Cosserat Rods for Modeling Tendon-Driven Robotic Catheter Systems

Read original: arXiv:2407.07618 - Published 7/11/2024 by Pierre-Frederic Villard, Thomas M. Waite, Robert D. Howe
Total Score

0

🏅

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents a mathematical model for a tendon-driven robotic catheter system.
  • The model uses Cosserat rods to represent both the catheter and a single tendon, and integrates them with a stable, implicit Euler scheme.
  • The model is validated against experimental data and a large deformation analytical model to confirm its physical accuracy.

Plain English Explanation

Robotic catheters are specialized tools used in minimally invasive cardiac procedures like ablations and imaging. These procedures require precisely controlling the movement and interaction of the catheter with the surrounding tissue and blood vessels. To achieve this control, researchers have developed mathematical models that can accurately predict the behavior of the catheter and its attached tendons.

This paper presents a new model that uses Cosserat rods to represent both the catheter itself and a single tendon that controls its movement. Cosserat rods are a way of mathematically describing the shape and deformation of flexible, rod-like structures. By modeling the catheter and tendon as separate Cosserat rods and integrating them together, the researchers were able to create a comprehensive model that could accurately predict the behavior of the entire tendon-catheter system.

The researchers validated their model by comparing its predictions to both a large deformation analytical model and experimental data collected from physical tests. This confirmed that the model was able to accurately capture the real-world behavior of the robotic catheter. This new model represents an important contribution to the field of robotic catheter modeling, where accurately predicting the complex interactions between the catheter, tendons, and surrounding tissue is crucial for precise control during medical procedures.

Technical Explanation

The paper presents a mechanical model of a tendon-driven robotic catheter system based on Cosserat rods. Cosserat rods are a well-established mathematical framework for modeling the shape and deformation of flexible, rod-like structures. In this case, the researchers use one Cosserat rod to represent the catheter centerline and a second Cosserat rod to model a single tendon.

The catheter Cosserat rod model is first validated against a large deformation analytical model and experimental data to confirm its physical accuracy. The tendon is then integrated into the model using penalty forces to define the constraints between the tendon and the catheter. This combined catheter-tendon model is also validated against experimental data.

By using Cosserat rods to model both the catheter and tendon, the researchers were able to create a comprehensive model that captures the complex interactions between the two components. This represents an advancement in the field of robotic catheter modeling, where accurately predicting the behavior of the catheter-tendon system is crucial for precise control during medical procedures.

Critical Analysis

The paper provides a thorough validation of the proposed Cosserat rod model against both analytical and experimental data, which lends confidence to the model's accuracy. However, the validation is limited to a single tendon case, and the researchers acknowledge that extending the model to multiple tendons will require additional work.

Additionally, the model assumes a constant and uniform catheter cross-section, which may not always hold true in real-world scenarios where the catheter may experience variable deformation and stiffness along its length. Incorporating more realistic catheter properties, such as variable stiffness, could help improve the model's fidelity.

Further research is also needed to investigate the model's performance in simulating the complex interactions between the catheter, tendons, and surrounding anatomy during actual medical procedures. Validating the model's predictive capabilities in more realistic in-vivo scenarios would strengthen its practical utility for robotic catheter control and guidance.

Conclusion

This paper presents a new mathematical model for tendon-driven robotic catheters that uses Cosserat rods to accurately represent both the catheter and its controlling tendons. The model is extensively validated against analytical and experimental data, demonstrating its ability to capture the complex mechanics of the catheter-tendon system.

This work represents an important advancement in the field of robotic catheter modeling, which is crucial for enabling the precise control and guidance of these surgical tools during minimally invasive cardiac procedures. By improving our ability to predict the behavior of robotic catheters, this research can contribute to the development of more accurate and effective robotic systems for enhanced patient care.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🏅

Total Score

0

Cosserat Rods for Modeling Tendon-Driven Robotic Catheter Systems

Pierre-Frederic Villard, Thomas M. Waite, Robert D. Howe

Tendon-driven robotic catheters are capable of precise execution of minimally invasive cardiac procedures including ablations and imaging. These procedures require accurate mathematical models of not only the catheter and tendons but also their interactions with surrounding tissue and vasculature in order to control the robot path and interaction. This paper presents a mechanical model of a tendon-driven robotic catheter system based on Cosserat rods and integrated with a stable, implicit Euler scheme. We implement the Cosserat rod as a model for a simple catheter centerline and validate its physical accuracy against a large deformation analytical model and experimental data. The catheter model is then supplemented by adding a second Cosserat rod to model a single tendon, using penalty forces to define the constraints of the tendon-catheter system. All the model parameters are defined by the catheter properties established by the design. The combined model is validated against experimental data to confirm its physical accuracy. This model represents a new contribution to the field of robotic catheter modeling in which both the tendons and catheter are modeled by mechanical Cosserat rods and fully-validated against experimental data in the case of the single rod system.

Read more

7/11/2024

Total Score

0

Cosserat Rod Modeling and Validation for a Soft Continuum Robot with Self-Controllable Variable Curvature

Xinran Wang, Nicolas Rojas

This paper introduces a Cosserat rod based mathematical model for modeling a self-controllable variable curvature soft continuum robot. This soft continuum robot has a hollow inner channel and was developed with the ability to perform variable curvature utilizing a growing spine. The growing spine is able to grow and retract while modifies its stiffness through milli-size particle (glass bubble) granular jamming. This soft continuum robot can then perform continuous curvature variation, unlike previous approaches whose curvature variation is discrete and depends on the number of locking mechanisms or manual configurations. The robot poses an emergent modeling problem due to the variable stiffness growing spine which is addressed in this paper. We investigate the property of growing spine stiffness and incorporate it into the Cosserat rod model by implementing a combined stiffness approach. We conduct experiments with the soft continuum robot in various configurations and compared the results with our developed mathematical model. The results show that the mathematical model based on the adapted Cosserat rod matches the experimental results with only a 3.3% error with respect to the length of the soft continuum robot.

Read more

6/28/2024

A Master-Follower Teleoperation System for Robotic Catheterization: Design, Characterization, and Tracking Control
Total Score

0

A Master-Follower Teleoperation System for Robotic Catheterization: Design, Characterization, and Tracking Control

Ali A. Nazari, Jeremy Catania, Soroush Sadeghian, Amir Jalali, Houman Masnavi, Farrokh Janabi-Sharifi, Kourosh Zareinia

Minimally invasive robotic surgery has gained significant attention over the past two decades. Telerobotic systems, combined with robot-mediated minimally invasive techniques, have enabled surgeons and clinicians to mitigate radiation exposure for medical staff and extend medical services to remote and hard-to-reach areas. To enhance these services, teleoperated robotic surgery systems incorporating master and follower devices should offer transparency, enabling surgeons and clinicians to remotely experience a force interaction similar to the one the follower device experiences with patients' bodies. This paper presents the design and development of a three-degree-of-freedom master-follower teleoperated system for robotic catheterization. To resemble manual intervention by clinicians, the follower device features a grip-insert-release mechanism to eliminate catheter buckling and torsion during operation. The bidirectionally navigable ablation catheter is statically characterized for force-interactive medical interventions. The system's performance is evaluated through approaching and open-loop path tracking over typical circular, infinity-like, and spiral paths. Path tracking errors are presented as mean Euclidean error (MEE) and mean absolute error (MAE). The MEE ranges from 0.64 cm (infinity-like path) to 1.53 cm (spiral path). The MAE also ranges from 0.81 cm (infinity-like path) to 1.92 cm (spiral path). The results indicate that while the system's precision and accuracy with an open-loop controller meet the design targets, closed-loop controllers are necessary to address the catheter's hysteresis and dead zone, and system nonlinearities.

Read more

7/19/2024

Rod models in continuum and soft robot control: a review
Total Score

0

Rod models in continuum and soft robot control: a review

Carlo Alessi, Camilla Agabiti, Daniele Caradonna, Cecilia Laschi, Federico Renda, Egidio Falotico

Continuum and soft robots can positively impact diverse sectors, from biomedical applications to marine and space exploration, thanks to their potential to adaptively interact with unstructured environments. However, the complex mechanics exhibited by these robots pose diverse challenges in modeling and control. Reduced order continuum mechanical models based on rod theories have emerged as a promising framework, striking a balance between accurately capturing deformations of slender bodies and computational efficiency. This review paper explores rod-based models and control strategies for continuum and soft robots. In particular, it summarizes the mathematical background underlying the four main rod theories applied in soft robotics. Then, it categorizes the literature on rod models applied to continuum and soft robots based on deformation classes, actuation technology, or robot type. Finally, it reviews recent model-based and learning-based control strategies leveraging rod models. The comprehensive review includes a critical discussion of the trends, advantages, limits, and possible future developments of rod models. This paper could guide researchers intending to simulate and control new soft robots and provide feedback to the design and manufacturing community.

Read more

7/9/2024