Adaptive local boundary conditions to improve Deformable Image Registration

Read original: arXiv:2405.12791 - Published 5/22/2024 by Eloise Inacio, Luc Lafitte, Laurent Facq, Clair Poignard, Baudouin Denis de Senneville
Total Score

0

🖼️

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Medical imaging is crucial for image-guided therapy, but movement during imaging can cause misalignment
  • Deformable image registration (DIR) is used to align a moving image with a fixed one, but the boundary conditions used are critical to preventing misalignment
  • This research proposes a novel, automatically-determined boundary condition method to improve DIR performance

Plain English Explanation

In medical treatments that use medical imaging, such as X-rays or CT scans, it's important to be able to accurately assess and correct any movement that occurs during the imaging process. Deformable image registration is a technique used to align a moving image, like a patient's body, with a fixed reference image. However, the way the edges or boundaries of the images are treated can have a big impact on how well the alignment works.

This research introduces a new, automatically-adjustable way to handle the image boundaries during the registration process. The method is designed to flexibly balance between two common boundary condition approaches - one that fixes the edges, and one that allows the edges to move freely. By adapting the boundary conditions on a case-by-case basis, the researchers were able to improve the accuracy of the image registration in two different medical imaging scenarios: aligning chest CT scans and aligning abdominal CT scans with MRI scans.

The key innovation here is the ability to customize the boundary conditions without needing to make any prior assumptions about the images or the motion being registered. This allows the registration process to be optimized for the specific task at hand, leading to better overall results.

Technical Explanation

The researchers propose a "locally adaptive, Robin-type" boundary condition that can balance between the fixed Dirichlet and free-moving Neumann conditions depending on the flow of image data at the boundaries. This generic framework is fully automated, with a reduced set of hyperparameters that are optimized through an energy minimization process.

The proposed method was tested on two medical imaging registration tasks: aligning chest CT scans, and aligning abdominal CT scans with MRI scans. For the chest CT registration, the new approach showed a 4% average improvement in target registration error compared to using homogeneous Dirichlet or Neumann conditions. For the abdominal CT-to-MRI task, the automated framework provided results close to the best achievable.

Critical Analysis

The key strength of this research is the introduction of a flexible, data-driven way to set the boundary conditions for deformable image registration. By adapting the boundary treatment on a case-by-case basis, the method can be tailored to the specific registration problem at hand, potentially yielding better alignment results than a one-size-fits-all approach.

That said, the paper does not provide a detailed analysis of the limitations or failure cases of the proposed framework. It would be valuable to understand how robust the method is to factors like image quality, anatomy, or large deformations. Additionally, while the results are promising, further validation on a wider range of medical imaging scenarios would help establish the generalizability of the approach.

Overall, this research represents an interesting step forward in customizing deformable image registration to suit diverse medical applications. The ability to automatically optimize the boundary conditions without making assumptions about the data is a valuable contribution to the field.

Conclusion

This study highlights the importance of carefully considering the boundary conditions when performing deformable image registration for medical imaging applications. The proposed adaptive, locally-determined boundary condition framework provides a way to optimize the registration process for specific tasks, leading to improved alignment accuracy compared to more generic approaches.

While further validation is needed, this research demonstrates the potential benefits of tailoring the registration problem to the task at hand. By automatically adjusting the boundary treatment, the method can help ensure accurate image alignment without the need for manual parameter tuning or making assumptions about the data. This could have significant implications for improving the reliability and effectiveness of image-guided medical treatments.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🖼️

Total Score

0

Adaptive local boundary conditions to improve Deformable Image Registration

Eloise Inacio, Luc Lafitte, Laurent Facq, Clair Poignard, Baudouin Denis de Senneville

Objective: In medical imaging, it is often crucial to accurately assess and correct movement during image-guided therapy. Deformable image registration (DIR) consists in estimating the required spatial transformation to align a moving image with a fixed one. However, it is acknowledged that, boundary conditions applied to the solution are critical in preventing mis-registration. Despite the extensive research on registration techniques, relatively few have addressed the issue of boundary conditions in the context of medical DIR. Our aim is a step towards customizing boundary conditions to suit the diverse registration tasks at hand. Approach: We propose a generic, locally adaptive, Robin-type condition enabling to balance between Dirichlet and Neumann boundary conditions, depending on incoming/outgoing flow fields on the image boundaries. The proposed framework is entirely automatized through the determination of a reduced set of hyperparameters optimized via energy minimization. Main results: The proposed approach was tested on a mono-modal CT thorax registration task and an abdominal CT to MRI registration task. For the first task, we observed a relative improvement in terms of target registration error of up to 12% (mean 4%), compared to homogeneous Dirichlet and homogeneous Neumann. For the second task, the automatic framework provides results closed to the best achievable. Significance: This study underscores the importance of tailoring the registration problem at the image boundaries. In this research, we introduce a novel method to adapt the boundary conditions on a voxel-by-voxel basis, yielding optimized results in two distinct tasks: mono-modal CT thorax registration and abdominal CT to MRI registration. The proposed framework enables optimized boundary conditions in image registration without any a priori assumptions regarding the images or the motion.

Read more

5/22/2024

🖼️

Total Score

0

Continuous sPatial-Temporal Deformable Image Registration (CPT-DIR) for motion modelling in radiotherapy: beyond classic voxel-based methods

Xia Li, Muheng Li, Antony Lomax, Joachim Buhmann, Ye Zhang

Background and purpose: Deformable image registration (DIR) is a crucial tool in radiotherapy for extracting and modelling organ motion. However, when significant changes and sliding boundaries are present, it faces compromised accuracy and uncertainty, determining the subsequential contour propagation and dose accumulation procedures. Materials and methods: We propose an implicit neural representation (INR)-based approach modelling motion continuously in both space and time, named Continues-sPatial-Temporal DIR (CPT-DIR). This method uses a multilayer perception (MLP) network to map 3D coordinate (x,y,z) to its corresponding velocity vector (vx,vy,vz). The displacement vectors (dx,dy,dz) are then calculated by integrating velocity vectors over time. The MLP's parameters can rapidly adapt to new cases without pre-training, enhancing optimisation. The DIR's performance was tested on the DIR-Lab dataset of 10 lung 4DCT cases, using metrics of landmark accuracy (TRE), contour conformity (Dice) and image similarity (MAE). Results: The proposed CPT-DIR can reduce landmark TRE from 2.79mm to 0.99mm, outperforming B-splines' results for all cases. The MAE of the whole-body region improves from 35.46HU to 28.99HU. Furthermore, CPT-DIR surpasses B-splines for accuracy in the sliding boundary region, lowering MAE and increasing Dice coefficients for the ribcage from 65.65HU and 90.41% to 42.04HU and 90.56%, versus 75.40HU and 89.30% without registration. Meanwhile, CPT-DIR offers significant speed advantages, completing in under 15 seconds compared to a few minutes with the conventional B-splines method. Conclusion: Leveraging the continuous representations, the CPT-DIR method significantly enhances registration accuracy, automation and speed, outperforming traditional B-splines in landmark and contour precision, particularly in the challenging areas.

Read more

5/2/2024

Gaussian Representation for Deformable Image Registration
Total Score

0

Gaussian Representation for Deformable Image Registration

Jihe Li, Fabian Zhang, Xia Li, Tianhao Zhang, Ye Zhang, Joachim Buhmann

Deformable image registration (DIR) is a fundamental task in radiotherapy, with existing methods often struggling to balance computational efficiency, registration accuracy, and speed effectively. We introduce a novel DIR approach employing parametric 3D Gaussian control points achieving a better tradeoff. It provides an explicit and flexible representation for spatial deformation fields between 3D volumetric medical images, producing a displacement vector field (DVF) across all volumetric positions. The movement of individual voxels is derived using linear blend skinning (LBS) through localized interpolation of transformations associated with neighboring Gaussians. This interpolation strategy not only simplifies the determination of voxel motions but also acts as an effective regularization technique. Our approach incorporates a unified optimization process through backpropagation, enabling iterative learning of both the parameters of the 3D Gaussians and their transformations. Additionally, the density of Gaussians is adjusted adaptively during the learning phase to accommodate varying degrees of motion complexity. We validated our approach on the 4D-CT lung DIR-Lab and cardiac ACDC datasets, achieving an average target registration error (TRE) of 1.06 mm within a much-improved processing time of 2.43 seconds for the DIR-Lab dataset over existing methods, demonstrating significant advancements in both accuracy and efficiency.

Read more

6/6/2024

🖼️

Total Score

0

Diffeomorphic Transformer-based Abdomen MRI-CT Deformable Image Registration

Yang Lei, Luke A. Matkovic, Justin Roper, Tonghe Wang, Jun Zhou, Beth Ghavidel, Mark McDonald, Pretesh Patel, Xiaofeng Yang

This paper aims to create a deep learning framework that can estimate the deformation vector field (DVF) for directly registering abdominal MRI-CT images. The proposed method assumed a diffeomorphic deformation. By using topology-preserved deformation features extracted from the probabilistic diffeomorphic registration model, abdominal motion can be accurately obtained and utilized for DVF estimation. The model integrated Swin transformers, which have demonstrated superior performance in motion tracking, into the convolutional neural network (CNN) for deformation feature extraction. The model was optimized using a cross-modality image similarity loss and a surface matching loss. To compute the image loss, a modality-independent neighborhood descriptor (MIND) was used between the deformed MRI and CT images. The surface matching loss was determined by measuring the distance between the warped coordinates of the surfaces of contoured structures on the MRI and CT images. The deformed MRI image was assessed against the CT image using the target registration error (TRE), Dice similarity coefficient (DSC), and mean surface distance (MSD) between the deformed contours of the MRI image and manual contours of the CT image. When compared to only rigid registration, DIR with the proposed method resulted in an increase of the mean DSC values of the liver and portal vein from 0.850 and 0.628 to 0.903 and 0.763, a decrease of the mean MSD of the liver from 7.216 mm to 3.232 mm, and a decrease of the TRE from 26.238 mm to 8.492 mm. The proposed deformable image registration method based on a diffeomorphic transformer provides an effective and efficient way to generate an accurate DVF from an MRI-CT image pair of the abdomen. It could be utilized in the current treatment planning workflow for liver radiotherapy.

Read more

5/7/2024