  • This paper explores efficient fine-tuning strategies for segmenting fetal heads in low-resource settings using the U-Net architecture.
  • The researchers investigate various fine-tuning approaches to improve performance in scenarios with limited training data.
  • The study aims to provide insights into effective transfer learning and training techniques for medical image segmentation tasks.

Plain English Explanation

In the field of medical imaging, segmenting (or identifying) the fetal head in ultrasound scans is an important task. This can help doctors monitor the growth and development of the baby during pregnancy. However, this task can be challenging, especially in low-resource settings where there may be limited training data available.

To address this, the researchers in this paper studied different ways of "fine-tuning" a popular deep learning model called U-Net. Fine-tuning involves taking a pre-trained model and adapting it to a new task or dataset, rather than training the model from scratch.

The researchers explored various fine-tuning strategies to see which ones work best for segmenting fetal heads when there is limited training data available. They compared different approaches, such as freezing certain layers of the model or using different optimization techniques.

The goal was to find efficient ways to adapt the U-Net model to accurately segment fetal heads, even in situations where there is not a lot of labeled training data available. This could be valuable for healthcare providers in low-resource regions who need to monitor fetal development but may have access to limited medical imaging data.

Technical Explanation

The paper focuses on the task of segmenting the fetal head in ultrasound images using the U-Net architecture. U-Net is a popular convolutional neural network model widely used for medical image segmentation tasks.

The researchers investigated several fine-tuning strategies to improve the performance of U-Net for fetal head segmentation in low-resource settings, where the availability of labeled training data is limited. The fine-tuning approaches explored include:

  1. Full fine-tuning: Fully fine-tuning all layers of the pre-trained U-Net model.
  2. Partial fine-tuning: Selectively fine-tuning only the later layers of the U-Net model, while freezing the earlier layers.
  3. Gradient-based fine-tuning: Using a different optimization algorithm (Rectified Adam) for fine-tuning the model.

The researchers evaluated these fine-tuning strategies on a fetal ultrasound dataset and compared their performance to a U-Net model trained from scratch. They used common segmentation metrics, such as Dice score and Jaccard index, to assess the model's accuracy.

The results showed that the partial fine-tuning approach, where only the later layers of the U-Net model were fine-tuned, outperformed the other strategies and the baseline model trained from scratch. This suggests that selectively fine-tuning the model can be an effective way to leverage pre-trained knowledge and improve segmentation performance in low-resource settings.

Critical Analysis

The paper provides valuable insights into efficient fine-tuning strategies for medical image segmentation tasks, particularly in the context of fetal head segmentation from ultrasound scans. The researchers' focus on low-resource settings is noteworthy, as it addresses a common challenge faced by healthcare providers in developing regions.

One potential limitation of the study is the relatively small size of the fetal ultrasound dataset used for evaluation. While the researchers acknowledge this, it would be beneficial to validate the findings on larger and more diverse datasets to ensure the generalizability of the results.

Additionally, the paper does not explore the impact of the pre-trained model's initialization on the fine-tuning performance. Investigating the role of different pre-trained weights or architectures could provide further insights into the most effective fine-tuning strategies.

Future research could also delve into the interpretability of the fine-tuned models, shedding light on the specific features and representations learned during the fine-tuning process. This could lead to a better understanding of the underlying mechanisms driving the improved segmentation performance.

Conclusion

This paper presents an empirical study on efficient fine-tuning strategies for segmenting fetal heads using the U-Net architecture in low-resource settings. The findings suggest that selectively fine-tuning the later layers of the pre-trained U-Net model can be an effective approach to leveraging pre-existing knowledge and improving segmentation accuracy, even when limited training data is available.

The insights from this research could be valuable for healthcare providers and medical imaging researchers working on developing robust and efficient segmentation models, particularly in resource-constrained environments. The strategies explored in this paper may have broader applicability to other medical image analysis tasks and could contribute to advancing the field of low-resource machine learning for healthcare.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Segmenting Fetal Head with Efficient Fine-tuning Strategies in Low-resource Settings: an empirical study with U-Net
Total Score

0

Segmenting Fetal Head with Efficient Fine-tuning Strategies in Low-resource Settings: an empirical study with U-Net

Fangyijie Wang, Gu'enol'e Silvestre, Kathleen M. Curran

Accurate measurement of fetal head circumference is crucial for estimating fetal growth during routine prenatal screening. Prior to measurement, it is necessary to accurately identify and segment the region of interest, specifically the fetal head, in ultrasound images. Recent advancements in deep learning techniques have shown significant progress in segmenting the fetal head using encoder-decoder models. Among these models, U-Net has become a standard approach for accurate segmentation. However, training an encoder-decoder model can be a time-consuming process that demands substantial computational resources. Moreover, fine-tuning these models is particularly challenging when there is a limited amount of data available. There are still no best-practice guidelines for optimal fine-tuning of U-net for fetal ultrasound image segmentation. This work summarizes existing fine-tuning strategies with various backbone architectures, model components, and fine-tuning strategies across ultrasound data from Netherlands, Spain, Malawi, Egypt and Algeria. Our study shows that (1) fine-tuning U-Net leads to better performance than training from scratch, (2) fine-tuning strategies in decoder are superior to other strategies, (3) network architecture with less number of parameters can achieve similar or better performance. We also demonstrate the effectiveness of fine-tuning strategies in low-resource settings and further expand our experiments into few-shot learning. Lastly, we publicly released our code and specific fine-tuned weights.

Read more

7/30/2024

🖼️

Total Score

0

Evaluate Fine-tuning Strategies for Fetal Head Ultrasound Image Segmentation with U-Net

Fangyijie Wang, Gu'enol'e Silvestre, Kathleen M. Curran

Fetal head segmentation is a crucial step in measuring the fetal head circumference (HC) during gestation, an important biometric in obstetrics for monitoring fetal growth. However, manual biometry generation is time-consuming and results in inconsistent accuracy. To address this issue, convolutional neural network (CNN) models have been utilized to improve the efficiency of medical biometry. But training a CNN network from scratch is a challenging task, we proposed a Transfer Learning (TL) method. Our approach involves fine-tuning (FT) a U-Net network with a lightweight MobileNet as the encoder to perform segmentation on a set of fetal head ultrasound (US) images with limited effort. This method addresses the challenges associated with training a CNN network from scratch. It suggests that our proposed FT strategy yields segmentation performance that is comparable when trained with a reduced number of parameters by 85.8%. And our proposed FT strategy outperforms other strategies with smaller trainable parameter sizes below 4.4 million. Thus, we contend that it can serve as a dependable FT approach for reducing the size of models in medical image analysis. Our key findings highlight the importance of the balance between model performance and size in developing Artificial Intelligence (AI) applications by TL methods. Code is available at https://github.com/13204942/FT_Methods_for_Fetal_Head_Segmentation.

Read more

8/2/2024

🛸

Total Score

0

Modifying the U-Net's Encoder-Decoder Architecture for Segmentation of Tumors in Breast Ultrasound Images

Sina Derakhshandeh, Ali Mahloojifar

Segmentation is one of the most significant steps in image processing. Segmenting an image is a technique that makes it possible to separate a digital image into various areas based on the different characteristics of pixels in the image. In particular, segmentation of breast ultrasound images is widely used for cancer identification. As a result of image segmentation, it is possible to make early diagnoses of diseases via medical images in a very effective way. Due to various ultrasound artifacts and noises, including speckle noise, low signal-to-noise ratio, and intensity heterogeneity, the process of accurately segmenting medical images, such as ultrasound images, is still a challenging task. In this paper, we present a new method to improve the accuracy and effectiveness of breast ultrasound image segmentation. More precisely, we propose a Neural Network (NN) based on U-Net and an encoder-decoder architecture. By taking U-Net as the basis, both encoder and decoder parts are developed by combining U-Net with other Deep Neural Networks (Res-Net and MultiResUNet) and introducing a new approach and block (Co-Block), which preserves as much as possible the low-level and the high-level features. The designed network is evaluated using the Breast Ultrasound Images (BUSI) Dataset. It consists of 780 images and the images are categorized into three classes, which are normal, benign, and malignant. According to our extensive evaluations of a public breast ultrasound dataset, the designed network segments the breast lesions more accurately than other state-of-the-art deep learning methods. With only 8.88M parameters, our network (CResU-Net) obtained 76.88%, 71.5%, 90.3%, and 97.4% in terms of Dice similarity coefficients (DSC), Intersection over Union (IoU), Area under curve (AUC), and global accuracy (ACC), respectively, on BUSI dataset.

Read more

9/4/2024

Enhancing Generalized Fetal Brain MRI Segmentation using A Cascade Network with Depth-wise Separable Convolution and Attention Mechanism
Total Score

0

Enhancing Generalized Fetal Brain MRI Segmentation using A Cascade Network with Depth-wise Separable Convolution and Attention Mechanism

Zhigao Cai, Xing-Ming Zhao

Automatic segmentation of the fetal brain is still challenging due to the health state of fetal development, motion artifacts, and variability across gestational ages, since existing methods rely on high-quality datasets of healthy fetuses. In this work, we propose a novel cascade network called CasUNext to enhance the accuracy and generalization of fetal brain MRI segmentation. CasUNext incorporates depth-wise separable convolution, attention mechanisms, and a two-step cascade architecture for efficient high-precision segmentation. The first network localizes the fetal brain region, while the second network focuses on detailed segmentation. We evaluate CasUNext on 150 fetal MRI scans between 20 to 36 weeks from two scanners made by Philips and Siemens including axial, coronal, and sagittal views, and also validated on a dataset of 50 abnormal fetuses. Results demonstrate that CasUNext achieves improved segmentation performance compared to U-Nets and other state-of-the-art approaches. It obtains an average Dice coefficient of 96.1% and mean intersection over union of 95.9% across diverse scenarios. CasUNext shows promising capabilities for handling the challenges of multi-view fetal MRI and abnormal cases, which could facilitate various quantitative analyses and apply to multi-site data.

Read more

5/27/2024