A Data Mining-Based Dynamical Anomaly Detection Method for Integrating with an Advance Metering System

Read original: arXiv:2405.02574 - Published 5/7/2024 by Sarit Maitra
Total Score

0

📊

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Building operations consume 30% of total power usage and contribute 26% of global power-related emissions.
  • Monitoring and early detection of anomalies at the meter level are essential for residential and commercial buildings.
  • This work investigates both supervised and unsupervised approaches and introduces a dynamic anomaly detection system.

Plain English Explanation

Buildings use a significant amount of power, around 30% of the total, and are responsible for a large portion, 26%, of global power-related emissions. Monitoring the power usage of buildings and quickly identifying any unusual patterns or problems is crucial. This paper explores both supervised and unsupervised methods to create a dynamic system that can detect anomalies in real-time at the individual meter level.

The dynamic system uses a supervised machine learning model called Light Gradient Boosting and an unsupervised autoencoder model. These models are designed to adapt to changes in the data over time by using a dynamic threshold based on the Mahalanobis distance and moving averages. This allows the system to continuously detect unusual power usage patterns and provide early warnings, which can help prevent financial losses and potential safety issues like fires.

Technical Explanation

The paper introduces a dynamic anomaly detection system that utilizes both supervised and unsupervised approaches. The supervised component is a Light Gradient Boosting machine, while the unsupervised component is an autoencoder with a dynamic threshold.

The dynamic threshold is based on the Mahalanobis distance and moving averages, which allows the system to adapt to changes in the data distribution over time. This adaptability is crucial, as building power consumption patterns can shift gradually.

The effectiveness of the proposed system is evaluated using real-world power consumption data collected from smart metering systems. This real-world testing ensures the system's performance is validated under realistic conditions.

Critical Analysis

The paper does not provide detailed information about the specific architectures of the Light Gradient Boosting machine or the autoencoder used in the system. More details on the model designs and hyperparameter tuning would be helpful for researchers looking to replicate or build upon this work.

Additionally, the paper does not discuss the computational complexity or real-time performance of the proposed system. Understanding the system's resource requirements and latency would be valuable for assessing its practicality in real-world deployments.

Conclusion

This research presents a dynamic anomaly detection system that combines supervised and unsupervised approaches to monitor and quickly identify unusual power consumption patterns in buildings. By providing early warnings, the system can help prevent financial losses and potential safety issues, contributing to more efficient and safer building operations. The adaptability of the system to changes in data over time is a key strength, though more technical details would be helpful for further research and development.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

📊

Total Score

0

A Data Mining-Based Dynamical Anomaly Detection Method for Integrating with an Advance Metering System

Sarit Maitra

Building operations consume 30% of total power consumption and contribute 26% of global power-related emissions. Therefore, monitoring, and early detection of anomalies at the meter level are essential for residential and commercial buildings. This work investigates both supervised and unsupervised approaches and introduces a dynamic anomaly detection system. The system introduces a supervised Light Gradient Boosting machine and an unsupervised autoencoder with a dynamic threshold. This system is designed to provide real-time detection of anomalies at the meter level. The proposed dynamical system comes with a dynamic threshold based on the Mahalanobis distance and moving averages. This approach allows the system to adapt to changes in the data distribution over time. The effectiveness of the proposed system is evaluated using real-life power consumption data collected from smart metering systems. This empirical testing ensures that the system's performance is validated under real-world conditions. By detecting unusual data movements and providing early warnings, the proposed system contributes significantly to visual analytics and decision science. Early detection of anomalies enables timely troubleshooting, preventing financial losses and potential disasters such as fire incidents.

Read more

5/7/2024

Total Score

0

A Real-time Anomaly Detection Using Convolutional Autoencoder with Dynamic Threshold

Sarit Maitra, Sukanya Kundu, Aishwarya Shankar

The majority of modern consumer-level energy is generated by real-time smart metering systems. These frequently contain anomalies, which prevent reliable estimates of the series' evolution. This work introduces a hybrid modeling approach combining statistics and a Convolutional Autoencoder with a dynamic threshold. The threshold is determined based on Mahalanobis distance and moving averages. It has been tested using real-life energy consumption data collected from smart metering systems. The solution includes a real-time, meter-level anomaly detection system that connects to an advanced monitoring system. This makes a substantial contribution by detecting unusual data movements and delivering an early warning. Early detection and subsequent troubleshooting can financially benefit organizations and consumers and prevent disasters from occurring.

Read more

4/9/2024

Acquiring Better Load Estimates by Combining Anomaly and Change-point Detection in Power Grid Time-series Measurements
Total Score

0

Acquiring Better Load Estimates by Combining Anomaly and Change-point Detection in Power Grid Time-series Measurements

Roel Bouman, Linda Schmeitz, Luco Buise, Jacco Heres, Yuliya Shapovalova, Tom Heskes

In this paper we present novel methodology for automatic anomaly and switch event filtering to improve load estimation in power grid systems. By leveraging unsupervised methods with supervised optimization, our approach prioritizes interpretability while ensuring robust and generalizable performance on unseen data. Through experimentation, a combination of binary segmentation for change point detection and statistical process control for anomaly detection emerges as the most effective strategy, specifically when ensembled in a novel sequential manner. Results indicate the clear wasted potential when filtering is not applied. The automatic load estimation is also fairly accurate, with approximately 90% of estimates falling within a 10% error margin, with only a single significant failure in both the minimum and maximum load estimates across 60 measurements in the test set. Our methodology's interpretability makes it particularly suitable for critical infrastructure planning, thereby enhancing decision-making processes.

Read more

5/29/2024

📊

Total Score

0

Research on Dynamic Data Flow Anomaly Detection based on Machine Learning

Liyang Wang, Yu Cheng, Hao Gong, Jiacheng Hu, Xirui Tang, Iris Li

The sophistication and diversity of contemporary cyberattacks have rendered the use of proxies, gateways, firewalls, and encrypted tunnels as a standalone defensive strategy inadequate. Consequently, the proactive identification of data anomalies has emerged as a prominent area of research within the field of data security. The majority of extant studies concentrate on sample equilibrium data, with the consequence that the detection effect is not optimal in the context of unbalanced data. In this study, the unsupervised learning method is employed to identify anomalies in dynamic data flows. Initially, multi-dimensional features are extracted from real-time data, and a clustering algorithm is utilised to analyse the patterns of the data. This enables the potential outliers to be automatically identified. By clustering similar data, the model is able to detect data behaviour that deviates significantly from normal traffic without the need for labelled data. The results of the experiments demonstrate that the proposed method exhibits high accuracy in the detection of anomalies across a range of scenarios. Notably, it demonstrates robust and adaptable performance, particularly in the context of unbalanced data.

Read more

9/24/2024