MRI Recovery with Self-Calibrated Denoisers without Fully-Sampled Data

2304.12890

YC

0

Reddit

0

Published 6/3/2024 by Sizhuo Liu, Muhammad Shafique, Philip Schniter, Rizwan Ahmad

📊

Abstract

Objective: Acquiring fully sampled training data is challenging for many MRI applications. We present a self-supervised image reconstruction method, termed ReSiDe, capable of recovering images solely from undersampled data. Materials and Methods: ReSiDe is inspired by plug-and-play (PnP) methods, but unlike traditional PnP approaches that utilize pre-trained denoisers, ReSiDe iteratively trains the denoiser on the image or images that are being reconstructed. We introduce two variations of our method: ReSiDe-S and ReSiDe-M. ReSiDe-S is scan-specific and works with a single set of undersampled measurements, while ReSiDe-M operates on multiple sets of undersampled measurements and provides faster inference. Studies I, II, and III compare ReSiDe-S and ReSiDe-M against other self-supervised or unsupervised methods using data from T1- and T2-weighted brain MRI, MRXCAT digital perfusion phantom, and first-pass cardiac perfusion, respectively. Results: ReSiDe-S and ReSiDe-M outperform other methods in terms of reconstruction signal-to-noise ratio and structural similarity index measure for Studies I and II, and in terms of expert scoring for Study III. Discussion: We present a self-supervised image reconstruction method and validate it in both static and dynamic MRI applications. These developments can benefit MRI applications where the availability of fully sampled training data is limited.

Create account to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents a self-supervised image reconstruction method called ReSiDe, which can recover images from undersampled MRI data without the need for fully sampled training data.
  • ReSiDe is inspired by plug-and-play (PnP) methods, but instead of using pre-trained denoisers, it iteratively trains the denoiser on the images being reconstructed.
  • The authors introduce two variations of ReSiDe: ReSiDe-S, which works with a single set of undersampled measurements, and ReSiDe-M, which operates on multiple sets of undersampled measurements and provides faster inference.
  • The method is evaluated on T1- and T2-weighted brain MRI, a digital perfusion phantom, and first-pass cardiac perfusion data, and is shown to outperform other self-supervised or unsupervised methods.

Plain English Explanation

MRI (Magnetic Resonance Imaging) is a widely used medical imaging technique, but acquiring fully sampled training data for MRI applications can be challenging. The researchers in this paper have developed a new method called ReSiDe that can recover high-quality MRI images from undersampled data, without needing access to fully sampled training data.

The key idea behind ReSiDe is that it "trains itself" to reconstruct the images. Rather than using a pre-trained model, ReSiDe iteratively trains a denoiser (a type of machine learning model) on the undersampled data it is trying to reconstruct. This allows it to adapt to the specific characteristics of the data, rather than relying on a one-size-fits-all approach.

The researchers developed two versions of ReSiDe: ReSiDe-S and ReSiDe-M. ReSiDe-S works with a single set of undersampled measurements, while ReSiDe-M can use multiple sets of undersampled data, which allows it to reconstruct the images faster.

The researchers tested ReSiDe on several different MRI datasets, including brain MRI, a digital perfusion phantom, and cardiac perfusion data. In all cases, ReSiDe outperformed other self-supervised or unsupervised methods, demonstrating its effectiveness at recovering high-quality images from limited data.

This research is important because it could help overcome the challenge of limited training data in many MRI applications, enabling better image reconstruction and potentially improving patient care.

Technical Explanation

The paper presents a self-supervised image reconstruction method called ReSiDe, which is designed to recover high-quality images from undersampled MRI data without the need for fully sampled training data.

ReSiDe is inspired by plug-and-play (PnP) methods, but instead of using pre-trained denoisers, it iteratively trains the denoiser on the image(s) being reconstructed. The authors introduce two variations of the method:

  1. ReSiDe-S: A scan-specific version that works with a single set of undersampled measurements.
  2. ReSiDe-M: A multi-scan version that operates on multiple sets of undersampled measurements, which provides faster inference.

The authors evaluate ReSiDe-S and ReSiDe-M on three different studies:

  1. Study I: T1- and T2-weighted brain MRI data.
  2. Study II: MRXCAT digital perfusion phantom data.
  3. Study III: First-pass cardiac perfusion data.

In all three studies, ReSiDe-S and ReSiDe-M outperform other self-supervised or unsupervised methods in terms of reconstruction signal-to-noise ratio (SNR) and structural similarity index measure (SSIM) for Studies I and II, and in terms of expert scoring for Study III.

The key technical innovation of ReSiDe is its ability to "train itself" on the undersampled data it is trying to reconstruct, rather than relying on a pre-trained model. This allows the method to adapt to the specific characteristics of the data, which can vary across different MRI applications.

The multi-scan version, ReSiDe-M, further improves the method's performance by leveraging multiple sets of undersampled data, which enables faster inference without sacrificing reconstruction quality.

Critical Analysis

The paper presents a compelling approach to MRI image reconstruction that addresses the challenge of limited training data, a common issue in many MRI applications. The authors have demonstrated the effectiveness of ReSiDe across several different MRI datasets, which is a strength of the research.

However, the paper does not discuss the computational complexity or runtime of the ReSiDe method, which would be an important consideration for real-world deployment. Additionally, the paper does not provide much insight into the limitations or failure cases of the method, which would be helpful for understanding its broader applicability and potential issues.

It would also be interesting to see how ReSiDe compares to other self-supervised or unsupervised MRI reconstruction techniques beyond the ones evaluated in the paper. This could help provide a more comprehensive understanding of the method's strengths and weaknesses relative to the state of the art.

Overall, the paper presents a promising self-supervised approach to MRI reconstruction that could have significant implications for the field. Further research to address the computational and performance considerations would help solidify the method's practical feasibility and potential impact.

Conclusion

This paper introduces a self-supervised image reconstruction method called ReSiDe that can recover high-quality MRI images from undersampled data, without the need for fully sampled training data. The key innovation of ReSiDe is its ability to "train itself" on the undersampled data it is trying to reconstruct, allowing the method to adapt to the specific characteristics of the data.

The authors have demonstrated the effectiveness of ReSiDe across several different MRI applications, including brain MRI, digital perfusion phantom, and cardiac perfusion data. The method outperforms other self-supervised and unsupervised techniques, highlighting its potential to address the challenge of limited training data in many MRI applications.

This research could have significant implications for the field of MRI, enabling better image reconstruction and potentially improving patient care in a wide range of medical imaging scenarios. Further research to address the computational and performance considerations of the method would help solidify its practical feasibility and broader impact.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Related Papers

🎯

CL-MRI: Self-Supervised Contrastive Learning to Improve the Accuracy of Undersampled MRI Reconstruction

Mevan Ekanayake, Zhifeng Chen, Mehrtash Harandi, Gary Egan, Zhaolin Chen

YC

0

Reddit

0

In Magnetic Resonance Imaging (MRI), image acquisitions are often undersampled in the measurement domain to accelerate the scanning process, at the expense of image quality. However, image quality is a crucial factor that influences the accuracy of clinical diagnosis; hence, high-quality image reconstruction from undersampled measurements has been a key area of research. Recently, deep learning (DL) methods have emerged as the state-of-the-art for MRI reconstruction, typically involving deep neural networks to transform undersampled MRI images into high-quality MRI images through data-driven processes. Nevertheless, there is clear and significant room for improvement in undersampled DL MRI reconstruction to meet the high standards required for clinical diagnosis, in terms of eliminating aliasing artifacts and reducing image noise. In this paper, we introduce a self-supervised pretraining procedure using contrastive learning to improve the accuracy of undersampled DL MRI reconstruction. We use contrastive learning to transform the MRI image representations into a latent space that maximizes mutual information among different undersampled representations and optimizes the information content at the input of the downstream DL reconstruction models. Our experiments demonstrate improved reconstruction accuracy across a range of acceleration factors and datasets, both quantitatively and qualitatively. Furthermore, our extended experiments validate the proposed framework's robustness under adversarial conditions, such as measurement noise, different k-space sampling patterns, and pathological abnormalities, and also prove the transfer learning capabilities on MRI datasets with completely different anatomy. Additionally, we conducted experiments to visualize and analyze the properties of the proposed MRI contrastive learning latent space.

Read more

5/31/2024

🔗

Fast Controllable Diffusion Models for Undersampled MRI Reconstruction

Wei Jiang, Zhuang Xiong, Feng Liu, Nan Ye, Hongfu Sun

YC

0

Reddit

0

Supervised deep learning methods have shown promise in undersampled Magnetic Resonance Imaging (MRI) reconstruction, but their requirement for paired data limits their generalizability to the diverse MRI acquisition parameters. Recently, unsupervised controllable generative diffusion models have been applied to undersampled MRI reconstruction, without paired data or model retraining for different MRI acquisitions. However, diffusion models are generally slow in sampling and state-of-the-art acceleration techniques can lead to sub-optimal results when directly applied to the controllable generation process. This study introduces a new algorithm called Predictor-Projector-Noisor (PPN), which enhances and accelerates controllable generation of diffusion models for undersampled MRI reconstruction. Our results demonstrate that PPN produces high-fidelity MR images that conform to undersampled k-space measurements with significantly shorter reconstruction time than other controllable sampling methods. In addition, the unsupervised PPN accelerated diffusion models are adaptable to different MRI acquisition parameters, making them more practical for clinical use than supervised learning techniques.

Read more

6/12/2024

Self-Supervised MRI Reconstruction with Unrolled Diffusion Models

Self-Supervised MRI Reconstruction with Unrolled Diffusion Models

Yilmaz Korkmaz, Tolga Cukur, Vishal M. Patel

YC

0

Reddit

0

Magnetic Resonance Imaging (MRI) produces excellent soft tissue contrast, albeit it is an inherently slow imaging modality. Promising deep learning methods have recently been proposed to reconstruct accelerated MRI scans. However, existing methods still suffer from various limitations regarding image fidelity, contextual sensitivity, and reliance on fully-sampled acquisitions for model training. To comprehensively address these limitations, we propose a novel self-supervised deep reconstruction model, named Self-Supervised Diffusion Reconstruction (SSDiffRecon). SSDiffRecon expresses a conditional diffusion process as an unrolled architecture that interleaves cross-attention transformers for reverse diffusion steps with data-consistency blocks for physics-driven processing. Unlike recent diffusion methods for MRI reconstruction, a self-supervision strategy is adopted to train SSDiffRecon using only undersampled k-space data. Comprehensive experiments on public brain MR datasets demonstrates the superiority of SSDiffRecon against state-of-the-art supervised, and self-supervised baselines in terms of reconstruction speed and quality. Implementation will be available at https://github.com/yilmazkorkmaz1/SSDiffRecon.

Read more

4/17/2024

The MRI Scanner as a Diagnostic: Image-less Active Sampling

The MRI Scanner as a Diagnostic: Image-less Active Sampling

Yuning Du, Rohan Dharmakumar, Sotirios A. Tsaftaris

YC

0

Reddit

0

Despite the high diagnostic accuracy of Magnetic Resonance Imaging (MRI), using MRI as a Point-of-Care (POC) disease identification tool poses significant accessibility challenges due to the use of high magnetic field strength and lengthy acquisition times. We ask a simple question: Can we dynamically optimise acquired samples, at the patient level, according to an (automated) downstream decision task, while discounting image reconstruction? We propose an ML-based framework that learns an active sampling strategy, via reinforcement learning, at a patient-level to directly infer disease from undersampled k-space. We validate our approach by inferring Meniscus Tear in undersampled knee MRI data, where we achieve diagnostic performance comparable with ML-based diagnosis, using fully sampled k-space data. We analyse task-specific sampling policies, showcasing the adaptability of our active sampling approach. The introduced frugal sampling strategies have the potential to reduce high field strength requirements that in turn strengthen the viability of MRI-based POC disease identification and associated preliminary screening tools.

Read more

6/26/2024