  • Existing entropy-based studies on electrocardiogram (ECG) signals have not fully utilized the variability in amplitude and phase patterns caused by cardiac activity and individual differences.
  • The paper proposes a novel fusion entropy metric called Morphological ECG Entropy (MEE) to comprehensively describe the fusion of amplitude and phase patterns in ECG signals.
  • MEE is designed specifically for ECG morphology and computed based on beat-level samples, enabling detailed analysis of each cardiac cycle.

Plain English Explanation

The paper introduces a new way to analyze electrocardiogram (ECG) signals, which measure the electrical activity of the heart. ECG signals can vary a lot in their amplitude (strength) and phase (timing) patterns, both due to the heart's activity and differences between individuals.

Previous studies using entropy-based techniques have not fully captured this variability. To address this, the researchers developed a new metric called Morphological ECG Entropy (MEE) that can comprehensively describe the amplitude and phase patterns in ECG signals.

MEE is specially designed to work with the unique shape, or "morphology," of ECG signals. It is calculated using individual heartbeat samples, allowing for a detailed analysis of each cardiac cycle. This enables rapid and accurate detection of abnormal heart rhythms (arrhythmias) without needing labeled data.

Additionally, MEE can be used to assess the diversity of ECG samples, which can help compress imbalanced training datasets by selecting the most representative samples. MEE also has the ability to identify areas of poor ECG signal quality.

The researchers demonstrated that MEE is robust to noise interference and has low computational complexity, making it suitable for clinical use. They have also integrated MEE into an interactive interface to provide a more user-friendly experience for healthcare professionals.

Technical Explanation

The paper proposes a novel fusion entropy metric called Morphological ECG Entropy (MEE) to comprehensively describe the amplitude and phase patterns in electrocardiogram (ECG) signals. Unlike previous entropy-based approaches that have not fully utilized these two key patterns, MEE is specifically designed for ECG morphology and computed based on beat-level samples.

The researchers conducted experiments to demonstrate that MEE can rapidly and accurately localize abnormal ECG arrhythmia regions in a label-free manner. Furthermore, MEE provides a method for assessing sample diversity, enabling the compression of imbalanced training sets through representative sample selection, outperforming random pruning techniques.

MEE also exhibits the ability to describe areas of poor ECG signal quality. The paper discusses the robustness of MEE value calculation to noise interference and its low computational complexity, making it suitable for clinical applications. Finally, the researchers have integrated the MEE method into a clinical interactive interface to enhance the user experience for healthcare professionals.

Critical Analysis

The paper presents a novel and promising approach to ECG signal analysis through the MEE metric. However, some potential limitations and areas for further research are worth considering:

The paper does not provide a detailed evaluation of MEE's performance compared to other state-of-the-art ECG analysis techniques, which would be helpful in assessing its relative strengths and weaknesses. Additionally, the paper does not explore the impact of different ECG signal preprocessing techniques on the MEE calculation, which could be an important consideration.

While the researchers claim MEE is robust to noise interference, the paper does not provide a comprehensive analysis of its performance under various noise conditions or signal-to-noise ratios. Further investigation in this area could strengthen the claims about MEE's suitability for real-world clinical applications.

Finally, the clinical interactive interface mentioned in the paper is not described in detail, and the user experience evaluation is limited. More thorough user testing and feedback could help refine the interface and ensure it meets the needs of healthcare professionals.

Conclusion

The proposed Morphological ECG Entropy (MEE) metric represents a novel and potentially valuable approach to comprehensively analyzing the amplitude and phase patterns in electrocardiogram (ECG) signals. MEE's ability to rapidly and accurately localize abnormal ECG arrhythmia regions, assess sample diversity, and identify areas of poor signal quality could have significant implications for ECG-based clinical diagnosis and training data management.

The paper's findings suggest that MEE could serve as a robust and computationally efficient clinical descriptor for ECG characterization, with the potential to be integrated into interactive tools for healthcare professionals. Further research and evaluation, particularly in the areas of noise resilience and user experience, could help solidify MEE's place as a valuable addition to the ECG analysis toolkit.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🎯

Total Score

0

Amplitude-Phase Fusion for Enhanced Electrocardiogram Morphological Analysis

Shuaicong Hu, Yanan Wang, Jian Liu, Jingyu Lin, Shengmei Qin, Zhenning Nie, Zhifeng Yao, Wenjie Cai, Cuiwei Yang

Considering the variability of amplitude and phase patterns in electrocardiogram (ECG) signals due to cardiac activity and individual differences, existing entropy-based studies have not fully utilized these two patterns and lack integration. To address this gap, this paper proposes a novel fusion entropy metric, morphological ECG entropy (MEE) for the first time, specifically designed for ECG morphology, to comprehensively describe the fusion of amplitude and phase patterns. MEE is computed based on beat-level samples, enabling detailed analysis of each cardiac cycle. Experimental results demonstrate that MEE achieves rapid, accurate, and label-free localization of abnormal ECG arrhythmia regions. Furthermore, MEE provides a method for assessing sample diversity, facilitating compression of imbalanced training sets (via representative sample selection), and outperforms random pruning. Additionally, MEE exhibits the ability to describe areas of poor quality. By discussing, it proves the robustness of MEE value calculation to noise interference and its low computational complexity. Finally, we integrate this method into a clinical interactive interface to provide a more convenient and intuitive user experience. These findings indicate that MEE serves as a valuable clinical descriptor for ECG characterization. The implementation code can be referenced at the following link: https://github.com/fdu-harry/ECG-MEE-metric.

Read more

4/16/2024

MEIT: Multi-Modal Electrocardiogram Instruction Tuning on Large Language Models for Report Generation
Total Score

0

MEIT: Multi-Modal Electrocardiogram Instruction Tuning on Large Language Models for Report Generation

Zhongwei Wan, Che Liu, Xin Wang, Chaofan Tao, Hui Shen, Zhenwu Peng, Jie Fu, Rossella Arcucci, Huaxiu Yao, Mi Zhang

Electrocardiogram (ECG) is the primary non-invasive diagnostic tool for monitoring cardiac conditions and is crucial in assisting clinicians. Recent studies have concentrated on classifying cardiac conditions using ECG data but have overlooked ECG report generation, which is time-consuming and requires clinical expertise. To automate ECG report generation and ensure its versatility, we propose the Multimodal ECG Instruction Tuning (MEIT) framework, the first attempt to tackle ECG report generation with LLMs and multimodal instructions. To facilitate future research, we establish a benchmark to evaluate MEIT with various LLMs backbones across two large-scale ECG datasets. Our approach uniquely aligns the representations of the ECG signal and the report, and we conduct extensive experiments to benchmark MEIT with nine open-source LLMs using more than 800,000 ECG reports. MEIT's results underscore the superior performance of instruction-tuned LLMs, showcasing their proficiency in quality report generation, zero-shot capabilities, and resilience to signal perturbation. These findings emphasize the efficacy of our MEIT framework and its potential for real-world clinical application.

Read more

6/19/2024

⛏️

Total Score

0

Extraction of Maternal and fetal ECG in a non-invasive way from abdominal ECG recordings using modified Progressive FastICA Peel-off

Yao Li, Xuanyu Luo, Haowen Zhao, Jiawen Cui, Yangfan She, Dongfang Li, Lai Jiang, Xu Zhang

The abdominal electrocardiogram (AECG) gives a safe and non-invasive way to monitor fetal well-being during pregnancy. However, due to the overlap with maternal ECG (MECG) as well as significant external noise, it is challenging to extract weak fetal ECG (FECG) using surface electrodes. In this study, we introduce a novel periodic progressive FastICA peel-off (PPFP) method for noninvasive extraction of weak surface FECG signals, leveraging the two-step FastICA method and a peel-off strategy from the progressive FastICA peel-off (PFP) approach. Specifically, for ECG signals, the periodic constrained FastICA that integrates ECG signal characteristics enables precise extraction of MECG and FECG spike trains. Additionally, a peel-off strategy incorporating SVD waveform reconstruction ensures comprehensive identification of subtle source signals. The performance of the proposed method was examined on public datasets with reference, synthetic data and clinical data, with an F1-scores for FECG extraction on public dataset of 99.59%, on synthetic data with the highest noise level of 99.50%, which are all superior to other comparative methods. Furthermore, clearly periodic and physiologically consistent FECG signals were extracted from clinically collected data. The results indicates that our proposed method has potential and effectiveness to separate MECG and weak FECG from multichannel AECG with high precision in high noise condition, which is of vital importance for ensuring the safety of both the fetus and the mother, as well as the advancement of artificial intelligent clinical monitoring.

Read more

7/23/2024

🏷️

Total Score

0

Enhanced Classification of Heart Sounds Using Mel Frequency Cepstral Coefficients: A Comparative Study of Single and Ensemble Classifier Strategies

Amir Masoud Rahmani, Amir Haider, Mohammad Adeli, Olfa Mzoughi, Entesar Gemeay, Mokhtar Mohammadi, Hamid Alinejad-Rokny, Parisa Khoshvaght, Mehdi Hosseinzadeh

This paper explores the efficacy of Mel Frequency Cepstral Coefficients (MFCCs) in detecting abnormal heart sounds using two classification strategies: a single classifier and an ensemble classifier approach. Heart sounds were first pre-processed to remove noise and then segmented into S1, systole, S2, and diastole intervals, with thirteen MFCCs estimated from each segment, yielding 52 MFCCs per beat. Finally, MFCCs were used for heart sound classification. For that purpose, in the single classifier strategy, the MFCCs from nine consecutive beats were averaged to classify heart sounds by a single classifier (either a support vector machine (SVM), the k nearest neighbors (kNN), or a decision tree (DT)). Conversely, the ensemble classifier strategy employed nine classifiers (either nine SVMs, nine kNN classifiers, or nine DTs) to individually assess beats as normal or abnormal, with the overall classification based on the majority vote. Both methods were tested on a publicly available phonocardiogram database. The heart sound classification accuracy was 91.95% for the SVM, 91.9% for the kNN, and 87.33% for the DT in the single classifier strategy. Also, the accuracy was 93.59% for the SVM, 91.84% for the kNN, and 92.22% for the DT in the ensemble classifier strategy. Overall, the results demonstrated that the ensemble classifier strategy improved the accuracies of the DT and the SVM by 4.89% and 1.64%, establishing MFCCs as more effective than other features, including time, time-frequency, and statistical features, evaluated in similar studies.

Read more