Cross-domain Denoising for Low-dose Multi-frame Spiral Computed Tomography

Read original: arXiv:2304.10839 - Published 7/1/2024 by Yucheng Lu, Zhixin Xu, Moon Hyung Choi, Jimin Kim, Seung-Won Jung
Total Score

0

💬

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Computed tomography (CT) scans are widely used for medical diagnosis, but the ionizing radiation involved raises health concerns.
  • Researchers have been working to improve the quality of low-dose CT (LDCT) scans, which use less radiation, by developing better reconstruction techniques.
  • Previous LDCT denoising methods have shown promise, but they were often tested on simulated data that doesn't fully capture the real-world challenges of multi-slice spiral CT scanners.
  • This paper proposes a two-stage method tailored for commercially available multi-slice spiral CT scanners, aiming to better exploit the complete reconstruction pipeline for LDCT denoising.

Plain English Explanation

CT scans are a useful medical tool, but the X-rays used can be harmful if you're exposed to too much radiation. Researchers have been trying to find ways to get high-quality CT images while using less radiation. Some past studies have shown that machine learning-based methods can help "clean up" low-dose CT scans and reduce the noise in the images.

However, most of these studies have only been tested on simulated data, which doesn't fully match the reality of how CT scanners work in the real world. This paper proposes a new two-stage method that's designed specifically for the type of multi-slice spiral CT scanners that are commonly used in hospitals and clinics. The key idea is to make better use of all the different pieces of data that go into reconstructing the final CT image, in order to remove noise without losing important details.

The researchers ran extensive tests on various datasets and found that their method could remove up to 70% of the noise in low-dose CT scans without compromising the spatial resolution (clarity) of the images. Two experienced radiologists also reviewed the results and agreed that this new approach performed better than other state-of-the-art methods in real-world clinical scenarios.

Technical Explanation

The proposed method takes advantage of the high redundancy in the multi-slice projections and volumetric reconstructions of LDCT scans to better denoise the images. It overcomes the over-smoothing problem seen in previous cascaded frameworks, which can occur when aggressive denoising is applied.

The two-stage architecture first uses a neural network to learn a residual mapping between the low-dose and standard-dose CT volumes. This is trained on a large dataset of paired low-dose and standard-dose scans, without relying on simulated data. The second stage then applies a dedicated denoising module that further refines the output of the first stage, leveraging the unique properties of the multi-slice spiral CT data.

Extensive experiments were conducted on various datasets, including clinical data from a commercial CT scanner. The results showed that the proposed method could remove up to 70% of noise from LDCT scans without compromising spatial resolution. Subjective evaluations by two radiologists also confirmed the superior performance of this approach compared to state-of-the-art LDCT denoising methods in real-world clinical practice.

Critical Analysis

The key strength of this research is the tailored design for the multi-slice spiral CT scanner geometry, which better captures the real-world challenges compared to previous studies that relied more on simulated data. By explicitly modeling the complete reconstruction pipeline, the authors were able to develop a more effective denoising solution.

However, the paper does not provide much detail on the specific architectural choices or training procedures used for the neural networks. Additionally, while the results are promising, the authors acknowledge that further research is needed to fully understand the generalization capabilities of the method across different scanner models and clinical scenarios.

Future work could explore ways to make the method more robust and adaptable, perhaps by incorporating techniques like partitioned Hankel-based diffusion models for few-shot learning or multi-view X-ray image synthesis. Comparisons to other state-of-the-art approaches, such as CT image denoising using residual encoder-decoder networks or dual-domain unfolding for CT reconstruction, could also provide additional insights.

Conclusion

This paper presents a promising two-stage method for denoising low-dose CT scans that is specifically designed for the multi-slice spiral scanner geometry commonly used in clinical practice. By better exploiting the complete reconstruction pipeline, the authors were able to achieve significant noise reduction without compromising spatial resolution. The positive evaluations from experienced radiologists suggest this approach could have a meaningful impact in real-world medical imaging applications, helping to reduce radiation exposure while maintaining diagnostic quality.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

💬

Total Score

0

Cross-domain Denoising for Low-dose Multi-frame Spiral Computed Tomography

Yucheng Lu, Zhixin Xu, Moon Hyung Choi, Jimin Kim, Seung-Won Jung

Computed tomography (CT) has been used worldwide as a non-invasive test to assist in diagnosis. However, the ionizing nature of X-ray exposure raises concerns about potential health risks such as cancer. The desire for lower radiation doses has driven researchers to improve reconstruction quality. Although previous studies on low-dose computed tomography (LDCT) denoising have demonstrated the effectiveness of learning-based methods, most were developed on the simulated data. However, the real-world scenario differs significantly from the simulation domain, especially when using the multi-slice spiral scanner geometry. This paper proposes a two-stage method for the commercially available multi-slice spiral CT scanners that better exploits the complete reconstruction pipeline for LDCT denoising across different domains. Our approach makes good use of the high redundancy of multi-slice projections and the volumetric reconstructions while leveraging the over-smoothing problem in conventional cascaded frameworks caused by aggressive denoising. The dedicated design also provides a more explicit interpretation of the data flow. Extensive experiments on various datasets showed that the proposed method could remove up to 70% of noise without compromised spatial resolution, and subjective evaluations by two experienced radiologists further supported its superior performance against state-of-the-art methods in clinical practice.

Read more

7/1/2024

Learned denoising with simulated and experimental low-dose CT data
Total Score

0

Learned denoising with simulated and experimental low-dose CT data

Maximilian B. Kiss, Ander Biguri, Carola-Bibiane Schonlieb, K. Joost Batenburg, Felix Lucka

Like in many other research fields, recent developments in computational imaging have focused on developing machine learning (ML) approaches to tackle its main challenges. To improve the performance of computational imaging algorithms, machine learning methods are used for image processing tasks such as noise reduction. Generally, these ML methods heavily rely on the availability of high-quality data on which they are trained. This work explores the application of ML methods, specifically convolutional neural networks (CNNs), in the context of noise reduction for computed tomography (CT) imaging. We utilize a large 2D computed tomography dataset for machine learning to carry out for the first time a comprehensive study on the differences between the observed performances of algorithms trained on simulated noisy data and on real-world experimental noisy data. The study compares the performance of two common CNN architectures, U-Net and MSD-Net, that are trained and evaluated on both simulated and experimental noisy data. The results show that while sinogram denoising performed better with simulated noisy data if evaluated in the sinogram domain, the performance did not carry over to the reconstruction domain where training on experimental noisy data shows a higher performance in denoising experimental noisy data. Training the algorithms in an end-to-end fashion from sinogram to reconstruction significantly improved model performance, emphasizing the importance of matching raw measurement data to high-quality CT reconstructions. The study furthermore suggests the need for more sophisticated noise simulation approaches to bridge the gap between simulated and real-world data in CT image denoising applications and gives insights into the challenges and opportunities in leveraging simulated data for machine learning in computational imaging.

Read more

8/16/2024

Low-Dose CT Reconstruction Using Dataset-free Learning
Total Score

0

Low-Dose CT Reconstruction Using Dataset-free Learning

Feng Wang, Renfang Wang, Hong Qiu

Low-Dose computer tomography (LDCT) is an ideal alternative to reduce radiation risk in clinical applications. Although supervised-deep-learning-based reconstruction methods have demonstrated superior performance compared to conventional model-driven reconstruction algorithms, they require collecting massive pairs of low-dose and norm-dose CT images for neural network training, which limits their practical application in LDCT imaging. In this paper, we propose an unsupervised and training data-free learning reconstruction method for LDCT imaging that avoids the requirement for training data. The proposed method is a post-processing technique that aims to enhance the initial low-quality reconstruction results, and it reconstructs the high-quality images by neural work training that minimizes the $ell_1$-norm distance between the CT measurements and their corresponding simulated sinogram data, as well as the total variation (TV) value of the reconstructed image. Moreover, the proposed method does not require to set the weights for both the data fidelity term and the plenty term. Experimental results on the AAPM challenge data and LoDoPab-CT data demonstrate that the proposed method is able to effectively suppress the noise and preserve the tiny structures. Also, these results demonstrate the rapid convergence and low computational cost of the proposed method. The source code is available at url{https://github.com/linfengyu77/IRLDCT}.

Read more

5/24/2024

Multi-view X-ray Image Synthesis with Multiple Domain Disentanglement from CT Scans
Total Score

0

Multi-view X-ray Image Synthesis with Multiple Domain Disentanglement from CT Scans

Lixing Tan, Shuang Song, Kangneng Zhou, Chengbo Duan, Lanying Wang, Huayang Ren, Linlin Liu, Wei Zhang, Ruoxiu Xiao

X-ray images play a vital role in the intraoperative processes due to their high resolution and fast imaging speed and greatly promote the subsequent segmentation, registration and reconstruction. However, over-dosed X-rays superimpose potential risks to human health to some extent. Data-driven algorithms from volume scans to X-ray images are restricted by the scarcity of paired X-ray and volume data. Existing methods are mainly realized by modelling the whole X-ray imaging procedure. In this study, we propose a learning-based approach termed CT2X-GAN to synthesize the X-ray images in an end-to-end manner using the content and style disentanglement from three different image domains. Our method decouples the anatomical structure information from CT scans and style information from unpaired real X-ray images/ digital reconstructed radiography (DRR) images via a series of decoupling encoders. Additionally, we introduce a novel consistency regularization term to improve the stylistic resemblance between synthesized X-ray images and real X-ray images. Meanwhile, we also impose a supervised process by computing the similarity of computed real DRR and synthesized DRR images. We further develop a pose attention module to fully strengthen the comprehensive information in the decoupled content code from CT scans, facilitating high-quality multi-view image synthesis in the lower 2D space. Extensive experiments were conducted on the publicly available CTSpine1K dataset and achieved 97.8350, 0.0842 and 3.0938 in terms of FID, KID and defined user-scored X-ray similarity, respectively. In comparison with 3D-aware methods ($pi$-GAN, EG3D), CT2X-GAN is superior in improving the synthesis quality and realistic to the real X-ray images.

Read more

8/1/2024