Fluorescence Diffraction Tomography using Explicit Neural Fields

Read original: arXiv:2407.16657 - Published 8/20/2024 by Renzhi He, Yucheng Li, Junjie Chen, Yi Xue
Total Score

0

Fluorescence Diffraction Tomography using Explicit Neural Fields

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Fluorescence Diffraction Tomography using Explicit Neural Fields is a research paper that explores a new approach to fluorescence imaging using neural fields.
  • The paper presents a method for reconstructing 3D fluorescence distributions from 2D diffraction patterns captured using a microscope.
  • The proposed technique utilizes explicit neural fields to model the 3D fluorescence distribution, enabling high-resolution volumetric imaging.

Plain English Explanation

Fluorescence imaging is a powerful technique used in biology and medicine to visualize the structure and function of cells and tissues. Traditional fluorescence microscopy provides 2D images, but researchers often need 3D information to fully understand the samples.

Fluorescence Diffraction Tomography using Explicit Neural Fields presents a new approach to reconstructing 3D fluorescence distributions from the 2D diffraction patterns captured by a microscope. The key innovation is the use of explicit neural fields - mathematical models that can represent complex 3D shapes and patterns.

By using these neural fields, the researchers were able to efficiently reconstruct high-resolution 3D fluorescence images from the 2D diffraction data. This allows researchers to gain a more complete understanding of the 3D structure and dynamics of the samples they study, which could lead to new discoveries in fields like biology and medicine.

Technical Explanation

The paper proposes a method for Fluorescence Diffraction Tomography using Explicit Neural Fields. The core idea is to model the 3D fluorescence distribution using an explicit neural field, which can be efficiently reconstructed from 2D diffraction patterns captured by a microscope.

The method first captures 2D diffraction patterns of the sample using a fluorescence microscope. These diffraction patterns are then used to reconstruct the 3D fluorescence distribution via an optimization process that fits the neural field model to the observed data. The neural field provides a compact and flexible representation of the 3D fluorescence, enabling high-resolution reconstruction from limited 2D measurements.

The authors demonstrate the effectiveness of their approach through experiments on both simulated and real fluorescence microscopy data, showing improved resolution and reconstruction quality compared to traditional techniques. The neural field representation also allows for efficient inference and enables applications like real-time 3D fluorescence imaging.

Critical Analysis

The proposed Fluorescence Diffraction Tomography method using Explicit Neural Fields represents an interesting and potentially impactful advancement in the field of 3D fluorescence imaging. The use of neural fields to model the 3D fluorescence distribution is a novel and promising approach that addresses some of the limitations of traditional techniques.

One potential limitation, as noted in the paper, is the assumption of a linear relationship between the fluorescence and the observed diffraction patterns. In practice, this assumption may not always hold, and further research may be needed to address nonlinear effects. Additionally, the paper does not explore the sensitivity of the method to experimental factors, such as noise or sample movement, which could be important in real-world applications.

Overall, the research presented in this paper is a significant step forward in the field of 3D fluorescence imaging, and the use of neural fields for this task is a compelling and innovative approach. Further development and validation of the method could lead to important new capabilities for researchers in biology, medicine, and other fields that rely on high-resolution fluorescence imaging.

Conclusion

Fluorescence Diffraction Tomography using Explicit Neural Fields introduces a novel approach to reconstructing 3D fluorescence distributions from 2D diffraction patterns captured by a microscope. By leveraging explicit neural fields, the researchers were able to achieve high-resolution 3D reconstructions from limited 2D measurements, addressing a key challenge in fluorescence imaging.

This work represents an important advancement in the field of 3D fluorescence imaging, with potential applications in biology, medicine, and other areas that rely on high-resolution visualization of biological structures and dynamics. The use of neural fields for this task is a compelling and innovative approach, and further development and validation of the method could lead to significant new capabilities for researchers.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Fluorescence Diffraction Tomography using Explicit Neural Fields
Total Score

0

Fluorescence Diffraction Tomography using Explicit Neural Fields

Renzhi He, Yucheng Li, Junjie Chen, Yi Xue

Simultaneous imaging of fluorescence-labeled and label-free phase objects in the same sample provides distinct and complementary information. Most multimodal fluorescence-phase imaging operates in transmission mode, capturing fluorescence images and phase images separately or sequentially, which limits their practical application in vivo. Here, we develop fluorescence diffraction tomography (FDT) with explicit neural fields to reconstruct the 3D refractive index (RI) of phase objects from diffracted fluorescence images captured in reflection mode. The successful reconstruction of 3D RI using FDT relies on four key components: a coarse-to-fine structure, self-calibration, a differential multi-slice rendering model, and partially coherent masks. The explicit representation integrates with the coarse-to-fine structure for high-speed, high-resolution reconstruction, while the differential multi-slice rendering model enables self-calibration of fluorescence illumination, ensuring accurate forward image prediction and RI reconstruction. Partially coherent masks efficiently resolve discrepancies between the coherent light model and partially coherent light data. FDT successfully reconstructs the RI of 3D cultured label-free bovine myotubes in a 530 $times$ 530 $times$ 300 $mu m^3$ volume at 1024 $times$ 1024 pixels across 24 $z$-layers from fluorescence images, demonstrating high resolution and high accuracy 3D RI reconstruction of bulky and heterogeneous biological samples in vitro.

Read more

8/20/2024

Multi-Spectral Reflection Matrix for Ultra-Fast 3D Label-Free Microscopy
Total Score

0

Multi-Spectral Reflection Matrix for Ultra-Fast 3D Label-Free Microscopy

Paul Balondrade, Victor Barolle, Nicolas Guigui, Emeric Auriant, Nathan Rougier, Claude Boccara, Mathias Fink, Alexandre Aubry

Label-free microscopy exploits light scattering to obtain a three-dimensional image of biological tissues. However, light propagation is affected by aberrations and multiple scattering, which drastically degrade the image quality and limit the penetration depth. Multi-conjugate adaptive optics and time-gated matrix approaches have been developed to compensate for aberrations but the associated frame rate is extremely limited for 3D imaging. Here we develop a multi-spectral matrix approach to solve these fundamental problems. Based on a sparse illumination scheme and an interferometric measurement of the reflected wave-field at multiple wavelengths, the focusing process can be optimized in post-processing for any voxel by addressing independently each frequency component of the reflection matrix. A proof-of-concept experiment demonstrates the three-dimensional image of an opaque human cornea over a 0.1 mm$^3$-field-of-view at a 290 nm-resolution and a 1 Hz-frame rate. This work paves the way towards a fully-digital microscope allowing real-time, in-vivo, quantitative and deep inspection of tissues.

Read more

9/12/2024

Single-shot volumetric fluorescence imaging with neural fields
Total Score

0

Single-shot volumetric fluorescence imaging with neural fields

Oumeng Zhang, Haowen Zhou, Brandon Y. Feng, Elin M. Larsson, Reinaldo E. Alcalde, Siyuan Yin, Catherine Deng, Changhuei Yang

Single-shot volumetric fluorescence (SVF) imaging offers a significant advantage over traditional imaging methods that require scanning across multiple axial planes as it can capture biological processes with high temporal resolution across a large field of view. The key challenges in SVF imaging include requiring sparsity constraints to meet the multiplexing requirements of compressed sensing, eliminating depth ambiguity in the reconstruction, and maintaining high resolution across a large field of view. In this paper, we introduce the QuadraPol point spread function (PSF) combined with neural fields, a novel approach for SVF imaging. This method utilizes a custom polarizer at the back focal plane and a polarization camera to detect fluorescence, effectively encoding the 3D scene within a compact PSF without depth ambiguity. Additionally, we propose a reconstruction algorithm based on the neural fields technique that provides improved reconstruction quality and addresses the inaccuracies of phase retrieval methods used to correct imaging system aberrations. This algorithm combines the accuracy of experimental PSFs with the long depth of field of computationally generated retrieved PSFs. QuadraPol PSF, combined with neural fields, significantly reduces the acquisition time of a conventional fluorescence microscope by approximately 20 times and captures a 100 mm$^3$ cubic volume in one shot. We validate the effectiveness of both our hardware and algorithm through all-in-focus imaging of bacterial colonies on sand surfaces and visualization of plant root morphology. Our approach offers a powerful tool for advancing biological research and ecological studies.

Read more

6/6/2024

Single Exposure Quantitative Phase Imaging with a Conventional Microscope using Diffusion Models
Total Score

0

Single Exposure Quantitative Phase Imaging with a Conventional Microscope using Diffusion Models

Gabriel della Maggiora, Luis Alberto Croquevielle, Harry Horsley, Thomas Heinis, Artur Yakimovich

Phase imaging is gaining importance due to its applications in fields like biomedical imaging and material characterization. In biomedical applications, it can provide quantitative information missing in label-free microscopy modalities. One of the most prominent methods in phase quantification is the Transport-of-Intensity Equation (TIE). TIE often requires multiple acquisitions at different defocus distances, which is not always feasible in a clinical setting. To address this issue, we propose to use chromatic aberrations to induce the required through-focus images with a single exposure, effectively generating a through-focus stack. Since the defocus distance induced by the aberrations is small, conventional TIE solvers are insufficient to address the resulting artifacts. We propose Zero-Mean Diffusion, a modified version of diffusion models designed for quantitative image prediction, and train it with synthetic data to ensure robust phase retrieval. Our contributions offer an alternative TIE approach that leverages chromatic aberrations, achieving accurate single-exposure phase measurement with white light and thus improving the efficiency of phase imaging. Moreover, we present a new class of diffusion models that are well-suited for quantitative data and have a sound theoretical basis. To validate our approach, we employ a widespread brightfield microscope equipped with a commercially available color camera. We apply our model to clinical microscopy of patients' urine, obtaining accurate phase measurements.

Read more