  • This paper presents a control system developed for a robotic system designed for Minimally Invasive Surgery (MIS) procedures.
  • The modular control system is designed to be compatible with a range of abdominal and thoracic MIS procedures.
  • The proposed control system uses a master-slave concept and is validated through simulation and experimental testing.
  • The system's compact size and stiffness make it promising for integration with other robotic systems for enhanced robotic-assisted surgery capabilities.

Plain English Explanation

During Minimally Invasive Surgery (MIS) procedures, precise control of the surgical tools is crucial for ensuring safety and efficiency. This paper describes a new control system that was developed for a robotic system designed specifically for MIS operations.

The control system has a modular design, which means it can be adapted to work with a variety of different MIS procedures, including those in the abdomen and chest regions. The control system uses a "master-slave" concept, where the surgeon controls a "master" device, and the robotic system then precisely mimics those movements on the "slave" device inside the patient's body.

The researchers tested this new control system through computer simulations and by building a physical model of the robotic system. The simulation and real-world tests showed that the control system works as intended, providing precise control of the robotic tools. The compact size and stiffness of the system also suggest it could be easily integrated with other robotic systems to enhance the overall capabilities of robot-assisted surgery.

Technical Explanation

The paper presents a modular control architecture developed for a robotic system designed for Minimally Invasive Surgery (MIS) procedures. The control system employs a master-slave concept, where the surgeon's inputs on a "master" device are precisely replicated by the "slave" robotic system inside the patient's body.

The researchers validated the functionality of the proposed control system through two main approaches:

  1. Siemens NX simulation: The researchers performed a detailed simulation of the robotic system's movements and control to verify its performance.

  2. Experimental model: The researchers also built a physical prototype of the robotic system and conducted several experimental runs to compare the results with the simulation.

The results from both the simulation and physical experiments demonstrated the efficacy of the proposed control system in precisely controlling the robotic tools for MIS procedures. The compact size and high stiffness of the system suggest it could be easily integrated with other robotic systems to enhance the overall capabilities of robot-assisted surgery.

Critical Analysis

The paper provides a thorough evaluation of the proposed control system for the MIS robotic system, including both simulation and physical testing. However, the paper does not delve deeply into any potential limitations or challenges that may arise during real-world clinical implementation.

For example, the paper does not address how the control system would handle unexpected movements or disturbances during an actual surgical procedure. Additionally, the paper does not discuss the potential impact of the system's size and integration with other robotic platforms on factors like accessibility, ease of use, or overall surgical workflow.

Further research would be needed to fully understand the practical implications and limitations of this control system in a clinical setting. Exploring the integration of this system with other robotic platforms, such as endoscope holders, could also provide valuable insights into its broader applicability and potential for enhancing robotic-assisted surgery.

Conclusion

This paper presents a modular control system developed for a robotic platform designed for Minimally Invasive Surgery (MIS) procedures. The control system uses a master-slave concept to provide precise control of the robotic tools, and its performance has been validated through both simulation and physical experimentation.

The compact size and high stiffness of the system suggest it could be easily integrated with other robotic systems, potentially enhancing the overall capabilities of robot-assisted surgery. While the paper provides a thorough technical evaluation of the control system, further research would be needed to fully understand its practical implications and limitations in a real-world clinical setting.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🎯

Total Score

0

The control architecture of a spherical robot for Minimally Invasive Surgery

Gabriela Rus (UMP), Nadim Al Hajjar (UMP), Paul Tucan (UMP), Ionut Zima (UMP), Calin Vaida (UMP), Corina Radu (UMP), Daniel Jucan (LS2N, LS2N - 'equipe RoMas), Damien Chablat (LS2N, LS2N - 'equipe RoMas), Doina Pisla

Control systems used in Minimally Invasive Surgery (MIS) play a crucial role in ensuring preci-sion and safety throughout procedures. This paper presents a control architecture developed for a robotic system designed for MIS operations. The modular structure of the control system allows for compatibility with a range of procedures in abdominal and thoracic regions. The proposed control system, employing the master-slave concept, is presented alongside the experimental model. Functional validation is obtained by performing a Siemens NX simulation and comparing the results with several experimental runs using the experimental model of the robot. With its compact size and stiffness, the system holds promise for integration with other robotic systems. Future efforts will be dedicated to exploring and optimizing this potential collaboration to enhance the overall capabilities of robotic-assisted surgery.

Read more

7/12/2024

Teleoperation in Robot-assisted MIS with Adaptive RCM via Admittance Control
Total Score

0

Teleoperation in Robot-assisted MIS with Adaptive RCM via Admittance Control

Ehsan Nasiri, Srikarran Sowrirajan, Long Wang

This paper presents the development and assessment of a teleoperation framework for robot-assisted minimally invasive surgery (MIS). The framework leverages our novel integration of an adaptive remote center of motion (RCM) using admittance control. This framework operates within a redundancy resolution method specifically designed for the RCM constraint. We introduce a compact, low-cost, and modular custom-designed instrument module (IM) that ensures integration with the manipulator, featuring a force-torque sensor, a surgical instrument, and an actuation unit for driving the surgical instrument. The paper details the complete teleoperation framework, including the telemanipulation trajectory mapping, kinematic modelling, control strategy, and the integrated admittance controller. Finally, the system capability to perform various surgical tasks was demonstrated, including passing a thread through the rings, picking and placing objects, and trajectory tracking.

Read more

7/18/2024

📉

Total Score

0

A Low-Cost Teleoperable Surgical Robot with a Macro-Micro Structure and a Continuum Tip for Open-Source Research

Lachlan Scott, Tangyou Liu, Liao Wu

Surgical robotic systems equipped with microscale, high-dexterity manipulators have shown promising results in minimally invasive surgery (MIS). One barrier to the widespread adoption of such systems is the prohibitive cost of research and development efforts using current state-of-the-art equipment. To address this challenge, this paper proposes a low-cost and modifiable tendon-driven continuum manipulator for MIS applications. The device is capable of being teleoperated in conjunction with a macro-scale six-axis robotic arm using a haptic stylus. Its control software incorporates and extends freely available and open-source software packages. For verification, we perform teleoperation trials on the proposed continuum manipulator using an electromagnetic tracker. We then integrate the manipulator with a UR5e robotic arm. A series of simulated tumour biopsies were conducted using the integrated robotic system and an anatomical model (phantom), validating its potential efficacy in MIS applications. The complete source code, CAD files for all additively manufactured components, a parts list for the manipulator, and a demonstration video of the proposed system are made available in this work.

Read more

5/28/2024

A Master-Follower Teleoperation System for Robotic Catheterization: Design, Characterization, and Tracking Control
Total Score

0

A Master-Follower Teleoperation System for Robotic Catheterization: Design, Characterization, and Tracking Control

Ali A. Nazari, Jeremy Catania, Soroush Sadeghian, Amir Jalali, Houman Masnavi, Farrokh Janabi-Sharifi, Kourosh Zareinia

Minimally invasive robotic surgery has gained significant attention over the past two decades. Telerobotic systems, combined with robot-mediated minimally invasive techniques, have enabled surgeons and clinicians to mitigate radiation exposure for medical staff and extend medical services to remote and hard-to-reach areas. To enhance these services, teleoperated robotic surgery systems incorporating master and follower devices should offer transparency, enabling surgeons and clinicians to remotely experience a force interaction similar to the one the follower device experiences with patients' bodies. This paper presents the design and development of a three-degree-of-freedom master-follower teleoperated system for robotic catheterization. To resemble manual intervention by clinicians, the follower device features a grip-insert-release mechanism to eliminate catheter buckling and torsion during operation. The bidirectionally navigable ablation catheter is statically characterized for force-interactive medical interventions. The system's performance is evaluated through approaching and open-loop path tracking over typical circular, infinity-like, and spiral paths. Path tracking errors are presented as mean Euclidean error (MEE) and mean absolute error (MAE). The MEE ranges from 0.64 cm (infinity-like path) to 1.53 cm (spiral path). The MAE also ranges from 0.81 cm (infinity-like path) to 1.92 cm (spiral path). The results indicate that while the system's precision and accuracy with an open-loop controller meet the design targets, closed-loop controllers are necessary to address the catheter's hysteresis and dead zone, and system nonlinearities.

Read more

7/19/2024