Vision Calorimeter for Anti-neutron Reconstruction: A Baseline

Read original: arXiv:2408.10599 - Published 8/21/2024 by Hongtian Yu, Yangu Li, Mingrui Wu, Letian Shen, Yue Liu, Yunxuan Song, Qixiang Ye, Xiaorui Lyu, Yajun Mao, Yangheng Zheng and 1 other
Total Score

0

Vision Calorimeter for Anti-neutron Reconstruction: A Baseline

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents a baseline method for reconstructing anti-neutrons using a vision calorimeter.
  • The researchers aim to address the challenge of accurately detecting and reconstructing anti-neutrons, which is crucial for particle physics experiments.
  • They propose a novel approach that leverages the capabilities of vision calorimetry, which uses high-granularity imaging detectors to capture the shower patterns of particles.

Plain English Explanation

The paper describes a new way to detect and reconstruct anti-neutrons, which are particles that are the opposite of neutrons. Detecting anti-neutrons is important for certain physics experiments, but it can be challenging.

The researchers suggest using a "vision calorimeter" - a type of detector that uses high-resolution imaging to capture the patterns of energy deposits left by particles as they interact with the detector material. By analyzing these patterns, the researchers believe they can more accurately identify and reconstruct anti-neutrons compared to traditional methods.

The paper lays out a "baseline" approach, which means it's a starting point or initial attempt at this new technique. The goal is to establish a foundation that can be built upon and improved in future research.

Technical Explanation

The paper proposes a vision calorimeter-based approach for reconstructing anti-neutrons. Conventional neutron reconstruction methods often struggle with anti-neutrons due to their unique interactions in the detector. The authors suggest that the high granularity and imaging capabilities of vision calorimeters can provide more detailed information to improve anti-neutron reconstruction.

The key aspects of the proposed method include:

  1. Detector Design: The vision calorimeter is designed with high-granularity imaging sensors to capture the detailed shower patterns of particles.
  2. Reconstruction Algorithm: The researchers develop a reconstruction algorithm that can analyze the shower images to identify the characteristics of anti-neutrons and distinguish them from other particle types.
  3. Simulation and Validation: The method is evaluated using Monte Carlo simulations to assess its performance in detecting and reconstructing anti-neutrons.

The paper establishes this vision calorimeter-based approach as a baseline for future work on improving anti-neutron reconstruction, which is crucial for advancing particle physics experiments.

Critical Analysis

The paper provides a solid baseline for using vision calorimetry to reconstruct anti-neutrons, but it also acknowledges several limitations and areas for further research:

  1. Experimental Validation: The method is evaluated using simulations, but the authors note the importance of validating the approach with real experimental data to understand its performance in practical settings.
  2. Computational Complexity: The high-granularity imaging and sophisticated reconstruction algorithm may introduce computational challenges, which the authors suggest could be addressed through efficient neural network architectures.
  3. Robustness to Detector Effects: The paper does not extensively discuss the sensitivity of the method to realistic detector effects, such as noise, non-uniformities, and environmental factors, which could impact its performance in real-world applications.

Overall, the paper presents a promising baseline, but further research is needed to address these practical concerns and refine the vision calorimeter-based anti-neutron reconstruction approach.

Conclusion

This paper introduces a novel baseline method for reconstructing anti-neutrons using a vision calorimeter. The proposed approach leverages the high-granularity imaging capabilities of these detectors to capture detailed shower patterns and improve the identification and reconstruction of anti-neutrons.

The baseline established in this work provides a solid foundation for future research to build upon, potentially leading to more accurate and robust anti-neutron reconstruction techniques. Successful development of such methods could have significant implications for advancing particle physics experiments and our understanding of fundamental particles and their interactions.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Vision Calorimeter for Anti-neutron Reconstruction: A Baseline
Total Score

0

Vision Calorimeter for Anti-neutron Reconstruction: A Baseline

Hongtian Yu, Yangu Li, Mingrui Wu, Letian Shen, Yue Liu, Yunxuan Song, Qixiang Ye, Xiaorui Lyu, Yajun Mao, Yangheng Zheng, Yunfan Liu

In high-energy physics, anti-neutrons ($bar{n}$) are fundamental particles that frequently appear as final-state particles, and the reconstruction of their kinematic properties provides an important probe for understanding the governing principles. However, this confronts significant challenges instrumentally with the electromagnetic calorimeter (EMC), a typical experimental sensor but recovering the information of incident $bar{n}$ insufficiently. In this study, we introduce Vision Calorimeter (ViC), a baseline method for anti-neutron reconstruction that leverages deep learning detectors to analyze the implicit relationships between EMC responses and incident $bar{n}$ characteristics. Our motivation lies in that energy distributions of $bar{n}$ samples deposited in the EMC cell arrays embody rich contextual information. Converted to 2-D images, such contextual energy distributions can be used to predict the status of $bar{n}$ ($i.e.$, incident position and momentum) through a deep learning detector along with pseudo bounding boxes and a specified training objective. Experimental results demonstrate that ViC substantially outperforms the conventional reconstruction approach, reducing the prediction error of incident position by 42.81% (from 17.31$^{circ}$ to 9.90$^{circ}$). More importantly, this study for the first time realizes the measurement of incident $bar{n}$ momentum, underscoring the potential of deep learning detectors for particle reconstruction. Code is available at https://github.com/yuhongtian17/ViC.

Read more

8/21/2024

Interpretable machine learning approach for electron antineutrino selection in a large liquid scintillator detector
Total Score

0

Interpretable machine learning approach for electron antineutrino selection in a large liquid scintillator detector

A. Gavrikov, V. Cerrone, A. Serafini, R. Brugnera, A. Garfagnini, M. Grassi, B. Jelmini, L. Lastrucci, S. Aiello, G. Andronico, V. Antonelli, A. Barresi, D. Basilico, M. Beretta, A. Bergnoli, M. Borghesi, A. Brigatti, R. Bruno, A. Budano, B. Caccianiga, A. Cammi, R. Caruso, D. Chiesa, C. Clementi, S. Dusini, A. Fabbri, G. Felici, F. Ferraro, M. G. Giammarchi, N. Giugice, R. M. Guizzetti, N. Guardone, C. Landini, I. Lippi, S. Loffredo, L. Loi, P. Lombardi, C. Lombardo, F. Mantovani, S. M. Mari, A. Martini, L. Miramonti, M. Montuschi, M. Nastasi, D. Orestano, F. Ortica, A. Paoloni, E. Percalli, F. Petrucci, E. Previtali, G. Ranucci, A. C. Re, M. Redchuck, B. Ricci, A. Romani, P. Saggese, G. Sava, C. Sirignano, M. Sisti, L. Stanco, E. Stanescu Farilla, V. Strati, M. D. C. Torri, A. Triossi, C. Tuv'e, C. Venettacci, G. Verde, L. Votano

Several neutrino detectors, KamLAND, Daya Bay, Double Chooz, RENO, and the forthcoming large-scale JUNO, rely on liquid scintillator to detect reactor antineutrino interactions. In this context, inverse beta decay represents the golden channel for antineutrino detection, providing a pair of correlated events, thus a strong experimental signature to distinguish the signal from a variety of backgrounds. However, given the low cross-section of antineutrino interactions, the development of a powerful event selection algorithm becomes imperative to achieve effective discrimination between signal and backgrounds. In this study, we introduce a machine learning (ML) model to achieve this goal: a fully connected neural network as a powerful signal-background discriminator for a large liquid scintillator detector. We demonstrate, using the JUNO detector as an example, that, despite the already high efficiency of a cut-based approach, the presented ML model can further improve the overall event selection efficiency. Moreover, it allows for the retention of signal events at the detector edges that would otherwise be rejected because of the overwhelming amount of background events in that region. We also present the first interpretable analysis of the ML approach for event selection in reactor neutrino experiments. This method provides insights into the decision-making process of the model and offers valuable information for improving and updating traditional event selection approaches.

Read more

6/21/2024

Autoencoder-based Anomaly Detection System for Online Data Quality Monitoring of the CMS Electromagnetic Calorimeter
Total Score

0

Autoencoder-based Anomaly Detection System for Online Data Quality Monitoring of the CMS Electromagnetic Calorimeter

The CMS ECAL Collaboration

The CMS detector is a general-purpose apparatus that detects high-energy collisions produced at the LHC. Online Data Quality Monitoring of the CMS electromagnetic calorimeter is a vital operational tool that allows detector experts to quickly identify, localize, and diagnose a broad range of detector issues that could affect the quality of physics data. A real-time autoencoder-based anomaly detection system using semi-supervised machine learning is presented enabling the detection of anomalies in the CMS electromagnetic calorimeter data. A novel method is introduced which maximizes the anomaly detection performance by exploiting the time-dependent evolution of anomalies as well as spatial variations in the detector response. The autoencoder-based system is able to efficiently detect anomalies, while maintaining a very low false discovery rate. The performance of the system is validated with anomalies found in 2018 and 2022 LHC collision data. Additionally, the first results from deploying the autoencoder-based system in the CMS online Data Quality Monitoring workflow during the beginning of Run 3 of the LHC are presented, showing its ability to detect issues missed by the existing system.

Read more

6/27/2024

📈

Total Score

0

Calo-VQ: Vector-Quantized Two-Stage Generative Model in Calorimeter Simulation

Qibin Liu, Chase Shimmin, Xiulong Liu, Eli Shlizerman, Shu Li, Shih-Chieh Hsu

We introduce a novel machine learning method developed for the fast simulation of calorimeter detector response, adapting vector-quantized variational autoencoder (VQ-VAE). Our model adopts a two-stage generation strategy: initially compressing geometry-aware calorimeter data into a discrete latent space, followed by the application of a sequence model to learn and generate the latent tokens. Extensive experimentation on the Calo-challenge dataset underscores the efficiency of our approach, showcasing a remarkable improvement in the generation speed compared with conventional method by a factor of 2000. Remarkably, our model achieves the generation of calorimeter showers within milliseconds. Furthermore, comprehensive quantitative evaluations across various metrics are performed to validate physics performance of generation.

Read more

8/7/2024