  • This paper presents a collaborative robotic system for cancer detection through tissue viscoelastic characterization.
  • The system uses a robotic arm to perform palpation and measure the viscoelastic properties of tissue samples.
  • The goal is to enable early cancer detection by identifying differences in the viscoelastic behavior of healthy and cancerous tissues.

Plain English Explanation

The paper describes a new robotic system designed to help detect cancer. The system uses a robotic arm to gently touch and examine tissue samples, measuring their viscoelastic properties - that is, how the tissue stretches and bounces back.

The key idea is that cancerous tissues often have different viscoelastic properties compared to healthy tissues. By precisely measuring these differences, the researchers hope to develop a new way to detect cancer early, before it can be felt or seen. This could lead to faster diagnoses and better treatment outcomes for patients.

The system combines a robotic arm, sensors, and software to automatically characterize the viscoelastic behavior of tissue samples. This allows the researchers to analyze the data and potentially identify patterns that could distinguish healthy from cancerous tissues.

Overall, the goal is to create a more objective and quantitative way to detect cancer through robotized palpation, leveraging advances in digital perception technologies and variable impedance control.

Technical Explanation

The paper proposes a collaborative robotic system for cancer detection through online tissue viscoelastic characterization. The system consists of a robotic arm equipped with a compliant end-effector and force/torque sensors to perform palpation and measure the viscoelastic properties of tissue samples.

The key technical aspects include:

  1. Passively bendable compliant tactile palm for safe and gentle tissue interaction.
  2. Online viscoelastic parameter estimation using a passive variable impedance control strategy.
  3. Integration of the robotic system with digital perceptual technologies for enhanced tissue analysis.

The authors demonstrate the system's capabilities through a series of experiments, including a comprehensive robotic cholecystectomy dataset for validating the viscoelastic characterization approach.

Critical Analysis

The paper presents a promising approach for early cancer detection using a collaborative robotic system. However, some potential limitations and areas for further research are worth considering:

  • The experiments were conducted on limited tissue samples, and more extensive validation on a broader range of healthy and cancerous tissues would be necessary to assess the generalizability of the approach.
  • The paper does not provide detailed information on the sensitivity and specificity of the viscoelastic characterization method for cancer detection, which would be crucial for evaluating its clinical utility.
  • The integration of digital perceptual technologies, while promising, may introduce additional complexity and potential sources of error that should be carefully examined.
  • The cost and practical implementation of the robotic system in a clinical setting may be a concern, and the researchers should consider ways to optimize the system's design and accessibility.

Overall, the paper presents an innovative approach that leverages robotics and digital technologies to advance cancer detection. Further research and validation will be necessary to fully assess the clinical viability and impact of this system.

Conclusion

This paper describes a collaborative robotic system for early cancer detection through the online characterization of tissue viscoelastic properties. The key innovation is the use of a robotic arm equipped with advanced sensors and control strategies to perform palpation and quantify the mechanical behavior of tissue samples.

The researchers aim to leverage this technology to identify differences in the viscoelastic properties of healthy and cancerous tissues, potentially enabling earlier and more accurate cancer detection. While the initial results are promising, further validation and optimization will be necessary to assess the clinical feasibility and impact of this approach.

Nonetheless, this work represents an exciting advancement in the integration of robotics, digital perception, and medical diagnostics, with the potential to improve patient outcomes through more effective cancer screening and early intervention.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Towards Robotised Palpation for Cancer Detection through Online Tissue Viscoelastic Characterisation with a Collaborative Robotic Arm
Total Score

0

Towards Robotised Palpation for Cancer Detection through Online Tissue Viscoelastic Characterisation with a Collaborative Robotic Arm

Luca Beber, Edoardo Lamon, Giacomo Moretti, Daniele Fontanelli, Matteo Saveriano, Luigi Palopoli

This paper introduces a new method for estimating the penetration of the end effector and the parameters of a soft body using a collaborative robotic arm. This is possible using the dimensionality reduction method that simplifies the Hunt-Crossley model. The parameters can be found without a force sensor thanks to the information of the robotic arm controller. To achieve an online estimation, an extended Kalman filter is employed, which embeds the contact dynamic model. The algorithm is tested with various types of silicone, including samples with hard intrusions to simulate cancerous cells within a soft tissue. The results indicate that this technique can accurately determine the parameters and estimate the penetration of the end effector into the soft body. These promising preliminary results demonstrate the potential for robots to serve as an effective tool for early-stage cancer diagnostics.

Read more

4/16/2024

SeeBelow: Sub-dermal 3D Reconstruction of Tumors with Surgical Robotic Palpation and Tactile Exploration
Total Score

0

SeeBelow: Sub-dermal 3D Reconstruction of Tumors with Surgical Robotic Palpation and Tactile Exploration

Raghava Uppuluri, Abhinaba Bhattacharjee, Sohel Anwar, Yu She

Surgical scene understanding in Robot-assisted Minimally Invasive Surgery (RMIS) is highly reliant on visual cues and lacks tactile perception. Force-modulated surgical palpation with tactile feedback is necessary for localization, geometry/depth estimation, and dexterous exploration of abnormal stiff inclusions in subsurface tissue layers. Prior works explored surface-level tissue abnormalities or single layered tissue-tumor embeddings with more than 300 palpations for dense 2D stiffness mapping. Our approach focuses on 3D reconstructions of sub-dermal tumor surface profiles in multi-layered tissue (skin-fat-muscle) using a visually-guided novel tactile navigation policy. A robotic palpation probe with tri-axial force sensing was leveraged for tactile exploration of the phantom. From a surface mesh of the surgical region initialized from a depth camera, the policy explores a surgeon's region of interest through palpation, sampled from bayesian optimization. Each palpation includes contour following using a contact-safe impedance controller to trace the sub-dermal tumor geometry, until the underlying tumor-tissue boundary is reached. Projections of these contour following palpation trajectories allows 3D reconstruction of the subdermal tumor surface profile in less than 100 palpations. Our approach generates high-fidelity 3D surface reconstructions of rigid tumor embeddings in tissue layers with isotropic elasticities, although soft tumor geometries are yet to be explored.

Read more

8/27/2024

🤷

Total Score

0

A Passive Variable Impedance Control Strategy with Viscoelastic Parameters Estimation of Soft Tissues for Safe Ultrasonography

Luca Beber (Department of Industrial Engineering, Universit`a di Trento, Trento, Italy), Edoardo Lamon (Department of Information Engineering and Computer Science, Universit`a di Trento, Trento, Italy, Human-Robot Interfaces and Interaction, Istituto Italiano di Tecnologia, Genoa, Italy), Davide Nardi (Department of Information Engineering and Computer Science, Universit`a di Trento, Trento, Italy), Daniele Fontanelli (Department of Industrial Engineering, Universit`a di Trento, Trento, Italy), Matteo Saveriano (Department of Industrial Engineering, Universit`a di Trento, Trento, Italy), Luigi Palopoli (Department of Information Engineering and Computer Science, Universit`a di Trento, Trento, Italy)

In the context of telehealth, robotic approaches have proven a valuable solution to in-person visits in remote areas, with decreased costs for patients and infection risks. In particular, in ultrasonography, robots have the potential to reproduce the skills required to acquire high-quality images while reducing the sonographer's physical efforts. In this paper, we address the control of the interaction of the probe with the patient's body, a critical aspect of ensuring safe and effective ultrasonography. We introduce a novel approach based on variable impedance control, allowing real-time optimisation of a compliant controller parameters during ultrasound procedures. This optimisation is formulated as a quadratic programming problem and incorporates physical constraints derived from viscoelastic parameter estimations. Safety and passivity constraints, including an energy tank, are also integrated to minimise potential risks during human-robot interaction. The proposed method's efficacy is demonstrated through experiments on a patient dummy torso, highlighting its potential for achieving safe behaviour and accurate force control during ultrasound procedures, even in cases of contact loss.

Read more

4/16/2024

Enhancing Precision in Tactile Internet-Enabled Remote Robotic Surgery: Kalman Filter Approach
Total Score

0

Enhancing Precision in Tactile Internet-Enabled Remote Robotic Surgery: Kalman Filter Approach

Muhammad Hanif Lashari, Wafa Batayneh, Ashfaq Khokhar

Accurately estimating the position of a patient's side robotic arm in real time in a remote surgery task is a significant challenge, particularly in Tactile Internet (TI) environments. This paper presents a Kalman Filter (KF) based computationally efficient position estimation method. The study also assume no prior knowledge of the dynamic system model of the robotic arm system. Instead, The JIGSAW dataset, which is a comprehensive collection of robotic surgical data, and the Master Tool Manipulator's (MTM) input are utilized to learn the system model using System Identification (SI) toolkit available in Matlab. We further investigate the effectiveness of KF to determine the position of the Patient Side Manipulator (PSM) under simulated network conditions that include delays, jitter, and packet loss. These conditions reflect the typical challenges encountered in real-world Tactile Internet applications. The results of the study highlight KF's resilience and effectiveness in achieving accurate state estimation despite network-induced uncertainties with over 90% estimation accuracy.

Read more

6/10/2024