A Master-Follower Teleoperation System for Robotic Catheterization: Design, Characterization, and Tracking Control

Read original: arXiv:2407.13162 - Published 7/19/2024 by Ali A. Nazari, Jeremy Catania, Soroush Sadeghian, Amir Jalali, Houman Masnavi, Farrokh Janabi-Sharifi, Kourosh Zareinia
Total Score

0

A Master-Follower Teleoperation System for Robotic Catheterization: Design, Characterization, and Tracking Control

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents the design, characterization, and tracking control of a master-follower teleoperation system for robotic catheterization.
  • The system consists of a master robot manipulator and a slave robot manipulator, which are used to control a robotic catheter for minimally invasive surgical procedures.

Plain English Explanation

The researchers have developed a robotic system that allows a surgeon to control a small robot inside a patient's body during a medical procedure, such as inserting a catheter. The system has two main parts:

  1. A "master" robot that the surgeon uses to control the movements of the robot inside the patient. The surgeon moves the master robot, and this motion is then replicated by the "slave" robot inside the patient.

  2. The "slave" robot, which is the small robot inside the patient's body that actually performs the medical procedure. It follows the movements of the master robot controlled by the surgeon.

This setup allows the surgeon to precisely control the movements of the robot inside the patient's body, without having to put their hands directly inside the patient. This can make minimally invasive surgical procedures, like inserting a catheter, safer and more accurate. The researchers have carefully designed and tested this teleoperation system to ensure it can accurately track the surgeon's movements and control the robot inside the patient.

Technical Explanation

The researchers developed a master-follower teleoperation system for robotic catheterization. The system consists of a master robot manipulator and a slave robot manipulator, which are used to control a robotic catheter.

The master robot is equipped with force sensors that measure the forces applied by the surgeon. These force measurements are used to control the motion of the slave robot inside the patient's body, allowing the surgeon to teleoperate the slave robot. The researchers characterized the performance of the system and developed a novel tracking control algorithm to ensure accurate positioning of the slave robot.

The proposed low-cost teleoperable surgical robot and teleoperation control scheme allow the surgeon to perform minimally invasive procedures with improved precision and reduced risk to the patient. The system also has the potential to be used for autonomous navigation of catheters and guidewires in medical procedures.

Critical Analysis

The researchers have provided a detailed characterization of the master-follower teleoperation system, including an analysis of the tracking control performance. However, the paper does not discuss any potential limitations or caveats of the system, such as the range of motion or force capabilities of the master and slave robots.

Additionally, the researchers do not compare their system to other teleoperation approaches for robotic catheters, which would help the reader understand the unique contributions and advantages of the proposed system.

Overall, the research seems well-designed and executed, but the paper could benefit from a more thorough discussion of the system's limitations and a comparison to related work in the field.

Conclusion

This paper presents a novel master-follower teleoperation system for robotic catheterization, which allows surgeons to precisely control the movements of a small robot inside a patient's body during minimally invasive medical procedures. The researchers have carefully designed and characterized the system, demonstrating its potential to improve the safety and accuracy of catheter-based interventions.

The proposed system represents an important step forward in the development of advanced robotic tools for minimally invasive surgery. By enabling surgeons to teleoperate a robotic catheter, this technology could lead to better patient outcomes and reduced procedural risks. Further research is needed to explore the system's practical limitations and compare it to other teleoperation approaches in the field.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

A Master-Follower Teleoperation System for Robotic Catheterization: Design, Characterization, and Tracking Control
Total Score

0

A Master-Follower Teleoperation System for Robotic Catheterization: Design, Characterization, and Tracking Control

Ali A. Nazari, Jeremy Catania, Soroush Sadeghian, Amir Jalali, Houman Masnavi, Farrokh Janabi-Sharifi, Kourosh Zareinia

Minimally invasive robotic surgery has gained significant attention over the past two decades. Telerobotic systems, combined with robot-mediated minimally invasive techniques, have enabled surgeons and clinicians to mitigate radiation exposure for medical staff and extend medical services to remote and hard-to-reach areas. To enhance these services, teleoperated robotic surgery systems incorporating master and follower devices should offer transparency, enabling surgeons and clinicians to remotely experience a force interaction similar to the one the follower device experiences with patients' bodies. This paper presents the design and development of a three-degree-of-freedom master-follower teleoperated system for robotic catheterization. To resemble manual intervention by clinicians, the follower device features a grip-insert-release mechanism to eliminate catheter buckling and torsion during operation. The bidirectionally navigable ablation catheter is statically characterized for force-interactive medical interventions. The system's performance is evaluated through approaching and open-loop path tracking over typical circular, infinity-like, and spiral paths. Path tracking errors are presented as mean Euclidean error (MEE) and mean absolute error (MAE). The MEE ranges from 0.64 cm (infinity-like path) to 1.53 cm (spiral path). The MAE also ranges from 0.81 cm (infinity-like path) to 1.92 cm (spiral path). The results indicate that while the system's precision and accuracy with an open-loop controller meet the design targets, closed-loop controllers are necessary to address the catheter's hysteresis and dead zone, and system nonlinearities.

Read more

7/19/2024

🎯

Total Score

0

The control architecture of a spherical robot for Minimally Invasive Surgery

Gabriela Rus (UMP), Nadim Al Hajjar (UMP), Paul Tucan (UMP), Ionut Zima (UMP), Calin Vaida (UMP), Corina Radu (UMP), Daniel Jucan (LS2N, LS2N - 'equipe RoMas), Damien Chablat (LS2N, LS2N - 'equipe RoMas), Doina Pisla

Control systems used in Minimally Invasive Surgery (MIS) play a crucial role in ensuring preci-sion and safety throughout procedures. This paper presents a control architecture developed for a robotic system designed for MIS operations. The modular structure of the control system allows for compatibility with a range of procedures in abdominal and thoracic regions. The proposed control system, employing the master-slave concept, is presented alongside the experimental model. Functional validation is obtained by performing a Siemens NX simulation and comparing the results with several experimental runs using the experimental model of the robot. With its compact size and stiffness, the system holds promise for integration with other robotic systems. Future efforts will be dedicated to exploring and optimizing this potential collaboration to enhance the overall capabilities of robotic-assisted surgery.

Read more

7/12/2024

📉

Total Score

0

A Low-Cost Teleoperable Surgical Robot with a Macro-Micro Structure and a Continuum Tip for Open-Source Research

Lachlan Scott, Tangyou Liu, Liao Wu

Surgical robotic systems equipped with microscale, high-dexterity manipulators have shown promising results in minimally invasive surgery (MIS). One barrier to the widespread adoption of such systems is the prohibitive cost of research and development efforts using current state-of-the-art equipment. To address this challenge, this paper proposes a low-cost and modifiable tendon-driven continuum manipulator for MIS applications. The device is capable of being teleoperated in conjunction with a macro-scale six-axis robotic arm using a haptic stylus. Its control software incorporates and extends freely available and open-source software packages. For verification, we perform teleoperation trials on the proposed continuum manipulator using an electromagnetic tracker. We then integrate the manipulator with a UR5e robotic arm. A series of simulated tumour biopsies were conducted using the integrated robotic system and an anatomical model (phantom), validating its potential efficacy in MIS applications. The complete source code, CAD files for all additively manufactured components, a parts list for the manipulator, and a demonstration video of the proposed system are made available in this work.

Read more

5/28/2024

Teleoperation in Robot-assisted MIS with Adaptive RCM via Admittance Control
Total Score

0

Teleoperation in Robot-assisted MIS with Adaptive RCM via Admittance Control

Ehsan Nasiri, Srikarran Sowrirajan, Long Wang

This paper presents the development and assessment of a teleoperation framework for robot-assisted minimally invasive surgery (MIS). The framework leverages our novel integration of an adaptive remote center of motion (RCM) using admittance control. This framework operates within a redundancy resolution method specifically designed for the RCM constraint. We introduce a compact, low-cost, and modular custom-designed instrument module (IM) that ensures integration with the manipulator, featuring a force-torque sensor, a surgical instrument, and an actuation unit for driving the surgical instrument. The paper details the complete teleoperation framework, including the telemanipulation trajectory mapping, kinematic modelling, control strategy, and the integrated admittance controller. Finally, the system capability to perform various surgical tasks was demonstrated, including passing a thread through the rings, picking and placing objects, and trajectory tracking.

Read more

7/18/2024