Admittance Control for Adaptive Remote Center of Motion in Robotic Laparoscopic Surgery

Read original: arXiv:2404.04416 - Published 4/9/2024 by Ehsan Nasiri, Long Wang
Total Score

0

Admittance Control for Adaptive Remote Center of Motion in Robotic Laparoscopic Surgery

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents a new admittance control algorithm for adaptive remote center of motion (RCM) in robotic laparoscopic surgery.
  • The proposed approach aims to improve the dexterity and control of surgical instruments during minimally invasive procedures.
  • The authors demonstrate the effectiveness of their method through simulations and experiments on a custom-built robotic platform.

Plain English Explanation

The paper focuses on improving the control of robotic surgical tools used in minimally invasive procedures, such as laparoscopy. In these procedures, the surgical instruments are inserted through small incisions and need to pivot around a fixed point, called the remote center of motion (RCM), to allow for precise manipulation inside the patient's body.

The researchers developed a new control algorithm called "admittance control" to adaptively adjust the RCM based on the surgeon's movements and the task requirements. This allows for more natural and intuitive control of the surgical instruments, potentially enhancing the surgeon's dexterity and precision during the procedure.

The key idea is to treat the RCM as a virtual, compliant joint that can be adjusted in real-time, rather than a rigid constraint. This gives the surgeon more flexibility to maneuver the instruments while maintaining the necessary pivoting motion around the RCM.

The authors evaluated their approach through simulations and experiments on a custom-built robotic platform, demonstrating its effectiveness in improving the control and responsiveness of the surgical instruments.

Technical Explanation

The paper presents an admittance control algorithm for adaptive remote center of motion (RCM) in robotic laparoscopic surgery. The authors develop a kinematic model that treats the RCM as a virtual, compliant joint, allowing for real-time adjustment based on the surgeon's inputs and task requirements.

The control architecture includes an outer admittance control loop that modulates the RCM position and orientation, and an inner position control loop that drives the robotic manipulator to follow the desired motion. This hierarchical structure enables smooth and responsive control of the surgical instruments.

The authors validate their approach through simulations and experiments on a custom-built robotic platform, similar to the one described in their previous work. The results demonstrate improved dexterity and control compared to a traditional, fixed RCM approach.

Critical Analysis

The paper presents a promising approach for enhancing the control of robotic surgical instruments in minimally invasive procedures. The adaptive RCM concept, enabled by the admittance control algorithm, is well-motivated and has the potential to improve surgeon ergonomics and procedural outcomes.

However, the authors acknowledge that the current implementation is limited to simulation and a custom-built platform. Further validation on clinical-grade robotic systems and in realistic surgical scenarios would be necessary to fully assess the practical benefits and limitations of the proposed method.

Additionally, the paper does not address the potential challenges of integrating the adaptive RCM control with existing robotic surgery platforms, which may have their own control architectures and constraints. Addressing these integration issues would be an important next step towards real-world deployment.

Conclusion

This paper presents a novel admittance control algorithm for adaptive remote center of motion (RCM) in robotic laparoscopic surgery. The proposed approach aims to improve the dexterity and control of surgical instruments by treating the RCM as a virtual, compliant joint that can be adjusted in real-time based on the surgeon's inputs and task requirements.

The authors demonstrate the effectiveness of their method through simulations and experiments on a custom-built robotic platform, showing enhanced responsiveness and control compared to a traditional, fixed RCM approach. While further validation on clinical-grade systems and in realistic surgical scenarios is needed, this research represents a promising step towards more intuitive and effective control of robotic surgical tools, which could ultimately lead to improved outcomes for patients undergoing minimally invasive procedures.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Admittance Control for Adaptive Remote Center of Motion in Robotic Laparoscopic Surgery
Total Score

0

Admittance Control for Adaptive Remote Center of Motion in Robotic Laparoscopic Surgery

Ehsan Nasiri, Long Wang

In laparoscopic robot-assisted minimally invasive surgery, the kinematic control of the robot is subject to the remote center of motion (RCM) constraint at the port of entry (e.g., trocar) into the patient's body. During surgery, after the instrument is inserted through the trocar, intrinsic physiological movements such as the patient's heartbeat, breathing process, and/or other purposeful body repositioning may deviate the position of the port of entry. This can cause a conflict between the registered RCM and the moved port of entry. To mitigate this conflict, we seek to utilize the interaction forces at the RCM. We develop a novel framework that integrates admittance control into a redundancy resolution method for the RCM kinematic constraint. Using the force/torque sensory feedback at the base of the instrument driving mechanism (IDM), the proposed framework estimates the forces at RCM, rejects forces applied on other locations along the instrument, and uses them in the admittance controller. In this paper, we report analysis from kinematic simulations to validate the proposed framework. In addition, a hardware platform has been completed, and future work is planned for experimental validation.

Read more

4/9/2024

Teleoperation in Robot-assisted MIS with Adaptive RCM via Admittance Control
Total Score

0

Teleoperation in Robot-assisted MIS with Adaptive RCM via Admittance Control

Ehsan Nasiri, Srikarran Sowrirajan, Long Wang

This paper presents the development and assessment of a teleoperation framework for robot-assisted minimally invasive surgery (MIS). The framework leverages our novel integration of an adaptive remote center of motion (RCM) using admittance control. This framework operates within a redundancy resolution method specifically designed for the RCM constraint. We introduce a compact, low-cost, and modular custom-designed instrument module (IM) that ensures integration with the manipulator, featuring a force-torque sensor, a surgical instrument, and an actuation unit for driving the surgical instrument. The paper details the complete teleoperation framework, including the telemanipulation trajectory mapping, kinematic modelling, control strategy, and the integrated admittance controller. Finally, the system capability to perform various surgical tasks was demonstrated, including passing a thread through the rings, picking and placing objects, and trajectory tracking.

Read more

7/18/2024

RCM-Constrained Manipulator Trajectory Tracking Using Differential Kinematics Control
Total Score

0

RCM-Constrained Manipulator Trajectory Tracking Using Differential Kinematics Control

Omar Rayyan, Vinicius Gonc{c}alves, Nikolaos Evangeliou, Anthony Tzes

This paper proposes an approach for controlling surgical robotic systems, while complying with the Remote Center of Motion (RCM) constraint in Robot-Assisted Minimally Invasive Surgery (RA-MIS). In this approach, the RCM-constraint is upheld algorithmically, providing flexibility in the positioning of the insertion point and enabling compatibility with a wide range of general-purpose robots. The paper further investigates the impact of the tool's insertion ratio on the RCM-error, and introduces a manipulability index of the robot which considers the RCM-error that it is used to find a starting configuration. To accurately evaluate the proposed method's trajectory tracking within an RCM-constrained environment, an electromagnetic tracking system is employed. The results demonstrate the effectiveness of the proposed method in addressing the RCM constraint problem in RA-MIS.

Read more

9/10/2024

🎯

Total Score

0

The control architecture of a spherical robot for Minimally Invasive Surgery

Gabriela Rus (UMP), Nadim Al Hajjar (UMP), Paul Tucan (UMP), Ionut Zima (UMP), Calin Vaida (UMP), Corina Radu (UMP), Daniel Jucan (LS2N, LS2N - 'equipe RoMas), Damien Chablat (LS2N, LS2N - 'equipe RoMas), Doina Pisla

Control systems used in Minimally Invasive Surgery (MIS) play a crucial role in ensuring preci-sion and safety throughout procedures. This paper presents a control architecture developed for a robotic system designed for MIS operations. The modular structure of the control system allows for compatibility with a range of procedures in abdominal and thoracic regions. The proposed control system, employing the master-slave concept, is presented alongside the experimental model. Functional validation is obtained by performing a Siemens NX simulation and comparing the results with several experimental runs using the experimental model of the robot. With its compact size and stiffness, the system holds promise for integration with other robotic systems. Future efforts will be dedicated to exploring and optimizing this potential collaboration to enhance the overall capabilities of robotic-assisted surgery.

Read more

7/12/2024