A Fast and Computationally Inexpensive Method For Image Translation of 3D Volume Patient Data

Read original: arXiv:2408.09218 - Published 8/23/2024 by Cho Yang
Total Score

0

🖼️

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • The paper proposes a single-epoch modification (SEM) method for training CycleGAN, a popular image-to-image translation model.
  • CycleGAN was trained on the SynthRAD Grand Challenge Dataset, and the performance of the modified CycleGAN (CycleGAN-single) was compared to the standard CycleGAN trained on 200 epochs (CycleGAN-multi).
  • Both qualitative and quantitative evaluation metrics were used to assess model performance, which is unique for certain image-translation tasks like medical imaging.
  • The paper also introduces the FQGA (Fast Paired Image-to-Image Translation Quarter-Generator Adversary) model, which has 1/4 the number of parameters compared to CycleGAN but outperforms it in both qualitative and quantitative measures.
  • Applying the SEM method to FQGA further improved its performance compared to CycleGAN.

Plain English Explanation

The paper is about improving the efficiency and performance of CycleGAN, a popular machine learning model used for converting one type of image into another. The researchers trained CycleGAN on a dataset of medical images, specifically Cone Beam Computed Tomography (CBCT) and Computed Tomography (CT) scans.

Typically, CycleGAN is trained for around 200 epochs (a complete pass through the training data), but the researchers found that they could get similar performance by training it for only a single epoch using a method they call the "single-epoch modification" (SEM). This means the model can be trained much faster, which could be useful in time-sensitive medical applications.

The researchers also introduced a new model called FQGA, which has 25% fewer parameters than CycleGAN but still outperforms it in both visual quality and numerical measures of performance. Applying the SEM method to FQGA further improved its results compared to the standard CycleGAN.

The key insight here is that you don't always need to train a model for a long time to get good results. By carefully designing the model architecture and training procedure, the researchers were able to achieve high-quality image translations with significant efficiency gains. This could be applicable to other image-to-image translation tasks in machine learning, not just the medical imaging use case discussed in the paper.

Technical Explanation

The paper proposes a modification to the popular CycleGAN model for image-to-image translation tasks. CycleGAN is typically trained for around 200 epochs on the training data, but the researchers found that they could achieve similar performance by training it for only a single epoch using a method they call the "single-epoch modification" (SEM).

To evaluate the performance of the modified CycleGAN (referred to as CycleGAN-single), the researchers trained it on the SynthRAD Grand Challenge Dataset, which contains CBCT and CT scan images. They compared the results to the standard CycleGAN trained for 200 epochs (CycleGAN-multi) using both qualitative (visual inspection) and quantitative (PSNR, SSIM, MAE, MSE) evaluation metrics.

The paper also introduces a new model called FQGA (Fast Paired Image-to-Image Translation Quarter-Generator Adversary), which has 1/4 the number of parameters compared to CycleGAN's generator model. Despite its smaller size, FQGA was able to outperform CycleGAN in both qualitative and quantitative measures, even when trained for only 20 epochs.

Applying the SEM method to FQGA further improved its performance compared to the standard CycleGAN. The researchers note that these efficiency gains in terms of model size and training time could be applicable to other image-to-image translation tasks in machine learning, not just the medical imaging use case discussed in this paper.

Critical Analysis

The paper presents a novel approach to improving the efficiency of the CycleGAN model for image-to-image translation tasks, specifically in the context of medical imaging. The use of both qualitative and quantitative evaluation metrics is a strength, as it provides a more comprehensive assessment of the model's performance.

One potential limitation of the study is the use of a synthetic dataset (SynthRAD Grand Challenge Dataset) instead of real-world medical images. While this allows for more controlled experimentation, the performance of the models on actual clinical data may differ. It would be valuable to see the models evaluated on a larger and more diverse dataset of real CBCT and CT scans.

Additionally, the paper does not provide much detail on the specific architectural changes made to the FQGA model or the training hyperparameters used. This makes it difficult to fully understand the underlying reasons for the performance improvements and to replicate the results.

Future research could explore the applicability of the SEM method and the FQGA model to a wider range of image-to-image translation tasks beyond medical imaging. It would also be interesting to see how the models perform when faced with more challenging and diverse image datasets.

Overall, the paper presents a promising approach to improving the efficiency and performance of CycleGAN-based models, which could have significant implications for practical applications in medical imaging and beyond.

Conclusion

This paper introduces a novel single-epoch modification (SEM) method for training the CycleGAN model, which can achieve similar performance to the standard 200-epoch training but in a fraction of the time. The researchers also propose the FQGA model, which has 1/4 the number of parameters compared to CycleGAN but outperforms it in both qualitative and quantitative measures.

The efficiency gains demonstrated in this paper, both in terms of model size and training time, could have important implications for the deployment of image-to-image translation models in real-world applications, particularly in time-sensitive medical scenarios. The insights and techniques presented may also be applicable to a broader range of image-to-image translation tasks beyond the medical imaging use case discussed here.

Overall, this research represents an important step towards developing more efficient and practical machine learning models for complex image-to-image translation problems.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🖼️

Total Score

0

A Fast and Computationally Inexpensive Method For Image Translation of 3D Volume Patient Data

Cho Yang

CycleGAN was trained on SynthRAD Grand Challenge Dataset using the single-epoch modification (SEM) method proposed in this paper which is referred to as (CycleGAN-single) compared to the usual method of training CycleGAN on around 200 epochs (CycleGAN-multi). Model performance were evaluated qualitatively and quantitatively with quantitative performance metrics like PSNR, SSIM, MAE and MSE. The consideration of both quantitative and qualitative performance when evaluating a model is unique to certain image-to-image translation tasks like medical imaging of patient data as detailed in this paper. Also, this paper shows that good quantitative performance does not always imply good qualitative performance and the converse is also not always True (i.e. good qualitative performance does not always imply good quantitative performance). This paper also proposes a lightweight model called FQGA (Fast Paired Image-to-Image Translation Quarter-Generator Adversary) which has 1/4 the number of parameters compared to CycleGAN (when comparing their Generator Models). FQGA outperforms CycleGAN qualitatively and quantitatively even only after training on 20 epochs. Finally, using SEM method on FQGA allowed it to again outperform CycleGAN both quantitatively and qualitatively. These performance gains even with fewer model parameters and fewer epochs (which will result in time and computational savings) may also be applicable to other image-to-image translation tasks in Machine Learning apart from the Medical image-translation task discussed in this paper between Cone Beam Computed Tomography (CBCT) and Computed Tomography (CT) images.

Read more

8/23/2024

CycleGAN with Better Cycles
Total Score

0

CycleGAN with Better Cycles

Tongzhou Wang, Yihan Lin

CycleGAN provides a framework to train image-to-image translation with unpaired datasets using cycle consistency loss [4]. While results are great in many applications, the pixel level cycle consistency can potentially be problematic and causes unrealistic images in certain cases. In this project, we propose three simple modifications to cycle consistency, and show that such an approach achieves better results with fewer artifacts.

Read more

8/29/2024

S-CycleGAN: Semantic Segmentation Enhanced CT-Ultrasound Image-to-Image Translation for Robotic Ultrasonography
Total Score

0

S-CycleGAN: Semantic Segmentation Enhanced CT-Ultrasound Image-to-Image Translation for Robotic Ultrasonography

Yuhan Song, Nak Young Chong

Ultrasound imaging is pivotal in various medical diagnoses due to its non-invasive nature and safety. In clinical practice, the accuracy and precision of ultrasound image analysis are critical. Recent advancements in deep learning are showing great capacity of processing medical images. However, the data hungry nature of deep learning and the shortage of high-quality ultrasound image training data suppress the development of deep learning based ultrasound analysis methods. To address these challenges, we introduce an advanced deep learning model, dubbed S-CycleGAN, which generates high-quality synthetic ultrasound images from computed tomography (CT) data. This model incorporates semantic discriminators within a CycleGAN framework to ensure that critical anatomical details are preserved during the style transfer process. The synthetic images are utilized to enhance various aspects of our development of the robot-assisted ultrasound scanning system. The data and code will be available at https://github.com/yhsong98/ct-us-i2i-translation.

Read more

8/26/2024

Seg-CycleGAN : SAR-to-optical image translation guided by a downstream task
Total Score

0

Seg-CycleGAN : SAR-to-optical image translation guided by a downstream task

Hannuo Zhang, Huihui Li, Jiarui Lin, Yujie Zhang, Jianghua Fan, Hang Liu

Optical remote sensing and Synthetic Aperture Radar(SAR) remote sensing are crucial for earth observation, offering complementary capabilities. While optical sensors provide high-quality images, they are limited by weather and lighting conditions. In contrast, SAR sensors can operate effectively under adverse conditions. This letter proposes a GAN-based SAR-to-optical image translation method named Seg-CycleGAN, designed to enhance the accuracy of ship target translation by leveraging semantic information from a pre-trained semantic segmentation model. Our method utilizes the downstream task of ship target semantic segmentation to guide the training of image translation network, improving the quality of output Optical-styled images. The potential of foundation-model-annotated datasets in SAR-to-optical translation tasks is revealed. This work suggests broader research and applications for downstream-task-guided frameworks. The code will be available at https://github.com/NPULHH/

Read more

8/13/2024