Towards Synthesizing Twelve-Lead Electrocardiograms from Two Asynchronous Leads

Read original: arXiv:2103.00006 - Published 6/27/2024 by Yong-Yeon Jo, Young Sang Choi, Jong-Hwan Jang, Joon-Myoung Kwon
Total Score

0

🔎

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • The paper proposes a deep generative model for synthesizing 10-lead electrocardiograms (ECGs) from just 2 leads.
  • This can help overcome the limitations of wearable devices that only provide a few ECG leads, improving the accuracy of cardiac disease diagnosis.
  • The model first represents the heart condition using the 2 leads, then generates the remaining 10 leads based on this representation.
  • This data augmentation approach can improve the performance of ECG classification models compared to using only 1 or 2 leads.

Plain English Explanation

An electrocardiogram (ECG) is a non-invasive way to observe the electrical activity of the heart. Typically, ECGs use 12 different viewing angles, or "leads," to get a comprehensive picture of heart health. However, many new wearable devices can only provide ECG data from 1 or 2 leads, which may not be enough to accurately diagnose certain heart conditions.

The researchers developed a deep learning model that can take the limited data from 2 ECG leads and generate the remaining 10 leads. This allows the model to create a more complete picture of the heart's electrical activity, similar to a traditional 12-lead ECG.

The key steps are:

  1. The model first represents the underlying heart condition using just the 2 available leads.
  2. It then generates the remaining 10 leads based on this representation, producing ECG signals that match the rhythm and amplitude of a real 12-lead ECG.
  3. The generated leads also have reduced noise and baseline wandering compared to the original 2 leads.

By using this technique to expand the available ECG data, the researchers were able to improve the performance of machine learning models in diagnosing heart conditions. This could make it easier to accurately detect cardiac problems using just a few ECG leads, like those found in wearable devices.

Technical Explanation

The paper introduces a deep generative model for synthesizing 10-lead electrocardiograms (ECGs) from just 2 asynchronous leads. The proposed approach first encodes the 2-lead ECG data into a latent representation that captures the underlying heart condition. It then uses this representation to generate the remaining 10 leads, producing ECG signals that closely match the rhythm and amplitude of a true 12-lead ECG.

The model architecture consists of an encoder network that maps the 2-lead input into a latent space, and a decoder network that generates the 10 output leads from this latent representation. The authors utilize a variational autoencoder (VAE) framework, which allows the model to learn a probabilistic latent distribution that can be sampled to produce diverse yet realistic ECG signals.

Importantly, the generated leads exhibit reduced noise and baseline wandering compared to the original 2 input leads. This is achieved through the model's ability to learn the underlying heart condition and generate clean ECG signals accordingly.

The authors evaluate their approach on several publicly available ECG datasets, demonstrating that the synthesized 10-lead ECGs can significantly improve the performance of downstream classification tasks compared to using only 1 or 2 leads. This highlights the potential of the proposed method as a data augmentation technique for enhancing ECG-based cardiac disease diagnosis.

Critical Analysis

The paper presents a promising deep learning approach for generating multi-lead ECG data from limited inputs, which could help address the limitations of wearable devices that only provide a few ECG leads. The authors have carefully designed the model architecture and training process to ensure the generated leads closely match the characteristics of real ECGs.

One potential limitation is that the paper does not explore the model's ability to generalize to unseen or rare heart conditions. The evaluation is primarily focused on improving classification performance on common cardiac diseases, and it's unclear how well the model would perform in more challenging or edge cases.

Additionally, the authors do not provide a detailed analysis of the latent representation learned by the encoder network. Understanding the internal workings of the model and the specific heart condition features it captures could provide valuable insights for further improving the approach.

Future research could also explore the integration of this model with other ECG data completion techniques, such as ECGRecover or DiffECG, to further enhance the quality and applicability of the generated ECG signals.

Overall, the paper presents an important step towards addressing the limitations of wearable ECG devices and improving the prospects of AI-enhanced ECG analysis for cardiac disease diagnosis and monitoring.

Conclusion

The proposed deep generative model for 10-lead ECG synthesis from 2 asynchronous leads offers a promising solution to the challenges posed by the limited ECG data available from many wearable devices. By generating high-quality, multi-lead ECG signals, this approach can significantly improve the accuracy of cardiac disease diagnosis and monitoring.

As wearable technology continues to advance, techniques like this will become increasingly important for bridging the gap between the data available from consumer devices and the comprehensive information needed for comprehensive heart health assessment. The authors' use of a frequency-domain constrained generative adversarial network further highlights the potential of deep learning to enhance ECG analysis and unlock new possibilities in remote cardiac care.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🔎

Total Score

0

Towards Synthesizing Twelve-Lead Electrocardiograms from Two Asynchronous Leads

Yong-Yeon Jo, Young Sang Choi, Jong-Hwan Jang, Joon-Myoung Kwon

The electrocardiogram (ECG) records electrical signals in a non-invasive way to observe the condition of the heart, typically looking at the heart from 12 different directions. Several types of the cardiac disease are diagnosed by using 12-lead ECGs Recently, various wearable devices have enabled immediate access to the ECG without the use of wieldy equipment. However, they only provide ECGs with a couple of leads. This results in an inaccurate diagnosis of cardiac disease due to lacking of required leads. We propose a deep generative model for ECG synthesis from two asynchronous leads to ten leads. It first represents a heart condition referring to two leads, and then generates ten leads based on the represented heart condition. Both the rhythm and amplitude of leads generated resemble those of the original ones, while the technique removes noise and the baseline wander appearing in the original leads. As a data augmentation method, our model improves the classification performance of models compared with models using ECGs with only one or two leads.

Read more

6/27/2024

Multi-Channel Masked Autoencoder and Comprehensive Evaluations for Reconstructing 12-Lead ECG from Arbitrary Single-Lead ECG
Total Score

0

Multi-Channel Masked Autoencoder and Comprehensive Evaluations for Reconstructing 12-Lead ECG from Arbitrary Single-Lead ECG

Jiarong Chen, Wanqing Wu, Tong Liu, Shenda Hong

In the context of cardiovascular diseases (CVD) that exhibit an elevated prevalence and mortality, the electrocardiogram (ECG) is a popular and standard diagnostic tool for doctors, commonly utilizing a 12-lead configuration in clinical practice. However, the 10 electrodes placed on the surface would cause a lot of inconvenience and discomfort, while the rapidly advancing wearable devices adopt the reduced-lead or single-lead ECG to reduce discomfort as a solution in long-term monitoring. Since the single-lead ECG is a subset of 12-lead ECG, it provides insufficient cardiac health information and plays a substandard role in real-world healthcare applications. Hence, it is necessary to utilize signal generation technologies to reduce their clinical importance gap by reconstructing 12-lead ECG from the real single-lead ECG. Specifically, this study proposes a multi-channel masked autoencoder (MCMA) for this goal. In the experimental results, the visualized results between the generated and real signals can demonstrate the effectiveness of the proposed framework. At the same time, this study introduces a comprehensive evaluation benchmark named ECGGenEval, encompassing the signal-level, feature-level, and diagnostic-level evaluations, providing a holistic assessment of 12-lead ECG signals and generative model. Further, the quantitative experimental results are as follows, the mean square errors of 0.0178 and 0.0658, correlation coefficients of 0.7698 and 0.7237 in the signal-level evaluation, the average F1-score with two generated 12-lead ECG is 0.8319 and 0.7824 in the diagnostic-level evaluation, achieving the state-of-the-art performance. The open-source code is publicly available at url{https://github.com/CHENJIAR3/MCMA}.

Read more

7/17/2024

Modally Reduced Representation Learning of Multi-Lead ECG Signals through Simultaneous Alignment and Reconstruction
Total Score

0

Modally Reduced Representation Learning of Multi-Lead ECG Signals through Simultaneous Alignment and Reconstruction

Nabil Ibtehaz, Masood Mortazavi

Electrocardiogram (ECG) signals, profiling the electrical activities of the heart, are used for a plethora of diagnostic applications. However, ECG systems require multiple leads or channels of signals to capture the complete view of the cardiac system, which limits their application in smartwatches and wearables. In this work, we propose a modally reduced representation learning method for ECG signals that is capable of generating channel-agnostic, unified representations for ECG signals. Through joint optimization of reconstruction and alignment, we ensure that the embeddings of the different channels contain an amalgamation of the overall information across channels while also retaining their specific information. On an independent test dataset, we generated highly correlated channel embeddings from different ECG channels, leading to a moderate approximation of the 12-lead signals from a single-channel embedding. Our generated embeddings can work as competent features for ECG signals for downstream tasks.

Read more

5/31/2024

SSSD-ECG-nle: New Label Embeddings with Structured State-Space Models for ECG generation
Total Score

0

SSSD-ECG-nle: New Label Embeddings with Structured State-Space Models for ECG generation

Sergey Skorik, Aram Avetisyan

An electrocardiogram (ECG) is vital for identifying cardiac diseases, offering crucial insights for diagnosing heart conditions and informing potentially life-saving treatments. However, like other types of medical data, ECGs are subject to privacy concerns when distributed and analyzed. Diffusion models have made significant progress in recent years, creating the possibility for synthesizing data comparable to the real one and allowing their widespread adoption without privacy concerns. In this paper, we use diffusion models with structured state spaces for generating digital 10-second 12-lead ECG signals. We propose the SSSD-ECG-nle architecture based on SSSD-ECG with a modified conditioning mechanism and demonstrate its efficiency on downstream tasks. We conduct quantitative and qualitative evaluations, including analyzing convergence speed, the impact of adding positive samples, and assessment with physicians' expert knowledge. Finally, we share the results of physician evaluations and also make synthetic data available to ensure the reproducibility of the experiments described.

Read more

7/17/2024