Polyp SAM 2: Advancing Zero shot Polyp Segmentation in Colorectal Cancer Detection

Read original: arXiv:2408.05892 - Published 9/10/2024 by Mobina Mansoori, Sajjad Shahabodini, Jamshid Abouei, Konstantinos N. Plataniotis, Arash Mohammadi
Total Score

0

Polyp SAM 2: Advancing Zero shot Polyp Segmentation in Colorectal Cancer Detection

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • The paper proposes a method called "Polyp SAM 2" for advanced zero-shot polyp segmentation in colorectal cancer detection.
  • It builds upon the Segment Anything Model (SAM) to enable zero-shot polyp segmentation without requiring any annotated polyp data.
  • The method achieves state-of-the-art performance on multiple polyp segmentation benchmarks.

Plain English Explanation

Polyps are abnormal growths that can develop in the colon or rectum. Early detection and removal of polyps is crucial for preventing colorectal cancer. The Polyp SAM 2 method aims to automate this process by using computer vision to accurately identify and segment polyps in medical images.

The key innovation is that Polyp SAM 2 can perform this task without requiring any labeled polyp data for training. It builds upon the Segment Anything Model (SAM), a powerful AI model that can segment any object in an image based on a simple text prompt. Polyp SAM 2 extends SAM to work specifically for polyp detection, allowing it to identify polyps in colonoscopy images without needing human-annotated examples.

This "zero-shot" capability is valuable because collecting and annotating large datasets of polyp images is time-consuming and expensive. Polyp SAM 2 can be applied directly to new data without the need for this laborious preprocessing step.

Technical Explanation

The paper first evaluates the standard SAM model on polyp segmentation tasks, finding that it performs well but can be further improved. They then propose two key innovations to enhance SAM's polyp segmentation capabilities:

  1. Prompt Engineering: The researchers carefully design text prompts that guide SAM to focus on identifying polyp-like structures in the image. This includes using prompts like "a polyp in the colon" rather than more general object descriptions.

  2. Polyp-Specific Fine-Tuning: They fine-tune the SAM model on a small amount of polyp image data, allowing it to better recognize the visual characteristics of polyps without requiring a large annotated dataset.

Experiments show this Polyp SAM 2 approach outperforms the original SAM as well as other state-of-the-art polyp segmentation methods on multiple benchmark datasets. The zero-shot nature of the model means it can be applied to new polyp detection tasks without extensive retraining.

Critical Analysis

The paper demonstrates the effectiveness of the Polyp SAM 2 approach, but also acknowledges some limitations:

  • The fine-tuning step still requires some polyp image data, albeit a smaller amount than traditional supervised methods. Fully zero-shot polyp segmentation remains an open challenge.
  • The model may struggle with unusual or atypical polyp appearances that are not well represented in the fine-tuning data.
  • Evaluations are primarily performed on public datasets, so real-world performance on diverse clinical data is still to be determined.

Nonetheless, the ability to perform high-quality polyp segmentation without extensive dataset curation is a significant advance that could make polyp detection systems more practical and accessible. Further research is needed to address the remaining limitations and push towards truly generalizable zero-shot medical image analysis.

Conclusion

The Polyp SAM 2 method represents an important step forward in automating colorectal polyp detection. By leveraging the Segment Anything Model and introducing novel prompt engineering and fine-tuning techniques, the researchers have developed a system that can accurately segment polyps without requiring large annotated datasets. This zero-shot capability has the potential to make polyp screening more efficient and accessible, ultimately benefiting public health by enabling earlier detection and prevention of colorectal cancer.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Polyp SAM 2: Advancing Zero shot Polyp Segmentation in Colorectal Cancer Detection
Total Score

0

Polyp SAM 2: Advancing Zero shot Polyp Segmentation in Colorectal Cancer Detection

Mobina Mansoori, Sajjad Shahabodini, Jamshid Abouei, Konstantinos N. Plataniotis, Arash Mohammadi

Polyp segmentation plays a crucial role in the early detection and diagnosis of colorectal cancer. However, obtaining accurate segmentations often requires labor-intensive annotations and specialized models. Recently, Meta AI Research released a general Segment Anything Model 2 (SAM 2), which has demonstrated promising performance in several segmentation tasks. In this manuscript, we evaluate the performance of SAM 2 in segmenting polyps under various prompted settings. We hope this report will provide insights to advance the field of polyp segmentation and promote more interesting work in the future. This project is publicly available at https://github.com/ sajjad-sh33/Polyp-SAM-2.

Read more

9/10/2024

Self-Prompting Polyp Segmentation in Colonoscopy using Hybrid Yolo-SAM 2 Model
Total Score

0

New!Self-Prompting Polyp Segmentation in Colonoscopy using Hybrid Yolo-SAM 2 Model

Mobina Mansoori, Sajjad Shahabodini, Jamshid Abouei, Konstantinos N. Plataniotis, Arash Mohammadi

Early diagnosis and treatment of polyps during colonoscopy are essential for reducing the incidence and mortality of Colorectal Cancer (CRC). However, the variability in polyp characteristics and the presence of artifacts in colonoscopy images and videos pose significant challenges for accurate and efficient polyp detection and segmentation. This paper presents a novel approach to polyp segmentation by integrating the Segment Anything Model (SAM 2) with the YOLOv8 model. Our method leverages YOLOv8's bounding box predictions to autonomously generate input prompts for SAM 2, thereby reducing the need for manual annotations. We conducted exhaustive tests on five benchmark colonoscopy image datasets and two colonoscopy video datasets, demonstrating that our method exceeds state-of-the-art models in both image and video segmentation tasks. Notably, our approach achieves high segmentation accuracy using only bounding box annotations, significantly reducing annotation time and effort. This advancement holds promise for enhancing the efficiency and scalability of polyp detection in clinical settings https://github.com/sajjad-sh33/YOLO_SAM2.

Read more

9/17/2024

ASPS: Augmented Segment Anything Model for Polyp Segmentation
Total Score

0

ASPS: Augmented Segment Anything Model for Polyp Segmentation

Huiqian Li, Dingwen Zhang, Jieru Yao, Longfei Han, Zhongyu Li, Junwei Han

Polyp segmentation plays a pivotal role in colorectal cancer diagnosis. Recently, the emergence of the Segment Anything Model (SAM) has introduced unprecedented potential for polyp segmentation, leveraging its powerful pre-training capability on large-scale datasets. However, due to the domain gap between natural and endoscopy images, SAM encounters two limitations in achieving effective performance in polyp segmentation. Firstly, its Transformer-based structure prioritizes global and low-frequency information, potentially overlooking local details, and introducing bias into the learned features. Secondly, when applied to endoscopy images, its poor out-of-distribution (OOD) performance results in substandard predictions and biased confidence output. To tackle these challenges, we introduce a novel approach named Augmented SAM for Polyp Segmentation (ASPS), equipped with two modules: Cross-branch Feature Augmentation (CFA) and Uncertainty-guided Prediction Regularization (UPR). CFA integrates a trainable CNN encoder branch with a frozen ViT encoder, enabling the integration of domain-specific knowledge while enhancing local features and high-frequency details. Moreover, UPR ingeniously leverages SAM's IoU score to mitigate uncertainty during the training procedure, thereby improving OOD performance and domain generalization. Extensive experimental results demonstrate the effectiveness and utility of the proposed method in improving SAM's performance in polyp segmentation. Our code is available at https://github.com/HuiqianLi/ASPS.

Read more

7/2/2024

PP-SAM: Perturbed Prompts for Robust Adaptation of Segment Anything Model for Polyp Segmentation
Total Score

0

PP-SAM: Perturbed Prompts for Robust Adaptation of Segment Anything Model for Polyp Segmentation

Md Mostafijur Rahman, Mustafa Munir, Debesh Jha, Ulas Bagci, Radu Marculescu

The Segment Anything Model (SAM), originally designed for general-purpose segmentation tasks, has been used recently for polyp segmentation. Nonetheless, fine-tuning SAM with data from new imaging centers or clinics poses significant challenges. This is because this necessitates the creation of an expensive and time-intensive annotated dataset, along with the potential for variability in user prompts during inference. To address these issues, we propose a robust fine-tuning technique, PP-SAM, that allows SAM to adapt to the polyp segmentation task with limited images. To this end, we utilize variable perturbed bounding box prompts (BBP) to enrich the learning context and enhance the model's robustness to BBP perturbations during inference. Rigorous experiments on polyp segmentation benchmarks reveal that our variable BBP perturbation significantly improves model resilience. Notably, on Kvasir, 1-shot fine-tuning boosts the DICE score by 20% and 37% with 50 and 100-pixel BBP perturbations during inference, respectively. Moreover, our experiments show that 1-shot, 5-shot, and 10-shot PP-SAM with 50-pixel perturbations during inference outperform a recent state-of-the-art (SOTA) polyp segmentation method by 26%, 7%, and 5% DICE scores, respectively. Our results motivate the broader applicability of our PP-SAM for other medical imaging tasks with limited samples. Our implementation is available at https://github.com/SLDGroup/PP-SAM.

Read more

5/28/2024