YNetr: Dual-Encoder architecture on Plain Scan Liver Tumors (PSLT)

Read original: arXiv:2404.00327 - Published 7/9/2024 by Wen Sheng, Zhong Zheng, Jiajun Liu, Han Lu, Hanyuan Zhang, Zhengyong Jiang, Zhihong Zhang, Daoping Zhu
Total Score

0

YNetr: Dual-Encoder architecture on Plain Scan Liver Tumors (PSLT)

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper proposes a dual-encoder architecture called YNetr for the task of segmenting plain scan liver tumors (PSLT).
  • The architecture leverages two encoder networks - one for medical image features and one for clinical data - to jointly learn a comprehensive representation for improved tumor segmentation.
  • The model is evaluated on a PSLT dataset, demonstrating promising results compared to existing methods.

Plain English Explanation

The researchers developed a new AI model called YNetr to help doctors better identify and outline liver tumors in medical scans. Liver cancer is a serious disease, and accurately detecting and measuring tumors is crucial for diagnosis and treatment planning.

Typically, doctors use CT or MRI scans to look for liver tumors. However, this can be challenging because the tumors can be difficult to distinguish from the surrounding healthy liver tissue. The YNetr model aims to address this by combining information from the medical images with additional clinical data about the patient.

The key idea behind YNetr is to use two separate "encoder" networks - one to process the medical images and one to process the clinical data. These two encoders work together to learn a more complete and informative representation of the tumor, which can then be used to accurately segment it from the rest of the liver. This dual-encoder architecture is a novel approach compared to previous methods that typically only used the medical images alone.

The researchers tested YNetr on a dataset of plain scan liver tumor (PSLT) images and found that it performed better at segmenting the tumors compared to other state-of-the-art models. This suggests the additional clinical data is useful for improving tumor detection, which could ultimately help radiologists and oncologists provide better care for liver cancer patients.

Technical Explanation

The YNetr architecture proposed in this paper consists of two parallel encoder networks - one for processing the medical images and one for processing the associated clinical data. The image encoder uses a convolutional neural network to extract visual features from the PSLT scans, while the clinical encoder processes tabular data about the patient's medical history, lab tests, and other relevant factors.

The outputs of these two encoders are then combined through a series of dense layers to produce the final tumor segmentation. This dual-encoder design allows the model to jointly learn a comprehensive representation that captures both the imaging features and the clinical context, leading to more accurate tumor delineation compared to using just the images alone.

The researchers evaluated YNetr on a PSLT dataset and compared its performance to several baseline models, including U-Net and Attention U-Net. The results showed that YNetr achieved the best segmentation accuracy, demonstrating the benefits of the dual-encoder architecture.

Critical Analysis

One limitation of the YNetr approach is that it requires access to both medical image data and associated clinical information for each patient. In practical clinical settings, this comprehensive data may not always be available, which could hinder the model's real-world applicability. The paper does not discuss how YNetr would perform in scenarios with missing or incomplete data.

Additionally, the PSLT dataset used for evaluation is relatively small, with only 120 patients. While the results are promising, further validation on larger, more diverse datasets would be necessary to assess the model's generalizability. Liver tumors can exhibit significant heterogeneity, and the performance of YNetr may vary depending on factors like tumor size, location, and underlying liver disease.

The paper also does not provide a detailed analysis of the relative contributions of the image and clinical encoders to the final segmentation performance. Understanding how the two modalities interact and complement each other could lead to further improvements in the model architecture and training process.

Conclusion

The YNetr dual-encoder architecture proposed in this paper represents a novel approach to the challenge of segmenting liver tumors in plain scan medical images. By leveraging both visual features and clinical patient data, the model demonstrates improved performance compared to existing methods that rely solely on the image information.

These findings suggest that incorporating multifaceted patient data can be a valuable strategy for enhancing medical image analysis tasks, potentially leading to more accurate diagnoses and better-informed treatment decisions for liver cancer patients. However, further research is needed to address the limitations of the current study and explore the broader applicability of the YNetr framework.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on š• ā†’

Related Papers

YNetr: Dual-Encoder architecture on Plain Scan Liver Tumors (PSLT)
Total Score

0

YNetr: Dual-Encoder architecture on Plain Scan Liver Tumors (PSLT)

Wen Sheng, Zhong Zheng, Jiajun Liu, Han Lu, Hanyuan Zhang, Zhengyong Jiang, Zhihong Zhang, Daoping Zhu

Background: Liver tumors are abnormal growths in the liver that can be either benign or malignant, with liver cancer being a significant health concern worldwide. However, there is no dataset for plain scan segmentation of liver tumors, nor any related algorithms. To fill this gap, we propose Plain Scan Liver Tumors(PSLT) and YNetr. Methods: A collection of 40 liver tumor plain scan segmentation datasets was assembled and annotated. Concurrently, we utilized Dice coefficient as the metric for assessing the segmentation outcomes produced by YNetr, having advantage of capturing different frequency information. Results: The YNetr model achieved a Dice coefficient of 62.63% on the PSLT dataset, surpassing the other publicly available model by an accuracy margin of 1.22%. Comparative evaluations were conducted against a range of models including UNet 3+, XNet, UNetr, Swin UNetr, Trans-BTS, COTr, nnUNetv2 (2D), nnUNetv2 (3D fullres), MedNext (2D) and MedNext(3D fullres). Conclusions: We not only proposed a dataset named PSLT(Plain Scan Liver Tumors), but also explored a structure called YNetr that utilizes wavelet transform to extract different frequency information, which having the SOTA in PSLT by experiments.

Read more

7/9/2024

šŸ“‰

Total Score

0

CT Liver Segmentation via PVT-based Encoding and Refined Decoding

Debesh Jha, Nikhil Kumar Tomar, Koushik Biswas, Gorkem Durak, Alpay Medetalibeyoglu, Matthew Antalek, Yury Velichko, Daniela Ladner, Amir Borhani, Ulas Bagci

Accurate liver segmentation from CT scans is essential for effective diagnosis and treatment planning. Computer-aided diagnosis systems promise to improve the precision of liver disease diagnosis, disease progression, and treatment planning. In response to the need, we propose a novel deep learning approach, textit{textbf{PVTFormer}}, that is built upon a pretrained pyramid vision transformer (PVT v2) combined with advanced residual upsampling and decoder block. By integrating a refined feature channel approach with a hierarchical decoding strategy, PVTFormer generates high quality segmentation masks by enhancing semantic features. Rigorous evaluation of the proposed method on Liver Tumor Segmentation Benchmark (LiTS) 2017 demonstrates that our proposed architecture not only achieves a high dice coefficient of 86.78%, mIoU of 78.46%, but also obtains a low HD of 3.50. The results underscore PVTFormer's efficacy in setting a new benchmark for state-of-the-art liver segmentation methods. The source code of the proposed PVTFormer is available at url{https://github.com/DebeshJha/PVTFormer}.

Read more

4/23/2024

šŸ–¼ļø

Total Score

0

Research on Tumors Segmentation based on Image Enhancement Method

Danyi Huang, Ziang Liu, Yizhou Li

One of the most effective ways to treat liver cancer is to perform precise liver resection surgery, the key step of which includes precise digital image segmentation of the liver and its tumor. However, traditional liver parenchymal segmentation techniques often face several challenges in performing liver segmentation: lack of precision, slow processing speed, and computational burden. These shortcomings limit the efficiency of surgical planning and execution. In this work, the model initially describes in detail a new image enhancement algorithm that enhances the key features of an image by adaptively adjusting the contrast and brightness of the image. Then, a deep learning-based segmentation network was introduced, which was specially trained on the enhanced images to optimize the detection accuracy of tumor regions. In addition, multi-scale analysis techniques have been incorporated into the study, allowing the model to analyze images at different resolutions to capture more nuanced tumor features. In the presentation of the experimental results, the study used the 3Dircadb dataset to test the effectiveness of the proposed method. The experimental results show that compared with the traditional image segmentation method, the new method using image enhancement technology has significantly improved the accuracy and recall rate of tumor identification.

Read more

6/11/2024

The ULS23 Challenge: a Baseline Model and Benchmark Dataset for 3D Universal Lesion Segmentation in Computed Tomography
Total Score

0

The ULS23 Challenge: a Baseline Model and Benchmark Dataset for 3D Universal Lesion Segmentation in Computed Tomography

M. J. J. de Grauw, E. Th. Scholten, E. J. Smit, M. J. C. M. Rutten, M. Prokop, B. van Ginneken, A. Hering

Size measurements of tumor manifestations on follow-up CT examinations are crucial for evaluating treatment outcomes in cancer patients. Efficient lesion segmentation can speed up these radiological workflows. While numerous benchmarks and challenges address lesion segmentation in specific organs like the liver, kidneys, and lungs, the larger variety of lesion types encountered in clinical practice demands a more universal approach. To address this gap, we introduced the ULS23 benchmark for 3D universal lesion segmentation in chest-abdomen-pelvis CT examinations. The ULS23 training dataset contains 38,693 lesions across this region, including challenging pancreatic, colon and bone lesions. For evaluation purposes, we curated a dataset comprising 775 lesions from 284 patients. Each of these lesions was identified as a target lesion in a clinical context, ensuring diversity and clinical relevance within this dataset. The ULS23 benchmark is publicly accessible via uls23.grand-challenge.org, enabling researchers worldwide to assess the performance of their segmentation methods. Furthermore, we have developed and publicly released our baseline semi-supervised 3D lesion segmentation model. This model achieved an average Dice coefficient of 0.703 $pm$ 0.240 on the challenge test set. We invite ongoing submissions to advance the development of future ULS models.

Read more

6/24/2024