Quantum optimization algorithms for CT image segmentation from X-ray data

Read original: arXiv:2306.05522 - Published 9/17/2024 by Kyungtaek Jun
Total Score

0

🛠️

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Computed tomography (CT) is an important medical imaging technique used to analyze the internal structure of the human body.
  • Previous methods required separate image segmentation after acquiring reconstructed CT images, which could introduce errors from both reconstruction and segmentation algorithms.
  • This paper introduces a new approach using a quantum optimization algorithm called quadratic unconstrained binary optimization (QUBO) to acquire segmented CT images directly from X-ray projection data.

Plain English Explanation

Computed tomography (CT) scanning is a widely used medical imaging technique that allows doctors to see detailed images of the inside of the human body. In the past, getting these detailed CT images involved two separate steps: first, reconstructing the image from the raw X-ray data, and then using a separate image segmentation process to identify and separate the different structures within the image.

This new approach uses a quantum optimization algorithm called QUBO to skip the separate segmentation step and instead acquire the segmented CT images directly from the original X-ray data. The QUBO algorithm is able to minimize the differences between the actual X-ray data and the X-ray data that would be generated from the final segmented CT image. This allows the segmented CT image to be obtained in a single step, without the potential errors that could occur from the separate reconstruction and segmentation processes.

The researchers tested this approach using real-world X-ray data and a hybrid solver system developed by D-Wave, a company that specializes in quantum computing hardware and software.

Technical Explanation

This paper presents a new approach for acquiring segmented CT images directly from X-ray projection data using a quantum optimization algorithm called quadratic unconstrained binary optimization (QUBO).

Previous methods required first reconstructing the CT image from the X-ray data, and then applying a separate image segmentation algorithm to identify the different structures within the image. This two-step process was susceptible to errors introduced by both the reconstruction and segmentation algorithms.

The QUBO algorithm used in this new approach is able to minimize the discrepancies between the actual X-ray sinograms (the raw X-ray data) and the sinograms that would be generated from the final segmented CT image using the Radon transform. By optimizing this objective function, the QUBO algorithm can acquire the segmented CT image in a single step, without the need for a separate segmentation process.

The researchers utilized D-Wave's hybrid solver system, which combines classical and quantum computing approaches, to verify the performance of this QUBO-based segmentation method on real-world X-ray data.

Critical Analysis

The paper presents a promising new approach for CT image segmentation that avoids the potential errors introduced by the traditional two-step reconstruction and segmentation process. The use of the QUBO quantum optimization algorithm to directly acquire segmented images from X-ray data is an interesting and innovative technique.

However, the paper does not provide a detailed evaluation of the segmentation accuracy or computational efficiency of the QUBO-based approach compared to other state-of-the-art segmentation methods. It would be helpful to see more quantitative results and comparisons to better assess the practical benefits and limitations of this new technique.

Additionally, the reliance on D-Wave's specialized quantum hardware may limit the accessibility and scalability of this approach for wider adoption. Further research is needed to explore the feasibility of implementing the QUBO algorithm on more widely available classical or quantum computing resources.

Conclusion

This paper introduces a novel quantum optimization-based approach for acquiring segmented CT images directly from X-ray projection data. By using the QUBO algorithm to minimize the discrepancies between the actual and simulated X-ray sinograms, this method is able to obtain the segmented CT image in a single step, avoiding the potential errors introduced by traditional reconstruction and segmentation pipelines.

While further research is needed to fully evaluate the performance and practical applications of this technique, the paper demonstrates the potential of quantum computing methods to improve medical imaging workflows and enable more accurate and efficient analysis of the human body's internal structure.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🛠️

Total Score

0

Quantum optimization algorithms for CT image segmentation from X-ray data

Kyungtaek Jun

Computed tomography (CT) is an important imaging technique used in medical analysis of the internal structure of the human body. Previously, image segmentation methods were required after acquiring reconstructed CT images to obtain segmented CT images which made it susceptible to errors from both reconstruction and segmentation algorithms. However, this paper introduces a new approach using an advanced quantum optimization algorithm called quadratic unconstrained binary optimization (QUBO). This algorithm enables acquisition of segmented CT images from X-ray projection data with minimized discrepancies between experimentally obtained sinograms and quantized sinograms derived from quantized segmented CT images using the Radon transform. This study utilized D-Wave's hybrid solver system for verification on real-world X-ray data.

Read more

9/17/2024

🤷

Total Score

0

Q-Seg: Quantum Annealing-Based Unsupervised Image Segmentation

Supreeth Mysore Venkatesh, Antonio Macaluso, Marlon Nuske, Matthias Klusch, Andreas Dengel

We present Q-Seg, a novel unsupervised image segmentation method based on quantum annealing, tailored for existing quantum hardware. We formulate the pixel-wise segmentation problem, which assimilates spectral and spatial information of the image, as a graph-cut optimization task. Our method efficiently leverages the interconnected qubit topology of the D-Wave Advantage device, offering superior scalability over existing quantum approaches and outperforming several tested state-of-the-art classical methods. Empirical evaluations on synthetic datasets have shown that Q-Seg has better runtime performance than the state-of-the-art classical optimizer Gurobi. The method has also been tested on earth observation image segmentation, a critical area with noisy and unreliable annotations. In the era of noisy intermediate-scale quantum, Q-Seg emerges as a reliable contender for real-world applications in comparison to advanced techniques like Segment Anything. Consequently, Q-Seg offers a promising solution using available quantum hardware, especially in situations constrained by limited labeled data and the need for efficient computational runtime.

Read more

9/6/2024

Qubit-efficient Variational Quantum Algorithms for Image Segmentation
Total Score

0

Qubit-efficient Variational Quantum Algorithms for Image Segmentation

Supreeth Mysore Venkatesh, Antonio Macaluso, Marlon Nuske, Matthias Klusch, Andreas Dengel

Quantum computing is expected to transform a range of computational tasks beyond the reach of classical algorithms. In this work, we examine the application of variational quantum algorithms (VQAs) for unsupervised image segmentation to partition images into separate semantic regions. Specifically, we formulate the task as a graph cut optimization problem and employ two established qubit-efficient VQAs, which we refer to as Parametric Gate Encoding (PGE) and Ancilla Basis Encoding (ABE), to find the optimal segmentation mask. In addition, we propose Adaptive Cost Encoding (ACE), a new approach that leverages the same circuit architecture as ABE but adopts a problem-dependent cost function. We benchmark PGE, ABE and ACE on synthetically generated images, focusing on quality and trainability. ACE shows consistently faster convergence in training the parameterized quantum circuits in comparison to PGE and ABE. Furthermore, we provide a theoretical analysis of the scalability of these approaches against the Quantum Approximate Optimization Algorithm (QAOA), showing a significant cutback in the quantum resources, especially in the number of qubits that logarithmically depends on the number of pixels. The results validate the strengths of ACE, while concurrently highlighting its inherent limitations and challenges. This paves way for further research in quantum-enhanced computer vision.

Read more

5/24/2024

DiffuX2CT: Diffusion Learning to Reconstruct CT Images from Biplanar X-Rays
Total Score

0

DiffuX2CT: Diffusion Learning to Reconstruct CT Images from Biplanar X-Rays

Xuhui Liu, Zhi Qiao, Runkun Liu, Hong Li, Juan Zhang, Xiantong Zhen, Zhen Qian, Baochang Zhang

Computed tomography (CT) is widely utilized in clinical settings because it delivers detailed 3D images of the human body. However, performing CT scans is not always feasible due to radiation exposure and limitations in certain surgical environments. As an alternative, reconstructing CT images from ultra-sparse X-rays offers a valuable solution and has gained significant interest in scientific research and medical applications. However, it presents great challenges as it is inherently an ill-posed problem, often compromised by artifacts resulting from overlapping structures in X-ray images. In this paper, we propose DiffuX2CT, which models CT reconstruction from orthogonal biplanar X-rays as a conditional diffusion process. DiffuX2CT is established with a 3D global coherence denoising model with a new, implicit conditioning mechanism. We realize the conditioning mechanism by a newly designed tri-plane decoupling generator and an implicit neural decoder. By doing so, DiffuX2CT achieves structure-controllable reconstruction, which enables 3D structural information to be recovered from 2D X-rays, therefore producing faithful textures in CT images. As an extra contribution, we collect a real-world lumbar CT dataset, called LumbarV, as a new benchmark to verify the clinical significance and performance of CT reconstruction from X-rays. Extensive experiments on this dataset and three more publicly available datasets demonstrate the effectiveness of our proposal.

Read more

7/19/2024