Multi-graph Graph Matching for Coronary Artery Semantic Labeling

Read original: arXiv:2402.15894 - Published 8/16/2024 by Chen Zhao, Zhihui Xu, Pukar Baral, Michel Esposito, Weihua Zhou
Total Score

0

Multi-graph Graph Matching for Coronary Artery Semantic Labeling

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • The paper presents a method for semantic labeling of coronary artery structures in invasive coronary angiography (ICA) images using a multi-graph graph matching approach.
  • The goal is to automatically identify and label key anatomical structures in ICA images, which can assist clinicians in diagnosis and treatment planning for coronary artery disease.
  • The proposed method leverages deep learning techniques to extract informative features from the ICA images and uses a graph matching algorithm to associate these features with pre-defined semantic labels.

Plain English Explanation

The paper describes a new way to automatically identify and label important structures in medical images of the heart's coronary arteries. These images, called invasive coronary angiograms, are commonly used by doctors to diagnose and treat coronary artery disease.

The researchers developed a deep learning approach that can automatically recognize key anatomical features in the angiogram images, such as the different coronary arteries and their branches. This is done by first extracting informative visual features from the images using deep neural networks.

Next, the method uses a graph matching algorithm to associate these extracted features with pre-defined semantic labels that describe the corresponding anatomical structures. This allows the system to automatically label the different coronary arteries and their locations in the images.

The key innovation is the use of a "multi-graph" approach, which takes into account the complex relationship between the different coronary artery segments and their spatial arrangement. This helps improve the accuracy and robustness of the semantic labeling.

Overall, this automated labeling system could be a valuable tool to assist clinicians in quickly and accurately interpreting coronary angiogram images, leading to better diagnosis and treatment of coronary artery disease.

Technical Explanation

The paper proposes a multi-graph graph matching approach for semantic labeling of coronary artery structures in invasive coronary angiography (ICA) images.

The method first uses a deep convolutional neural network to extract visual features from the ICA images. These features are then used to construct multiple graphs, each representing a different level of granularity in the coronary artery anatomy.

A graph matching algorithm is then applied to associate the extracted visual features with pre-defined semantic labels that correspond to anatomical structures like the left main, left anterior descending, and right coronary arteries. The multi-graph representation allows the algorithm to capture the complex spatial and hierarchical relationships between these different coronary artery segments.

The key technical contributions include:

  1. A multi-graph representation that encodes the hierarchical and spatial structure of the coronary arteries
  2. A graph matching algorithm that can efficiently solve the semantic labeling problem using the multi-graph inputs
  3. A deep learning-based feature extraction module that provides informative visual cues for the graph matching

Experiments on a large dataset of ICA images demonstrate the effectiveness of the proposed method, with significant improvements in semantic labeling accuracy compared to baseline approaches.

Critical Analysis

The paper presents a well-designed and technically sound approach for automating the semantic labeling of coronary artery structures in ICA images. The use of a multi-graph representation to capture the complex anatomy is a key strength, as it allows the model to better reason about the spatial relationships between different artery segments.

However, the paper does not discuss the potential limitations or challenges in applying this method in real-world clinical settings. For example, the performance of the system may degrade on low-quality or atypical ICA images that differ from the training data. Additionally, the paper does not explore the robustness of the method to variations in imaging protocols or patient characteristics.

Further research could also investigate ways to make the system more interpretable, so that clinicians can understand the reasoning behind the semantic labels generated by the model. This could help build trust and facilitate the adoption of such automated tools in medical practice.

Conclusion

This paper presents a novel multi-graph graph matching approach for the semantic labeling of coronary artery structures in invasive coronary angiography (ICA) images. The method leverages deep learning and graph-based techniques to accurately identify and label key anatomical features, which could be a valuable tool to assist clinicians in the diagnosis and treatment of coronary artery disease.

While the technical approach is well-designed, further research is needed to address potential real-world challenges and improve the interpretability of the system. Overall, this work represents an important step towards the development of automated image analysis tools for cardiovascular imaging applications.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Multi-graph Graph Matching for Coronary Artery Semantic Labeling
Total Score

0

Multi-graph Graph Matching for Coronary Artery Semantic Labeling

Chen Zhao, Zhihui Xu, Pukar Baral, Michel Esposito, Weihua Zhou

Coronary artery disease (CAD) stands as the leading cause of death worldwide, and invasive coronary angiography (ICA) remains the gold standard for assessing vascular anatomical information. However, deep learning-based methods encounter challenges in generating semantic labels for arterial segments, primarily due to the morphological similarity between arterial branches and varying anatomy of arterial system between different projection view angles and patients. To address this challenge, we model the vascular tree as a graph and propose a multi-graph graph matching (MGM) algorithm for coronary artery semantic labeling. The MGM algorithm assesses the similarity between arterials in multiple vascular tree graphs, considering the cycle consistency between each pair of graphs. As a result, the unannotated arterial segments are appropriately labeled by matching them with annotated segments. Through the incorporation of anatomical graph structure, radiomics features, and semantic mapping, the proposed MGM model achieves an impressive accuracy of 0.9471 for coronary artery semantic labeling using our multi-site dataset with 718 ICAs. With the semantic labeled arteries, an overall accuracy of 0.9155 was achieved for stenosis detection. The proposed MGM presents a novel tool for coronary artery analysis using multiple ICA-derived graphs, offering valuable insights into vascular health and pathology.

Read more

8/16/2024

Deep Learning-based 3D Coronary Tree Reconstruction from Two 2D Non-simultaneous X-ray Angiography Projections
Total Score

0

Deep Learning-based 3D Coronary Tree Reconstruction from Two 2D Non-simultaneous X-ray Angiography Projections

Yiying Wang, Abhirup Banerjee, Robin P. Choudhury, Vicente Grau

Cardiovascular diseases (CVDs) are the most common cause of death worldwide. Invasive x-ray coronary angiography (ICA) is one of the most important imaging modalities for the diagnosis of CVDs. ICA typically acquires only two 2D projections, which makes the 3D geometry of coronary vessels difficult to interpret, thus requiring 3D coronary tree reconstruction from two projections. State-of-the-art approaches require significant manual interactions and cannot correct the non-rigid cardiac and respiratory motions between non-simultaneous projections. In this study, we propose a novel deep learning pipeline. We leverage the Wasserstein conditional generative adversarial network with gradient penalty, latent convolutional transformer layers, and a dynamic snake convolutional critic to implicitly compensate for the non-rigid motion and provide 3D coronary tree reconstruction. Through simulating projections from coronary computed tomography angiography (CCTA), we achieve the generalisation of 3D coronary tree reconstruction on real non-simultaneous ICA projections. We incorporate an application-specific evaluation metric to validate our proposed model on both a CCTA dataset and a real ICA dataset, together with Chamfer L1 distance. The results demonstrate the good performance of our model in vessel topology preservation, recovery of missing features, and generalisation ability to real ICA data. To the best of our knowledge, this is the first study that leverages deep learning to achieve 3D coronary tree reconstruction from two real non-simultaneous x-ray angiography projections.

Read more

7/23/2024

NeCA: 3D Coronary Artery Tree Reconstruction from Two 2D Projections by Neural Implicit Representation
Total Score

0

NeCA: 3D Coronary Artery Tree Reconstruction from Two 2D Projections by Neural Implicit Representation

Yiying Wang, Abhirup Banerjee, Vicente Grau

Cardiovascular diseases (CVDs) are the most common health threats worldwide. 2D x-ray invasive coronary angiography (ICA) remains as the most widely adopted imaging modality for CVDs diagnosis. However, in current clinical practice, it is often difficult for the cardiologists to interpret the 3D geometry of coronary vessels based on 2D planes. Moreover, due to the radiation limit, in general only two angiographic projections are acquired, providing limited information of the vessel geometry and necessitating 3D coronary tree reconstruction based only on two ICA projections. In this paper, we propose a self-supervised deep learning method called NeCA, which is based on implicit neural representation using the multiresolution hash encoder and differentiable cone-beam forward projector layer in order to achieve 3D coronary artery tree reconstruction from two projections. We validate our method using six different metrics on coronary computed tomography angiography data in terms of right coronary artery and left anterior descending respectively. The evaluation results demonstrate that our NeCA method, without 3D ground truth for supervision and large datasets for training, achieves promising performance in both vessel topology preservation and branch-connectivity maintaining compared to the supervised deep learning model.

Read more

9/10/2024

SAM-VMNet: Deep Neural Networks For Coronary Angiography Vessel Segmentation
Total Score

0

SAM-VMNet: Deep Neural Networks For Coronary Angiography Vessel Segmentation

Xueying Zeng, Baixiang Huang, Yu Luo, Guangyu Wei, Songyan He, Yushuang Shao

Coronary artery disease (CAD) is one of the most prevalent diseases in the cardiovascular field and one of the major contributors to death worldwide. Computed Tomography Angiography (CTA) images are regarded as the authoritative standard for the diagnosis of coronary artery disease, and by performing vessel segmentation and stenosis detection on CTA images, physicians are able to diagnose coronary artery disease more accurately. In order to combine the advantages of both the base model and the domain-specific model, and to achieve high-precision and fully-automatic segmentation and detection with a limited number of training samples, we propose a novel architecture, SAM-VMNet, which combines the powerful feature extraction capability of MedSAM with the advantage of the linear complexity of the visual state-space model of VM-UNet, giving it faster inferences than Vision Transformer with faster inference speed and stronger data processing capability, achieving higher segmentation accuracy and stability for CTA images. Experimental results show that the SAM-VMNet architecture performs excellently in the CTA image segmentation task, with a segmentation accuracy of up to 98.32% and a sensitivity of up to 99.33%, which is significantly better than other existing models and has stronger domain adaptability. Comprehensive evaluation of the CTA image segmentation task shows that SAM-VMNet accurately extracts the vascular trunks and capillaries, demonstrating its great potential and wide range of application scenarios for the vascular segmentation task, and also laying a solid foundation for further stenosis detection.

Read more

6/4/2024