Low-rank based motion correction followed by automatic frame selection in DT-CMR

Read original: arXiv:2406.13708 - Published 6/21/2024 by Fanwen Wang, Pedro F. Ferreira, Camila Munoz, Ke Wen, Yaqing Luo, Jiahao Huang, Yinzhe Wu, Dudley J. Pennell, Andrew D. Scott, Sonia Nielles-Vallespin and 1 other
Total Score

0

🖼️

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Diffusion tensor cardiac magnetic resonance (DT-CMR) imaging is challenging due to low signal-to-noise ratio (SNR) and variation in contrast between frames, making image registration difficult and requiring manual rejection of motion-corrupted frames.
  • The study aimed to develop a semi-automatic post-processing pipeline for robust DT-CMR registration and automatic frame selection.
  • The proposed method used low intrinsic rank averaged frames as the reference to register other low-ranked frames and a myocardium-guided frame selection to reject frames with signal loss, through-plane motion, and poor registration.

Plain English Explanation

Diffusion tensor cardiac magnetic resonance (DT-CMR) imaging is a powerful tool for studying the structure and function of the heart. However, this technique has some challenges. The images often have a low signal-to-noise ratio, meaning the useful information is buried in a lot of background noise. Additionally, the contrast between different frames, or images, can vary a lot, which makes it hard to align, or "register," the frames with each other.

To address these issues, the researchers developed a semi-automatic post-processing pipeline. This means the process is mostly automated, but still requires some human intervention. The key steps are:

  1. Using the low-noise, averaged frames as a reference to align the other frames. This helps overcome the registration challenges caused by the variable contrast between frames.
  2. Automatically rejecting frames that are corrupted by motion, have signal loss, or are poorly registered. This ensures the final analysis is based on high-quality data.

By using this semi-automatic approach, the researchers were able to improve the quality of the helix angle data (a measure of heart muscle structure) and reduce the number of negative eigenvalues (a sign of poor data quality) in healthy volunteers. This suggests the method could be a valuable tool for researchers and clinicians studying the heart using DT-CMR imaging.

Technical Explanation

The researchers used a low intrinsic rank averaged frames as the reference to register other low-ranked frames. This helped overcome the challenges posed by the low signal-to-noise ratio (SNR) and variable contrast between frames, which can make image registration difficult.

The team also developed a myocardium-guided frame selection algorithm to automatically reject frames that were corrupted by signal loss, through-plane motion, or poor registration. This ensured the final analysis was based on high-quality data.

Compared to their previous noise-robust rigid registration approach, the new method showed improvements in the quality of the helix angle data and reduced the number of negative eigenvalues in healthy volunteers.

Critical Analysis

The paper provides a promising semi-automatic solution to address the challenges in post-processing DT-CMR data. However, the researchers acknowledge that the method has only been evaluated on healthy volunteers, and further testing is needed to assess its performance on patient data with more severe motion artifacts or other pathologies.

Additionally, while the automatic frame selection algorithm helps reduce the burden of manual data curation, it may still reject some frames that could contain valuable information. An [advanced PCA-RELAX approach could potentially be explored to retain more of the original data while still providing robust registration.

Overall, the research represents a valuable step forward in improving the quality and reliability of DT-CMR analysis, but there is still room for further refinement and validation to make the technique more widely applicable in clinical and research settings.

Conclusion

This study presents a semi-automatic post-processing pipeline that addresses key challenges in diffusion tensor cardiac magnetic resonance (DT-CMR) imaging. By using low-rank averaged frames as a registration reference and an automated frame selection algorithm, the researchers were able to improve the quality of the helix angle data and reduce negative eigenvalues in healthy volunteers.

While further testing on patient data is needed, this work represents an important advancement in making DT-CMR a more robust and reliable tool for studying the structure and function of the heart. As DT-CMR imaging becomes more widely adopted, techniques like this will be crucial for extracting meaningful insights from the data and supporting advances in cardiac research and clinical care.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🖼️

Total Score

0

Low-rank based motion correction followed by automatic frame selection in DT-CMR

Fanwen Wang, Pedro F. Ferreira, Camila Munoz, Ke Wen, Yaqing Luo, Jiahao Huang, Yinzhe Wu, Dudley J. Pennell, Andrew D. Scott, Sonia Nielles-Vallespin, Guang Yang

Motivation: Post-processing of in-vivo diffusion tensor CMR (DT-CMR) is challenging due to the low SNR and variation in contrast between frames which makes image registration difficult, and the need to manually reject frames corrupted by motion. Goals: To develop a semi-automatic post-processing pipeline for robust DT-CMR registration and automatic frame selection. Approach: We used low intrinsic rank averaged frames as the reference to register other low-ranked frames. A myocardium-guided frame selection rejected the frames with signal loss, through-plane motion and poor registration. Results: The proposed method outperformed our previous noise-robust rigid registration on helix angle data quality and reduced negative eigenvalues in healthy volunteers.

Read more

6/21/2024

🧠

Total Score

0

Efficient Post-processing of Diffusion Tensor Cardiac Magnetic Imaging Using Texture-conserving Deformable Registration

Fanwen Wang, Pedro F. Ferreira, Yinzhe Wu, Camila Munoz, Ke Wen, Yaqing Luo, Jiahao Huang, Dudley J. Pennell, Andrew D. Scott, Sonia Nielles-Vallespin, Guang Yang

Diffusion tensor cardiac magnetic resonance (DT-CMR) is a method capable of providing non-invasive measurements of myocardial microstructure. Image registration is essential to correct image shifts due to intra and inter breath-hold motion and imperfect cardiac triggering. Registration is challenging in DT-CMR due to the low signal-to-noise and various contrasts induced by the diffusion encoding in the myocardium and surrounding organs. Traditional deformable registration corrects through-plane motion but at the risk of destroying the texture information while rigid registration inefficiently discards frames with local deformation. In this study, we explored the possibility of deep learning-based deformable registration on DT-CMR. Based on the noise suppression using low-rank features and diffusion encoding suppression using variational auto encoder-decoder, a B-spline based registration network extracted the displacement fields and maintained the texture features of DT-CMR. In this way, our method improved the efficiency of frame utilization, manual cropping, and computational speed.

Read more

5/17/2024

🔄

Total Score

0

Motion-compensated MR CINE reconstruction with reconstruction-driven motion estimation

Jiazhen Pan, Wenqi Huang, Daniel Rueckert, Thomas Kustner, Kerstin Hammernik

In cardiac CINE, motion-compensated MR reconstruction (MCMR) is an effective approach to address highly undersampled acquisitions by incorporating motion information between frames. In this work, we propose a novel perspective for addressing the MCMR problem and a more integrated and efficient solution to the MCMR field. Contrary to state-of-the-art (SOTA) MCMR methods which break the original problem into two sub-optimization problems, i.e. motion estimation and reconstruction, we formulate this problem as a single entity with one single optimization. Our approach is unique in that the motion estimation is directly driven by the ultimate goal, reconstruction, but not by the canonical motion-warping loss (similarity measurement between motion-warped images and target images). We align the objectives of motion estimation and reconstruction, eliminating the drawbacks of artifacts-affected motion estimation and therefore error-propagated reconstruction. Further, we can deliver high-quality reconstruction and realistic motion without applying any regularization/smoothness loss terms, circumventing the non-trivial weighting factor tuning. We evaluate our method on two datasets: 1) an in-house acquired 2D CINE dataset for the retrospective study and 2) the public OCMR cardiac dataset for the prospective study. The conducted experiments indicate that the proposed MCMR framework can deliver artifact-free motion estimation and high-quality MR images even for imaging accelerations up to 20x, outperforming SOTA non-MCMR and MCMR methods in both qualitative and quantitative evaluation across all experiments. The code is available at https://github.com/JZPeterPan/MCMR-Recon-Driven-Motion.

Read more

8/19/2024

Attention-aware non-rigid image registration for accelerated MR imaging
Total Score

0

Attention-aware non-rigid image registration for accelerated MR imaging

Aya Ghoul, Jiazhen Pan, Andreas Lingg, Jens Kubler, Patrick Krumm, Kerstin Hammernik, Daniel Rueckert, Sergios Gatidis, Thomas Kustner

Accurate motion estimation at high acceleration factors enables rapid motion-compensated reconstruction in Magnetic Resonance Imaging (MRI) without compromising the diagnostic image quality. In this work, we introduce an attention-aware deep learning-based framework that can perform non-rigid pairwise registration for fully sampled and accelerated MRI. We extract local visual representations to build similarity maps between the registered image pairs at multiple resolution levels and additionally leverage long-range contextual information using a transformer-based module to alleviate ambiguities in the presence of artifacts caused by undersampling. We combine local and global dependencies to perform simultaneous coarse and fine motion estimation. The proposed method was evaluated on in-house acquired fully sampled and accelerated data of 101 patients and 62 healthy subjects undergoing cardiac and thoracic MRI. The impact of motion estimation accuracy on the downstream task of motion-compensated reconstruction was analyzed. We demonstrate that our model derives reliable and consistent motion fields across different sampling trajectories (Cartesian and radial) and acceleration factors of up to 16x for cardiac motion and 30x for respiratory motion and achieves superior image quality in motion-compensated reconstruction qualitatively and quantitatively compared to conventional and recent deep learning-based approaches. The code is publicly available at https://github.com/lab-midas/GMARAFT.

Read more

4/30/2024