A Non-Intrusive Neural Quality Assessment Model for Surface Electromyography Signals

Read original: arXiv:2402.05482 - Published 6/14/2024 by Cho-Yuan Lee, Kuan-Chen Wang, Kai-Chun Liu, Yu-Te Wang, Xugang Lu, Ping-Cheng Yeh, Yu Tsao
Total Score

0

🧠

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This study proposes a new model called QASE-net to predict the signal-to-noise ratio (SNR) of surface electromyography (sEMG) signals, particularly in areas near the heart where electrocardiogram (ECG) signals can contaminate the data.
  • QASE-net combines convolutional neural networks (CNN), bidirectional long short-term memory (BLSTM), and attention mechanisms to assess sEMG signal quality in an end-to-end fashion.
  • The model is evaluated on real-world sEMG and ECG data from two open-access databases, demonstrating its superior performance over previous assessment models.

Plain English Explanation

Measuring the electrical activity of muscles, known as surface electromyography (sEMG), is a valuable tool in various applications, such as prosthetic control and rehabilitation. However, in practical scenarios, particularly when measuring muscles near the heart, the presence of electrocardiogram (ECG) signals can contaminate the sEMG data, making it harder to interpret.

To address this challenge, the researchers have developed a new model called QASE-net that can predict the signal-to-noise ratio (SNR) of sEMG signals. This means the model can assess the quality of the sEMG data and identify how much the ECG signal is interfering with the muscle activity measurement.

QASE-net uses a combination of deep learning techniques, including convolutional neural networks (CNNs) to extract features from the sEMG data, bidirectional long short-term memory (BLSTM) to capture the temporal patterns, and attention mechanisms to focus on the most relevant parts of the signal. The model is trained end-to-end, meaning it learns to predict the SNR directly from the raw sEMG and ECG data.

The researchers tested QASE-net on real-world sEMG and ECG data from two publicly available databases. The results showed that QASE-net significantly outperformed previous assessment models, with lower prediction errors and higher correlations with the ground truth SNR values. This suggests that QASE-net can substantially improve the reliability and accuracy of sEMG quality assessment in practical applications, such as efficient sEMG-based cross-subject joint angle prediction, ECG-based models, hand movement recognition, and non-intrusive music audio analysis.

Technical Explanation

The researchers proposed QASE-net, a novel deep learning model for predicting the signal-to-noise ratio (SNR) of surface electromyography (sEMG) signals in the presence of electrocardiogram (ECG) interference. QASE-net combines convolutional neural networks (CNNs), bidirectional long short-term memory (BLSTM), and attention mechanisms to effectively capture the relevant features and temporal patterns in the sEMG and ECG data.

The experimental framework utilized real-world sEMG data from the Non-Invasive Adaptive Prosthetics Database and ECG data from the MIT-BIH Normal Sinus Rhythm Database. The researchers designed an end-to-end training strategy where QASE-net learns to directly predict the SNR of the sEMG signals given the raw input data.

The results demonstrated that QASE-net outperformed previous sEMG quality assessment models, exhibiting significantly reduced prediction errors and notably higher linear correlations with the ground truth SNR values. This suggests that QASE-net can substantially enhance the reliability and precision of sEMG quality assessment in practical applications, such as efficient sEMG-based cross-subject joint angle prediction, ECG-based models, hand movement recognition, and non-intrusive music audio analysis.

Critical Analysis

The study presents a compelling approach to addressing the practical challenges of sEMG signal quality assessment, particularly in areas near the heart where ECG interference is a common issue. The use of a combination of deep learning techniques, including CNNs, BLSTM, and attention mechanisms, appears to be a promising strategy for effectively capturing the relevant features and patterns in the data.

However, the authors do not discuss any potential limitations or caveats of their approach. For example, it would be interesting to know how QASE-net performs on a wider range of sEMG and ECG datasets, especially those with different characteristics or from different measurement setups. Additionally, the authors could have explored the interpretability of the model's predictions, as understanding the factors contributing to the SNR assessment could be valuable for practitioners.

Further research could also investigate the robustness of QASE-net to variations in the input data, such as different signal-to-noise ratios or different types of noise. Exploring the model's generalization capabilities and potential transfer learning applications would also be an interesting avenue for future work.

Overall, the study presents a promising approach to enhancing the reliability and precision of sEMG quality assessment, with the potential to benefit a range of applications that rely on high-quality sEMG data. By encouraging critical thinking and further research, this work can contribute to the ongoing efforts to improve the accuracy and interpretability of sEMG-based systems.

Conclusion

This study proposes QASE-net, a novel deep learning model for predicting the signal-to-noise ratio (SNR) of surface electromyography (sEMG) signals in the presence of electrocardiogram (ECG) interference. QASE-net combines convolutional neural networks, bidirectional long short-term memory, and attention mechanisms to effectively assess sEMG signal quality in an end-to-end fashion.

The experimental results demonstrate the superior performance of QASE-net over previous assessment models, with significantly reduced prediction errors and notably higher linear correlations with the ground truth SNR. These findings suggest that QASE-net has the potential to substantially improve the reliability and precision of sEMG quality assessment in practical applications, such as efficient sEMG-based cross-subject joint angle prediction, ECG-based models, hand movement recognition, and non-intrusive music audio analysis.

While the study presents a promising approach, further research is needed to explore the model's limitations, robustness, and potential for broader applications. By continuing to refine and validate QASE-net, researchers can contribute to the ongoing efforts to enhance the accuracy and interpretability of sEMG-based systems, ultimately benefiting various fields that rely on high-quality muscle activity measurements.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🧠

Total Score

0

A Non-Intrusive Neural Quality Assessment Model for Surface Electromyography Signals

Cho-Yuan Lee, Kuan-Chen Wang, Kai-Chun Liu, Yu-Te Wang, Xugang Lu, Ping-Cheng Yeh, Yu Tsao

In practical scenarios involving the measurement of surface electromyography (sEMG) in muscles, particularly those areas near the heart, one of the primary sources of contamination is the presence of electrocardiogram (ECG) signals. To assess the quality of real-world sEMG data more effectively, this study proposes QASE-net, a new non-intrusive model that predicts the SNR of sEMG signals. QASE-net combines CNN-BLSTM with attention mechanisms and follows an end-to-end training strategy. Our experimental framework utilizes real-world sEMG and ECG data from two open-access databases, the Non-Invasive Adaptive Prosthetics Database and the MIT-BIH Normal Sinus Rhythm Database, respectively. The experimental results demonstrate the superiority of QASE-net over the previous assessment model, exhibiting significantly reduced prediction errors and notably higher linear correlations with the ground truth. These findings show the potential of QASE-net to substantially enhance the reliability and precision of sEMG quality assessment in practical applications.

Read more

6/14/2024

Efficient sEMG-based Cross-Subject Joint Angle Estimation via Hierarchical Spiking Attentional Feature Decomposition Network
Total Score

0

Efficient sEMG-based Cross-Subject Joint Angle Estimation via Hierarchical Spiking Attentional Feature Decomposition Network

Xin Zhou, Chuang Lin, Can Wang, Xiaojiang Peng

As human-machine interaction systems are developing towards lightweight and pervasive direction, the role of simultaneous and proportional control (SPC) in human-machine interaction becomes increasingly prominent. However, existing continuous joint angle prediction algorithms based on surface electromyography (sEMG) typically incur high inference costs or are only applicable to specific subjects rather than cross-subject scenarios. Therefore, we proposed a hierarchical Spiking Attentional FEature decomposition Network (SAFE-Net) in order to reduce inference costs and improve recognition accuracy in cross-subject scenarios. This network first encodes the sEMG signals into neural spiking forms through a Spiking Sparse Attention Encoder (SSAE). The compressed features are then decomposed into kinematic features and biological features by a Spiking Attentional Feature Decomposition (SAFD) module. Finally, the kinematic features and biological features are decoded into joint angle values and subject identity, respectively. We validated the effectiveness of SAFE-Net on two datasets (SIAT-DB1 and SIAT-DB2) and compared it with two state-of-the-art methods, Informer and Spikformer. Experimental results demonstrate that, on the one hand, SSAE saves 39.1% and 37.5% power consumption respectively over them in terms of inference costs. On the other hand, SAFE-Net outperforms Informer and Spikformer in recognition accuracy on both datasets. This study showcased that the proposed SAFE-Net can provide accurate predictions in cross-subject scenarios, offering a promising vision for precise continuous control of lower limb rehabilitation exoskeleton robots.

Read more

7/9/2024

An LSTM Feature Imitation Network for Hand Movement Recognition from sEMG Signals
Total Score

0

An LSTM Feature Imitation Network for Hand Movement Recognition from sEMG Signals

Chuheng Wu, S. Farokh Atashzar, Mohammad M. Ghassemi, Tuka Alhanai

Surface Electromyography (sEMG) is a non-invasive signal that is used in the recognition of hand movement patterns, the diagnosis of diseases, and the robust control of prostheses. Despite the remarkable success of recent end-to-end Deep Learning approaches, they are still limited by the need for large amounts of labeled data. To alleviate the requirement for big data, researchers utilize Feature Engineering, which involves decomposing the sEMG signal into several spatial, temporal, and frequency features. In this paper, we propose utilizing a feature-imitating network (FIN) for closed-form temporal feature learning over a 300ms signal window on Ninapro DB2, and applying it to the task of 17 hand movement recognition. We implement a lightweight LSTM-FIN network to imitate four standard temporal features (entropy, root mean square, variance, simple square integral). We then explore transfer learning capabilities by applying the pre-trained LSTM-FIN for tuning to a downstream hand movement recognition task. We observed that the LSTM network can achieve up to 99% R2 accuracy in feature reconstruction and 80% accuracy in hand movement recognition. Our results also showed that the model can be robustly applied for both within- and cross-subject movement recognition, as well as simulated low-latency environments. Overall, our work demonstrates the potential of the FIN modeling paradigm in data-scarce scenarios for sEMG signal processing.

Read more

5/31/2024

ECG Semantic Integrator (ESI): A Foundation ECG Model Pretrained with LLM-Enhanced Cardiological Text
Total Score

0

ECG Semantic Integrator (ESI): A Foundation ECG Model Pretrained with LLM-Enhanced Cardiological Text

Han Yu, Peikun Guo, Akane Sano

The utilization of deep learning on electrocardiogram (ECG) analysis has brought the advanced accuracy and efficiency of cardiac healthcare diagnostics. By leveraging the capabilities of deep learning in semantic understanding, especially in feature extraction and representation learning, this study introduces a new multimodal contrastive pretaining framework that aims to improve the quality and robustness of learned representations of 12-lead ECG signals. Our framework comprises two key components, including Cardio Query Assistant (CQA) and ECG Semantics Integrator(ESI). CQA integrates a retrieval-augmented generation (RAG) pipeline to leverage large language models (LLMs) and external medical knowledge to generate detailed textual descriptions of ECGs. The generated text is enriched with information about demographics and waveform patterns. ESI integrates both contrastive and captioning loss to pretrain ECG encoders for enhanced representations. We validate our approach through various downstream tasks, including arrhythmia detection and ECG-based subject identification. Our experimental results demonstrate substantial improvements over strong baselines in these tasks. These baselines encompass supervised and self-supervised learning methods, as well as prior multimodal pretraining approaches.

Read more

5/31/2024