Hardware Architecture Design of Model-Based Image Reconstruction Towards Palm-size Photoacoustic Tomography

Read original: arXiv:2408.06049 - Published 8/13/2024 by Yuwei Zheng, Zijian Gao, Yuting Shen, Jiadong Zhang, Daohuai Jiang, Fengyu Liu, Feng Gao, Fei Gao
Total Score

0

🖼️

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Photoacoustic (PA) imaging combines optical and ultrasound imaging to create biomedical applications.
  • Advanced image reconstruction algorithms are needed for fast, high-quality, low-cost, and portable PA imaging systems.
  • Existing iterative PA image reconstructions are computationally expensive, limiting their practical use.

Plain English Explanation

Photoacoustic imaging is a powerful medical imaging technique that combines the strengths of optical and ultrasound imaging. It has great potential for many biomedical applications. However, to make this technology widely usable, researchers need to develop fast, high-quality, low-cost, and portable imaging systems.

The key challenge is translating advanced image reconstruction algorithms, which are essential for producing accurate images, into hardware implementations. Existing iterative PA image reconstruction methods, although more accurate than simpler algorithms, require a lot of computational power, making them impractical for real-world use.

This paper introduces a new hardware acceleration architecture based on "superposed Wave" (s-Wave) to address this challenge for a palm-sized PA tomography (palm-PAT) system. The goal is to significantly improve the speed and performance of image reconstruction while keeping the system cost much lower.

Technical Explanation

The researchers propose an innovative data reuse method that dramatically reduces the hardware storage resource consumption required for the model-based image reconstruction algorithm. They implemented this algorithm on a field-programmable gate array (FPGA) and tested it using both phantom and in vivo human finger data.

The results show that the hardware-accelerated implementation of the model-based algorithm can achieve a speedup of up to approximately 270 times compared to a CPU-based implementation. Additionally, the energy efficiency ratio is improved by more than 2700 times.

This demonstrates that the proposed architecture can substantially reduce system cost while maintaining high imaging performance, making it a promising approach for developing practical, high-performance PA imaging systems.

Critical Analysis

The paper presents a novel and promising solution to a key challenge in making photoacoustic imaging more widely usable. By significantly accelerating the computationally intensive image reconstruction process in hardware, the researchers have made important progress towards enabling fast, high-quality, low-cost, and portable PA imaging systems.

However, the paper does not discuss any limitations or potential issues with the proposed approach. For example, it is unclear how the hardware-accelerated system would perform with more complex or larger-scale imaging tasks, or how it would compare to other hardware acceleration techniques. Further research and testing would be needed to fully understand the capabilities and limitations of this method.

Additionally, the paper does not mention any potential ethical considerations or social implications of the technology, such as how it could impact healthcare accessibility or patient privacy. As photoacoustic imaging becomes more advanced and widespread, it will be important for researchers to consider these broader societal impacts.

Overall, the technical work presented in this paper is impressive, but a more comprehensive critical analysis would help readers better understand the strengths, weaknesses, and broader implications of the proposed approach.

Conclusion

This paper introduces a innovative hardware acceleration architecture for model-based photoacoustic image reconstruction that significantly improves the speed and performance of the process while reducing system cost. By implementing an advanced image reconstruction algorithm in hardware using a novel data reuse method, the researchers have demonstrated a promising path towards making high-quality, portable photoacoustic imaging systems more practical and accessible for a wide range of biomedical applications.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🖼️

Total Score

0

Hardware Architecture Design of Model-Based Image Reconstruction Towards Palm-size Photoacoustic Tomography

Yuwei Zheng, Zijian Gao, Yuting Shen, Jiadong Zhang, Daohuai Jiang, Fengyu Liu, Feng Gao, Fei Gao

Photoacoustic (PA) imaging technology combines the advantages of optical imaging and ultrasound imaging, showing great potential in biomedical applications. Many preclinical studies and clinical applications urgently require fast, high-quality, low-cost and portable imaging system. Translating advanced image reconstruction algorithms into hardware implementations is highly desired. However, existing iterative PA image reconstructions, although exhibit higher accuracy than delay-and-sum algorithm, suffer from high computational cost. In this paper, we introduce a model-based hardware acceleration architecture based on superposed Wave (s-Wave) for palm-size PA tomography (palm-PAT), aiming at enhancing both the speed and performance of image reconstruction at a much lower system cost. To achieve this, we propose an innovative data reuse method that significantly reduces hardware storage resource consumption. We conducted experiments by FPGA implementation of the algorithm, using both phantoms and in vivo human finger data to verify the feasibility of the proposed method. The results demonstrate that our proposed architecture can substantially reduce system cost while maintaining high imaging performance. The hardware-accelerated implementation of the model-based algorithm achieves a speedup of up to approximately 270 times compared to the CPU, while the corresponding energy efficiency ratio is improved by more than 2700 times.

Read more

8/13/2024

🖼️

Total Score

0

Streamlined Photoacoustic Image Processing with Foundation Models: A Training-Free Solution

Handi Deng, Yucheng Zhou, Jiaxuan Xiang, Liujie Gu, Yan Luo, Hai Feng, Mingyuan Liu, Cheng Ma

Foundation models have rapidly evolved and have achieved significant accomplishments in computer vision tasks. Specifically, the prompt mechanism conveniently allows users to integrate image prior information into the model, making it possible to apply models without any training. Therefore, we propose a method based on foundation models and zero training to solve the tasks of photoacoustic (PA) image segmentation. We employed the segment anything model (SAM) by setting simple prompts and integrating the model's outputs with prior knowledge of the imaged objects to accomplish various tasks, including: (1) removing the skin signal in three-dimensional PA image rendering; (2) dual speed-of-sound reconstruction, and (3) segmentation of finger blood vessels. Through these demonstrations, we have concluded that deep learning can be directly applied in PA imaging without the requirement for network design and training. This potentially allows for a hands-on, convenient approach to achieving efficient and accurate segmentation of PA images. This letter serves as a comprehensive tutorial, facilitating the mastery of the technique through the provision of code and sample datasets.

Read more

4/12/2024

Sparse-view Signal-domain Photoacoustic Tomography Reconstruction Method Based on Neural Representation
Total Score

0

Sparse-view Signal-domain Photoacoustic Tomography Reconstruction Method Based on Neural Representation

Bowei Yao, Yi Zeng, Haizhao Dai, Qing Wu, Youshen Xiao, Fei Gao, Yuyao Zhang, Jingyi Yu, Xiran Cai

Photoacoustic tomography is a hybrid biomedical technology, which combines the advantages of acoustic and optical imaging. However, for the conventional image reconstruction method, the image quality is affected obviously by artifacts under the condition of sparse sampling. in this paper, a novel model-based sparse reconstruction method via implicit neural representation was proposed for improving the image quality reconstructed from sparse data. Specially, the initial acoustic pressure distribution was modeled as a continuous function of spatial coordinates, and parameterized by a multi-layer perceptron. The weights of multi-layer perceptron were determined by training the network in self-supervised manner. And the total variation regularization term was used to offer the prior knowledge. We compared our result with some ablation studies, and the results show that out method outperforms existing methods on simulation and experimental data. Under the sparse sampling condition, our method can suppress the artifacts and avoid the ill-posed problem effectively, which reconstruct images with higher signal-to-noise ratio and contrast-to-noise ratio than traditional methods. The high-quality results for sparse data make the proposed method hold the potential for further decreasing the hardware cost of photoacoustic tomography system.

Read more

6/26/2024

HDN:Hybrid Deep-learning and Non-line-of-sight Reconstruction Framework for Photoacoustic Brain Imaging
Total Score

0

HDN:Hybrid Deep-learning and Non-line-of-sight Reconstruction Framework for Photoacoustic Brain Imaging

Pengcheng Wan, Fan Zhang, Yuting Shen, Xin Shang, Hulin Zhao, Shuangli Liu, Xiaohua Feng, Fei Gao

Photoacoustic imaging (PAI) combines the high contrast of optical imaging with the deep penetration depth of ultrasonic imaging, showing great potential in cerebrovascular disease detection. However, the ultrasonic wave suffers strong attenuation and multi-scattering when it passes through the skull tissue, resulting in the distortion of the collected photoacoustic (PA) signal. In this paper, inspired by the principles of deep learning and non-line-of-sight (NLOS) imaging, we propose an image reconstruction framework named HDN (Hybrid Deep-learning and Non-line-of-sight), which consists of the signal extraction part and difference utilization part. The signal extraction part is used to correct the distorted signal and reconstruct an initial image. The difference utilization part is used to make further use of the signal difference between the distorted signal and corrected signal, reconstructing the residual image between the initial image and the target image. The test results on a PA digital brain simulation dataset show that compared with the traditional delay-and-sum (DAS) method and deep-learning-based method, HDN achieved superior performance in both signal correction and image reconstruction. Specifically for the SSIM index, the HDN reached 0.606 in imaging results, compared to 0.154 for the DAS method and 0.307 for the deep-learning-based method.

Read more