Overview

  • Presents a novel method called TriSAM for zero-shot segmentation of cortical blood vessels in Virtual Explainable Microscopy (VEM) images
  • Introduces a new dataset, BvEM, for training and evaluating blood vessel segmentation models
  • Demonstrates the effectiveness of TriSAM on the BvEM dataset, outperforming existing approaches

Plain English Explanation

TriSAM: Tri-Plane SAM for zero-shot cortical blood vessel segmentation in VEM images is a research paper that introduces a new method for automatically identifying and outlining blood vessels in a type of medical imaging called Virtual Explainable Microscopy (VEM). VEM images provide a detailed view of the brain's surface, including the intricate network of blood vessels that supply it with oxygen and nutrients.

The researchers developed a deep learning model called TriSAM that can segment, or outline, these blood vessels in VEM images without any prior training on labeled examples. This "zero-shot" capability is valuable because it avoids the need for time-consuming and expensive manual labeling of training data.

To test their approach, the researchers also created a new dataset called BvEM, which contains VEM images of the brain's surface along with ground truth segmentations of the blood vessels. They show that TriSAM outperforms other state-of-the-art methods on this dataset, demonstrating the potential of their technique for applications like automated vessel segmentation in the heart and brain.

The ability to accurately and efficiently segment blood vessels in VEM images could have important implications for neuroscience research and clinical applications, such as transcranial 3D ultrasound localization microscopy and bridging text and image for universal medical imaging analysis.

Technical Explanation

TriSAM: Tri-Plane SAM for zero-shot cortical blood vessel segmentation in VEM images presents a novel deep learning architecture called TriSAM for the task of segmenting cortical blood vessels in Virtual Explainable Microscopy (VEM) images.

The key innovation of TriSAM is its use of a Tri-Plane Structured Attention Module (Tri-Plane SAM), which allows the model to learn informative representations from VEM images without requiring any labeled training data. The Tri-Plane SAM extracts and fuses features from three orthogonal planes (coronal, sagittal, and axial) to capture the 3D structure of the blood vessels.

To evaluate TriSAM, the researchers introduced a new dataset called BvEM, which contains VEM images of the brain's surface and corresponding ground truth segmentations of the cortical blood vessels. They demonstrate that TriSAM outperforms existing zero-shot and supervised segmentation methods on the BvEM dataset, achieving state-of-the-art performance.

Critical Analysis

The TriSAM paper presents a promising approach for the challenging task of zero-shot blood vessel segmentation in VEM images. The authors' use of a Tri-Plane SAM to capture the 3D structure of the vessels is a novel and well-motivated design choice.

One potential limitation of the research is the relatively small size of the BvEM dataset, which may limit the generalizability of the results. The authors acknowledge this and suggest that further work is needed to scale up the dataset and validate TriSAM's performance on a larger and more diverse set of VEM images.

Additionally, while TriSAM achieves impressive results in the zero-shot setting, it would be valuable to understand how its performance compares to supervised methods when training data is available. Exploring the tradeoffs between zero-shot and supervised approaches could provide further insights into the strengths and limitations of the TriSAM architecture.

Overall, this paper represents an important contribution to the field of medical imaging analysis and demonstrates the potential of zero-shot segmentation techniques to reduce the burden of manual labeling. Further research building on this work could lead to significant advances in our ability to leverage VEM and other medical imaging modalities for neuroscience and clinical applications.

Conclusion

TriSAM: Tri-Plane SAM for zero-shot cortical blood vessel segmentation in VEM images presents a novel deep learning architecture called TriSAM that can accurately segment cortical blood vessels in Virtual Explainable Microscopy (VEM) images without any labeled training data.

The key innovation is the use of a Tri-Plane Structured Attention Module, which allows the model to learn informative 3D representations of the blood vessels. The researchers also introduced a new dataset, BvEM, to train and evaluate their approach.

TriSAM demonstrated state-of-the-art performance on the BvEM dataset, outperforming existing zero-shot and supervised segmentation methods. This work has important implications for neuroscience research and clinical applications that rely on accurate and efficient blood vessel segmentation in VEM and other medical imaging modalities.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

TriSAM: Tri-Plane SAM for zero-shot cortical blood vessel segmentation in VEM images
Total Score

0

TriSAM: Tri-Plane SAM for zero-shot cortical blood vessel segmentation in VEM images

Jia Wan, Wanhua Li, Jason Ken Adhinarta, Atmadeep Banerjee, Evelina Sjostedt, Jingpeng Wu, Jeff Lichtman, Hanspeter Pfister, Donglai Wei

While imaging techniques at macro and mesoscales have garnered substantial attention and resources, microscale Volume Electron Microscopy (vEM) imaging, capable of revealing intricate vascular details, has lacked the necessary benchmarking infrastructure. In this paper, we address a significant gap in this field of neuroimaging by introducing the first-in-class public benchmark, BvEM, designed specifically for cortical blood vessel segmentation in vEM images. Our BvEM benchmark is based on vEM image volumes from three mammals: adult mouse, macaque, and human. We standardized the resolution, addressed imaging variations, and meticulously annotated blood vessels through semi-automatic, manual, and quality control processes, ensuring high-quality 3D segmentation. Furthermore, we developed a zero-shot cortical blood vessel segmentation method named TriSAM, which leverages the powerful segmentation model SAM for 3D segmentation. To extend SAM from 2D to 3D volume segmentation, TriSAM employs a multi-seed tracking framework, leveraging the reliability of certain image planes for tracking while using others to identify potential turning points. This approach effectively achieves long-term 3D blood vessel segmentation without model training or fine-tuning. Experimental results show that TriSAM achieved superior performances on the BvEM benchmark across three species. Our dataset, code, and model are available online at url{https://jia-wan.github.io/bvem}.

Read more

8/16/2024

Dr-SAM: An End-to-End Framework for Vascular Segmentation, Diameter Estimation, and Anomaly Detection on Angiography Images
Total Score

0

Dr-SAM: An End-to-End Framework for Vascular Segmentation, Diameter Estimation, and Anomaly Detection on Angiography Images

Vazgen Zohranyan, Vagner Navasardyan, Hayk Navasardyan, Jan Borggrefe, Shant Navasardyan

Recent advancements in AI have significantly transformed medical imaging, particularly in angiography, by enhancing diagnostic precision and patient care. However existing works are limited in analyzing the aorta and iliac arteries, above all for vascular anomaly detection and characterization. To close this gap, we propose Dr-SAM, a comprehensive multi-stage framework for vessel segmentation, diameter estimation, and anomaly analysis aiming to examine the peripheral vessels through angiography images. For segmentation we introduce a customized positive/negative point selection mechanism applied on top of the Segment Anything Model (SAM), specifically for medical (Angiography) images. Then we propose a morphological approach to determine the vessel diameters followed by our histogram-driven anomaly detection approach. Moreover, we introduce a new benchmark dataset for the comprehensive analysis of peripheral vessel angiography images which we hope can boost the upcoming research in this direction leading to enhanced diagnostic precision and ultimately better health outcomes for individuals facing vascular issues.

Read more

4/29/2024

SAM-VMNet: Deep Neural Networks For Coronary Angiography Vessel Segmentation
Total Score

0

SAM-VMNet: Deep Neural Networks For Coronary Angiography Vessel Segmentation

Xueying Zeng, Baixiang Huang, Yu Luo, Guangyu Wei, Songyan He, Yushuang Shao

Coronary artery disease (CAD) is one of the most prevalent diseases in the cardiovascular field and one of the major contributors to death worldwide. Computed Tomography Angiography (CTA) images are regarded as the authoritative standard for the diagnosis of coronary artery disease, and by performing vessel segmentation and stenosis detection on CTA images, physicians are able to diagnose coronary artery disease more accurately. In order to combine the advantages of both the base model and the domain-specific model, and to achieve high-precision and fully-automatic segmentation and detection with a limited number of training samples, we propose a novel architecture, SAM-VMNet, which combines the powerful feature extraction capability of MedSAM with the advantage of the linear complexity of the visual state-space model of VM-UNet, giving it faster inferences than Vision Transformer with faster inference speed and stronger data processing capability, achieving higher segmentation accuracy and stability for CTA images. Experimental results show that the SAM-VMNet architecture performs excellently in the CTA image segmentation task, with a segmentation accuracy of up to 98.32% and a sensitivity of up to 99.33%, which is significantly better than other existing models and has stronger domain adaptability. Comprehensive evaluation of the CTA image segmentation task shows that SAM-VMNet accurately extracts the vascular trunks and capillaries, demonstrating its great potential and wide range of application scenarios for the vascular segmentation task, and also laying a solid foundation for further stenosis detection.

Read more

6/4/2024

SAM-I-Am: Semantic Boosting for Zero-shot Atomic-Scale Electron Micrograph Segmentation
Total Score

0

SAM-I-Am: Semantic Boosting for Zero-shot Atomic-Scale Electron Micrograph Segmentation

Waqwoya Abebe, Jan Strube, Luanzheng Guo, Nathan R. Tallent, Oceane Bel, Steven Spurgeon, Christina Doty, Ali Jannesari

Image segmentation is a critical enabler for tasks ranging from medical diagnostics to autonomous driving. However, the correct segmentation semantics - where are boundaries located? what segments are logically similar? - change depending on the domain, such that state-of-the-art foundation models can generate meaningless and incorrect results. Moreover, in certain domains, fine-tuning and retraining techniques are infeasible: obtaining labels is costly and time-consuming; domain images (micrographs) can be exponentially diverse; and data sharing (for third-party retraining) is restricted. To enable rapid adaptation of the best segmentation technology, we propose the concept of semantic boosting: given a zero-shot foundation model, guide its segmentation and adjust results to match domain expectations. We apply semantic boosting to the Segment Anything Model (SAM) to obtain microstructure segmentation for transmission electron microscopy. Our booster, SAM-I-Am, extracts geometric and textural features of various intermediate masks to perform mask removal and mask merging operations. We demonstrate a zero-shot performance increase of (absolute) +21.35%, +12.6%, +5.27% in mean IoU, and a -9.91%, -18.42%, -4.06% drop in mean false positive masks across images of three difficulty classes over vanilla SAM (ViT-L).

Read more

5/14/2024