper presents a well-designed and thoroughly evaluated approach for MR-to-CT synthesis using diffusion Schrödinger bridge models. However, there are a few potential limitations and areas for further research:

  1. The dataset size: The authors mention that the dataset used for training and evaluation is relatively small, as collecting high-quality paired MRI-CT scans can be challenging. Larger datasets may be needed to fully unleash the potential of the proposed method.

  2. Generalization to other anatomical regions: The focus of this work is on the head and neck region, and it's unclear how well the method would generalize to other parts of the body. Further investigation is needed to assess the versatility of the approach.

  3. Computational complexity: Diffusion Schrödinger bridge models can be computationally intensive, especially during inference. The authors could explore ways to optimize the model's efficiency for practical clinical applications.

  4. Interpretability: As with many deep learning models, the internal workings of the diffusion Schrödinger bridge model may be difficult to interpret. Providing more insights into how the model achieves such high-quality synthesis could enhance the understanding and trust in the approach.

Despite these potential limitations, the paper presents a significant advance in the field of MR-to-CT synthesis, with important implications for improving the accuracy and accessibility of radiation therapy planning.

Conclusion

This paper introduces a novel approach for synthesizing high-quality CT scans from MRI data using diffusion Schrödinger bridge models, with a focus on head and neck proton treatment planning. The proposed method demonstrates impressive results in generating realistic and anatomically accurate CT images from MRI inputs, which could greatly benefit radiation therapy planning and dose calculation for cancer patients.

The researchers leverage the strengths of diffusion Schrödinger bridge models, a powerful class of generative models, to capture the complex relationship between MRI and CT data. This advance has the potential to improve the accessibility and accuracy of radiation therapy planning, especially in cases where obtaining high-quality CT scans is challenging or expensive.

While the paper presents a significant contribution, further research is needed to address potential limitations, such as the dataset size, generalization to other anatomical regions, computational complexity, and model interpretability. Nonetheless, this work represents an important step forward in the field of medical image synthesis and its applications in cancer treatment.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Diffusion Schrodinger Bridge Models for High-Quality MR-to-CT Synthesis for Head and Neck Proton Treatment Planning
Total Score

0

Diffusion Schrodinger Bridge Models for High-Quality MR-to-CT Synthesis for Head and Neck Proton Treatment Planning

Muheng Li, Xia Li, Sairos Safai, Damien Weber, Antony Lomax, Ye Zhang

In recent advancements in proton therapy, MR-based treatment planning is gaining momentum to minimize additional radiation exposure compared to traditional CT-based methods. This transition highlights the critical need for accurate MR-to-CT image synthesis, which is essential for precise proton dose calculations. Our research introduces the Diffusion Schrodinger Bridge Models (DSBM), an innovative approach for high-quality MR-to-CT synthesis. DSBM learns the nonlinear diffusion processes between MR and CT data distributions. This method improves upon traditional diffusion models by initiating synthesis from the prior distribution rather than the Gaussian distribution, enhancing both generation quality and efficiency. We validated the effectiveness of DSBM on a head and neck cancer dataset, demonstrating its superiority over traditional image synthesis methods through both image-level and dosimetric-level evaluations. The effectiveness of DSBM in MR-based proton treatment planning highlights its potential as a valuable tool in various clinical scenarios.

Read more

7/2/2024

Integrating Deep Unfolding with Direct Diffusion Bridges for Computed Tomography Reconstruction
Total Score

0

New!Integrating Deep Unfolding with Direct Diffusion Bridges for Computed Tomography Reconstruction

Herman Verinaz-Jadan, Su Yan

Computed Tomography (CT) is widely used in healthcare for detailed imaging. However, Low-dose CT, despite reducing radiation exposure, often results in images with compromised quality due to increased noise. Traditional methods, including preprocessing, post-processing, and model-based approaches that leverage physical principles, are employed to improve the quality of image reconstructions from noisy projections or sinograms. Recently, deep learning has significantly advanced the field, with diffusion models outperforming both traditional methods and other deep learning approaches. These models effectively merge deep learning with physics, serving as robust priors for the inverse problem in CT. However, they typically require prolonged computation times during sampling. This paper introduces the first approach to merge deep unfolding with Direct Diffusion Bridges (DDBs) for CT, integrating the physics into the network architecture and facilitating the transition from degraded to clean images by bypassing excessively noisy intermediate stages commonly encountered in diffusion models. Moreover, this approach includes a tailored training procedure that eliminates errors typically accumulated during sampling. The proposed approach requires fewer sampling steps and demonstrates improved fidelity metrics, outperforming many existing state-of-the-art techniques.

Read more

9/17/2024

Slice-Consistent 3D Volumetric Brain CT-to-MRI Translation with 2D Brownian Bridge Diffusion Model
Total Score

0

Slice-Consistent 3D Volumetric Brain CT-to-MRI Translation with 2D Brownian Bridge Diffusion Model

Kyobin Choo, Youngjun Jun, Mijin Yun, Seong Jae Hwang

In neuroimaging, generally, brain CT is more cost-effective and accessible imaging option compared to MRI. Nevertheless, CT exhibits inferior soft-tissue contrast and higher noise levels, yielding less precise structural clarity. In response, leveraging more readily available CT to construct its counterpart MRI, namely, medical image-to-image translation (I2I), serves as a promising solution. Particularly, while diffusion models (DMs) have recently risen as a powerhouse, they also come with a few practical caveats for medical I2I. First, DMs' inherent stochasticity from random noise sampling cannot guarantee consistent MRI generation that faithfully reflects its CT. Second, for 3D volumetric images which are prevalent in medical imaging, naively using 2D DMs leads to slice inconsistency, e.g., abnormal structural and brightness changes. While 3D DMs do exist, significant training costs and data dependency bring hesitation. As a solution, we propose novel style key conditioning (SKC) and inter-slice trajectory alignment (ISTA) sampling for the 2D Brownian bridge diffusion model. Specifically, SKC ensures a consistent imaging style (e.g., contrast) across slices, and ISTA interconnects the independent sampling of each slice, deterministically achieving style and shape consistent 3D CT-to-MRI translation. To the best of our knowledge, this study is the first to achieve high-quality 3D medical I2I based only on a 2D DM with no extra architectural models. Our experimental results show superior 3D medical I2I than existing 2D and 3D baselines, using in-house CT-MRI dataset and BraTS2023 FLAIR-T1 MRI dataset.

Read more

7/9/2024

Simplified Diffusion Schrodinger Bridge
Total Score

0

Simplified Diffusion Schrodinger Bridge

Zhicong Tang, Tiankai Hang, Shuyang Gu, Dong Chen, Baining Guo

This paper introduces a novel theoretical simplification of the Diffusion Schrodinger Bridge (DSB) that facilitates its unification with Score-based Generative Models (SGMs), addressing the limitations of DSB in complex data generation and enabling faster convergence and enhanced performance. By employing SGMs as an initial solution for DSB, our approach capitalizes on the strengths of both frameworks, ensuring a more efficient training process and improving the performance of SGM. We also propose a reparameterization technique that, despite theoretical approximations, practically improves the network's fitting capabilities. Our extensive experimental evaluations confirm the effectiveness of the simplified DSB, demonstrating its significant improvements. We believe the contributions of this work pave the way for advanced generative modeling.

Read more

8/14/2024