Efficient Patient Fine-Tuned Seizure Detection with a Tensor Kernel Machine

Read original: arXiv:2408.00437 - Published 8/2/2024 by Seline J. S. de Rooij, Frederiek Wesel, Borb'ala Hunyadi
Total Score

0

🔎

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Efficient patient-specific seizure detection using a tensor kernel machine
  • Leverages transfer learning to adapt a pre-trained model to individual patient data
  • Aims to achieve accurate seizure detection with minimal training data from the target patient

Plain English Explanation

The paper presents a method for efficient patient-tuned seizure detection using a tensor kernel machine. The key idea is to take a pre-trained model and fine-tune it on a small amount of data from the target patient, rather than training a new model from scratch.

This transfer learning approach allows the model to leverage general patterns learned from a large dataset, while also adapting to the unique characteristics of the individual patient's seizures. The goal is to achieve accurate seizure detection with minimal training data from the target patient, making the system more efficient and practical for real-world deployment.

Technical Explanation

The paper describes a tensor kernel machine as the underlying classification model. This type of machine learning model can effectively capture complex patterns in high-dimensional data, such as the multivariate time series data from electroencephalography (EEG) recordings.

The authors first train the tensor kernel machine on a large, general dataset of EEG recordings. They then fine-tune the model on a small amount of data from the target patient, updating the model's parameters to specialize it for that individual's seizure patterns. This transfer learning approach allows the model to achieve high accuracy with minimal patient-specific training data.

The authors evaluate their method on real-world EEG datasets and demonstrate that it outperforms alternative approaches, both in terms of seizure detection accuracy and the amount of patient-specific data required for training.

Critical Analysis

The paper provides a compelling approach to the challenge of patient-specific seizure detection, which is an important problem in clinical neurology. The use of transfer learning to adapt a pre-trained model to individual patients is a sensible strategy, as it can leverage general knowledge while still capturing patient-specific characteristics.

However, the paper does not address certain limitations or potential concerns. For example, it does not discuss the performance of the method on patients with atypical or rare seizure patterns, which can be a challenge for machine learning models. Additionally, the paper does not explore the computational efficiency or power consumption of the tensor kernel machine, which would be crucial considerations for real-world deployment, especially in low-power settings.

Further research could investigate the robustness of the method to noisy or incomplete EEG data, as well as its generalizability to other types of seizure-related physiological signals beyond EEG.

Conclusion

This paper presents an innovative approach to patient-specific seizure detection using a tensor kernel machine and transfer learning. By leveraging pre-trained models and fine-tuning them on small amounts of patient data, the method can achieve accurate seizure detection with minimal patient-specific training, making it a promising solution for practical, real-world deployment. While the paper has some limitations, it represents an important step forward in the field of personalized seizure detection and management.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🔎

Total Score

0

Efficient Patient Fine-Tuned Seizure Detection with a Tensor Kernel Machine

Seline J. S. de Rooij, Frederiek Wesel, Borb'ala Hunyadi

Recent developments in wearable devices have made accurate and efficient seizure detection more important than ever. A challenge in seizure detection is that patient-specific models typically outperform patient-independent models. However, in a wearable device one typically starts with a patient-independent model, until such patient-specific data is available. To avoid having to construct a new classifier with this data, as required in conventional kernel machines, we propose a transfer learning approach with a tensor kernel machine. This method learns the primal weights in a compressed form using the canonical polyadic decomposition, making it possible to efficiently update the weights of the patient-independent model with patient-specific data. The results show that this patient fine-tuned model reaches as high a performance as a patient-specific SVM model with a model size that is twice as small as the patient-specific model and ten times as small as the patient-independent model.

Read more

8/2/2024

Energy-Efficient Seizure Detection Suitable for low-power Applications
Total Score

0

Energy-Efficient Seizure Detection Suitable for low-power Applications

Julia Werner, Bhavya Kohli, Paul Palomero Bernardo, Christoph Gerum, Oliver Bringmann

Epilepsy is the most common, chronic, neurological disease worldwide and is typically accompanied by reoccurring seizures. Neuro implants can be used for effective treatment by suppressing an upcoming seizure upon detection. Due to the restricted size and limited battery lifetime of those medical devices, the employed approach also needs to be limited in size and have low energy requirements. We present an energy-efficient seizure detection approach involving a TC-ResNet and time-series analysis which is suitable for low-power edge devices. The presented approach allows for accurate seizure detection without preceding feature extraction while considering the stringent hardware requirements of neural implants. The approach is validated using the CHB-MIT Scalp EEG Database with a 32-bit floating point model and a hardware suitable 4-bit fixed point model. The presented method achieves an accuracy of 95.28%, a sensitivity of 92.34% and an AUC score of 0.9384 on this dataset with 4-bit fixed point representation. Furthermore, the power consumption of the model is measured with the low-power AI accelerator UltraTrail, which only requires 495 nW on average. Due to this low-power consumption this classification approach is suitable for real-time seizure detection on low-power wearable devices such as neural implants.

Read more

6/26/2024

BISeizuRe: BERT-Inspired Seizure Data Representation to Improve Epilepsy Monitoring
Total Score

0

BISeizuRe: BERT-Inspired Seizure Data Representation to Improve Epilepsy Monitoring

Luca Benfenati, Thorir Mar Ingolfsson, Andrea Cossettini, Daniele Jahier Pagliari, Alessio Burrello, Luca Benini

This study presents a novel approach for EEG-based seizure detection leveraging a BERT-based model. The model, BENDR, undergoes a two-phase training process. Initially, it is pre-trained on the extensive Temple University Hospital EEG Corpus (TUEG), a 1.5 TB dataset comprising over 10,000 subjects, to extract common EEG data patterns. Subsequently, the model is fine-tuned on the CHB-MIT Scalp EEG Database, consisting of 664 EEG recordings from 24 pediatric patients, of which 198 contain seizure events. Key contributions include optimizing fine-tuning on the CHB-MIT dataset, where the impact of model architecture, pre-processing, and post-processing techniques are thoroughly examined to enhance sensitivity and reduce false positives per hour (FP/h). We also explored custom training strategies to ascertain the most effective setup. The model undergoes a novel second pre-training phase before subject-specific fine-tuning, enhancing its generalization capabilities. The optimized model demonstrates substantial performance enhancements, achieving as low as 0.23 FP/h, 2.5$times$ lower than the baseline model, with a lower but still acceptable sensitivity rate, showcasing the effectiveness of applying a BERT-based approach on EEG-based seizure detection.

Read more

6/28/2024

Clinical translation of machine learning algorithms for seizure detection in scalp electroencephalography: systematic review
Total Score

0

Clinical translation of machine learning algorithms for seizure detection in scalp electroencephalography: systematic review

Nina Moutonnet, Steven White, Benjamin P Campbell, Saeid Sanei, Toshihisa Tanaka, Hong Ji, Danilo Mandic, Gregory Scott

Machine learning algorithms for seizure detection have shown considerable diagnostic potential, with recent reported accuracies reaching 100%. Yet, only few published algorithms have fully addressed the requirements for successful clinical translation. This is, for example, because the properties of training data may limit the generalisability of algorithms, algorithm performance may vary depending on which electroencephalogram (EEG) acquisition hardware was used, or run-time processing costs may be prohibitive to real-time clinical use cases. To address these issues in a critical manner, we systematically review machine learning algorithms for seizure detection with a focus on clinical translatability, assessed by criteria including generalisability, run-time costs, explainability, and clinically-relevant performance metrics. For non-specialists, the domain-specific knowledge necessary to contextualise model development and evaluation is provided. It is our hope that such critical evaluation of machine learning algorithms with respect to their potential real-world effectiveness can help accelerate clinical translation and identify gaps in the current seizure detection literature.

Read more

8/15/2024