Extraction of Maternal and fetal ECG in a non-invasive way from abdominal ECG recordings using modified Progressive FastICA Peel-off

Read original: arXiv:2406.01281 - Published 7/23/2024 by Yao Li, Xuanyu Luo, Haowen Zhao, Jiawen Cui, Yangfan She, Dongfang Li, Lai Jiang, Xu Zhang
Total Score

0

⛏️

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • The paper presents a novel framework for extracting weak fetal electrocardiogram (FECG) signals from non-invasive abdominal electrocardiogram (AECG) recordings.
  • The framework combines the precise source separation capability of the FastICA approach with a constrained version specific to FECG, the weak source extraction capability of the peel-off strategy, and the FECG waveform reconstruction ability of the singular value decomposition (SVD) method.
  • The framework includes a periodic constrained FastICA (pcFastICA) algorithm to improve the precision of examining and correcting FECG source signals, and a successive judgment algorithm to select the optimal maternal and fetal ECG signals.

Plain English Explanation

Monitoring the health of a fetus during pregnancy is crucial, but it can be challenging to accurately measure the fetal heartbeat using surface electrodes on the mother's abdomen. This is because the fetal signal is often very weak and can be easily obscured by the mother's own heartbeat and other background noise.

The researchers in this paper have developed a new approach to address this problem. They have combined several advanced signal processing techniques to extract the weak fetal signal from the noisy abdominal recordings. The key innovations include the use of the FastICA algorithm, which can separate the different sources of the signal, and the addition of constraints specifically designed for the characteristics of the fetal heartbeat. They also use a technique called the "peel-off strategy" to focus on the weaker fetal signal, and singular value decomposition to reconstruct the fetal waveform.

The researchers tested their framework on several public datasets, as well as synthetic data and real clinical data. They were able to achieve very high accuracy in extracting the fetal heartbeat, with F1-scores (a measure of accuracy) of over 99% in many cases. This represents a significant improvement over other methods and could have important implications for ensuring the safety of both the mother and the fetus during pregnancy.

Technical Explanation

The paper presents a novel framework for extracting weak fetal electrocardiogram (FECG) signals from non-invasive abdominal electrocardiogram (AECG) recordings. The framework leverages the precise source separation capability of the FastICA approach, combined with a constrained version specific to FECG (pcFastICA), the weak source extraction capability of the peel-off strategy, and the FECG waveform reconstruction ability of the singular value decomposition (SVD) method.

The pcFastICA algorithm was developed to improve the precision of examining and correcting FECG source signals, based on the statistical characteristics of continuous and repetitive ECG emissions. Additionally, a successive judgment algorithm was designed to select the optimal maternal and fetal ECG signals.

The performance of the proposed method was evaluated on public datasets, synthetic data, and clinical data. The F1-scores for FECG extraction on the ADFECG and NIFECGA datasets were 99.71% and 99.36%, respectively. On synthetic data with the highest noise level, the F1-score was 98.77%, and on clinical data, the F1-score was 98.09%. These results outperform other comparative methods, indicating the potential and effectiveness of the proposed framework in separating weak FECG from multichannel AECG with high precision in high-noise conditions.

Critical Analysis

The paper presents a comprehensive and well-designed framework for extracting weak fetal ECG signals from noisy abdominal recordings. The researchers have leveraged a range of advanced signal processing techniques, including FastICA, the peel-off strategy, and SVD, to address the challenges of separating the fetal signal from the maternal signal and other noise sources.

One potential limitation of the study is the reliance on public datasets and synthetic data. While the results on these datasets are impressive, it would be valuable to see the framework tested on a larger and more diverse set of clinical data to fully understand its real-world performance and robustness.

Additionally, the paper does not provide a detailed discussion of the computational complexity and processing time of the proposed framework. This information would be useful for assessing the practical implementation of the method, especially in the context of real-time clinical monitoring.

Further research could also explore the potential of combining this FECG extraction framework with other advanced ECG analysis techniques, such as those discussed in the "Amplitude-Phase Fusion Enhanced Electrocardiogram Morphological Analysis" and "Prospects of AI-Enhanced ECG as Unified Screening" papers, to provide a more comprehensive assessment of fetal well-being during pregnancy.

Conclusion

The paper presents a novel framework for extracting weak fetal electrocardiogram (FECG) signals from non-invasive abdominal electrocardiogram (AECG) recordings. The framework combines the strengths of various signal processing techniques, including FastICA, the peel-off strategy, and SVD, to address the challenges of separating the fetal signal from the maternal signal and other noise sources.

The results of the study demonstrate the potential and effectiveness of the proposed method in achieving high-precision FECG extraction, even in high-noise conditions. This is of vital importance for ensuring the safety of both the fetus and the mother during pregnancy, as well as the advancement of artificial intelligence-based clinical monitoring.

While the paper provides a strong foundation, further research is needed to fully assess the real-world performance and practical implementation of the framework, as well as explore its integration with other advanced ECG analysis techniques for a more comprehensive assessment of fetal well-being.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

⛏️

Total Score

0

Extraction of Maternal and fetal ECG in a non-invasive way from abdominal ECG recordings using modified Progressive FastICA Peel-off

Yao Li, Xuanyu Luo, Haowen Zhao, Jiawen Cui, Yangfan She, Dongfang Li, Lai Jiang, Xu Zhang

The abdominal electrocardiogram (AECG) gives a safe and non-invasive way to monitor fetal well-being during pregnancy. However, due to the overlap with maternal ECG (MECG) as well as significant external noise, it is challenging to extract weak fetal ECG (FECG) using surface electrodes. In this study, we introduce a novel periodic progressive FastICA peel-off (PPFP) method for noninvasive extraction of weak surface FECG signals, leveraging the two-step FastICA method and a peel-off strategy from the progressive FastICA peel-off (PFP) approach. Specifically, for ECG signals, the periodic constrained FastICA that integrates ECG signal characteristics enables precise extraction of MECG and FECG spike trains. Additionally, a peel-off strategy incorporating SVD waveform reconstruction ensures comprehensive identification of subtle source signals. The performance of the proposed method was examined on public datasets with reference, synthetic data and clinical data, with an F1-scores for FECG extraction on public dataset of 99.59%, on synthetic data with the highest noise level of 99.50%, which are all superior to other comparative methods. Furthermore, clearly periodic and physiologically consistent FECG signals were extracted from clinically collected data. The results indicates that our proposed method has potential and effectiveness to separate MECG and weak FECG from multichannel AECG with high precision in high noise condition, which is of vital importance for ensuring the safety of both the fetus and the mother, as well as the advancement of artificial intelligent clinical monitoring.

Read more

7/23/2024

⛏️

Total Score

0

Extraction of Weak Surface Diaphragmatic Electromyogram Using Modified Progressive FastICA Peel-Off

Yao Li, Dongsheng Zhao, Haowen Zhao, Xu Zhang, Min Shao

Diaphragmatic electromyogram (EMGdi) contains crucial information about human respiration therefore can be used to monitor respiratory condition. Although it is practical to record EMGdi noninvasively and conveniently by placing surface electrodes over chest skin, extraction of such weak surface EMGdi (sEMGdi) from great noisy environment is a challenging task, limiting its clinical use compared with esophageal EMGdi. In this paper, a novel method is presented for extracting weak sEMGdi signal from high-noise environment based on fast independent component analysis (FastICA), constrained FastICA and a peel-off strategy. It is truly a modified version of of progressive FastICA peel-off (PFP) framework, where the constrained FastICA helps to extract and refine respiration-related sEMGdi signals, while the peel-off strategy ensures the complete extraction of weaker sEMGdi components. The method was validated using both synthetic and clinical signals. It was demonstrated that our method was able to extract clean sEMGdi signals efficiently with little distortion. It outperformed state-of-the-art comparison methods in terms of sufficiently high SIR and CORR at all noise levels when tested on synthetic data, while also achieved an accuracy of 95.06% and a F2-score of 96.73% for breath identification on clinical data. The study presents a valuable solution for noninvasive extraction of sEMGdi signals, providing a convenient and valuable way of ventilator synchrony with a significant potential in aiding respiratory rehabilitation and health.

Read more

7/1/2024

🎯

Total Score

0

Amplitude-Phase Fusion for Enhanced Electrocardiogram Morphological Analysis

Shuaicong Hu, Yanan Wang, Jian Liu, Jingyu Lin, Shengmei Qin, Zhenning Nie, Zhifeng Yao, Wenjie Cai, Cuiwei Yang

Considering the variability of amplitude and phase patterns in electrocardiogram (ECG) signals due to cardiac activity and individual differences, existing entropy-based studies have not fully utilized these two patterns and lack integration. To address this gap, this paper proposes a novel fusion entropy metric, morphological ECG entropy (MEE) for the first time, specifically designed for ECG morphology, to comprehensively describe the fusion of amplitude and phase patterns. MEE is computed based on beat-level samples, enabling detailed analysis of each cardiac cycle. Experimental results demonstrate that MEE achieves rapid, accurate, and label-free localization of abnormal ECG arrhythmia regions. Furthermore, MEE provides a method for assessing sample diversity, facilitating compression of imbalanced training sets (via representative sample selection), and outperforms random pruning. Additionally, MEE exhibits the ability to describe areas of poor quality. By discussing, it proves the robustness of MEE value calculation to noise interference and its low computational complexity. Finally, we integrate this method into a clinical interactive interface to provide a more convenient and intuitive user experience. These findings indicate that MEE serves as a valuable clinical descriptor for ECG characterization. The implementation code can be referenced at the following link: https://github.com/fdu-harry/ECG-MEE-metric.

Read more

4/16/2024

Contactless seismocardiography via Gunnar-Farneback optical flow
Total Score

0

Contactless seismocardiography via Gunnar-Farneback optical flow

Mohammad Muntasir Rahman, Amirtaha Taebi

Seismocardiography (SCG) has gained significant attention due to its potential applications in monitoring cardiac health and diagnosing cardiovascular conditions. Conventional SCG methods rely on accelerometers attached to the chest, which can be uncomfortable or inconvenient. In recent years, researchers have explored non-contact methods to capture SCG signals, and one promising approach involves analyzing video recordings of the chest. In this study, we investigate a vision-based method based on the Gunnar-Farneback optical flow to extract SCG signals from the chest skin movements recorded by a smartphone camera. We compared the SCG signals extracted from the chest videos of four healthy subjects with those obtained from accelerometers and our previous method based on sticker tracking. Our results demonstrated that the vision-based SCG signals extracted by the proposed method closely resembled those from accelerometers and stickers, although these signals were captured from slightly different locations. The mean squared error between the vision-based SCG signals and accelerometer-based signals was found to be within a reasonable range, especially between signals on head-to-foot direction (0.2$<$MSE$<$1.5). Additionally, heart rates derived from the vision-based SCG exhibited good agreement with the gold-standard ECG measurements, with a mean difference of 0.8 bpm. These results indicate the potential of this non-invasive method in health monitoring and diagnostics.

Read more

8/20/2024