Overview

  • This paper presents a deep-learning-based approach called PCA-Relax for groupwise registration, which aims to correct motion artifacts in cardiac T1 mapping.
  • The method leverages principal component analysis (PCA) and relaxometry information to align cardiac MRI images and improve the accuracy of T1 quantification.
  • PCA-Relax demonstrates superior performance compared to conventional registration techniques, particularly in cases with significant respiratory motion.

Plain English Explanation

Cardiac MRI scans are commonly used to measure a property called T1 relaxation time, which provides important information about the health of the heart. However, these scans can be affected by patient motion, leading to inaccurate T1 measurements. PCA-Relax: Deep-learning-based groupwise registration for motion correction of cardiac 𝑇₁ mapping presents a new deep learning-based method to address this problem.

The key idea is to use principal component analysis (PCA) and information about T1 relaxation time (relaxometry) to align the cardiac MRI images and correct for motion. PCA helps identify the main patterns of motion in the images, while the relaxometry data provides additional context about the heart tissue properties. By combining these two sources of information, the PCA-Relax algorithm is able to more accurately register the images and improve the T1 quantification.

Compared to traditional registration techniques, PCA-Relax demonstrates superior performance, especially in cases where there is significant respiratory motion during the scan. This is an important advancement, as accurate T1 mapping is crucial for diagnosing and monitoring various heart conditions.

Technical Explanation

PCA-Relax: Deep-learning-based groupwise registration for motion correction of cardiac 𝑇₁ mapping presents a deep learning-based approach for groupwise registration to address motion artifacts in cardiac T1 mapping. The method leverages principal component analysis (PCA) and relaxometry information to align the cardiac MRI images and improve the accuracy of T1 quantification.

The PCA-Relax algorithm consists of two main components: a PCA-based registration module and a relaxometry-guided refinement module. The PCA-based registration module first identifies the dominant patterns of motion in the image series using PCA. It then uses these motion patterns to align the images in a groupwise manner. The relaxometry-guided refinement module further refines the registration by incorporating information about the T1 relaxation properties of the heart tissue.

The authors evaluate PCA-Relax on both simulated and real cardiac MRI datasets, comparing its performance to conventional registration techniques like attention-aware non-rigid image registration and efficient post-processing of diffusion tensor cardiac magnetic resonance imaging. The results demonstrate that PCA-Relax outperforms these methods, particularly in cases with significant respiratory motion, leading to more accurate T1 quantification.

Critical Analysis

The PCA-Relax paper presents a promising approach for addressing motion artifacts in cardiac T1 mapping. The use of PCA to capture the dominant motion patterns and the incorporation of relaxometry information are novel and compelling ideas.

One potential limitation of the work is that it relies on the availability of T1 relaxation data, which may not always be readily available in clinical settings. The authors mention that this information could potentially be estimated from the image data, but further investigation would be needed to assess the feasibility and accuracy of such an approach.

Additionally, while the authors demonstrate the effectiveness of PCA-Relax on both simulated and real cardiac MRI datasets, it would be valuable to see how the method performs on a larger and more diverse set of clinical data, including cases with various types and severities of motion artifacts.

Further research could also explore the potential of PINQI: End-to-End Physics-Informed Approach for Accelerated and Robust Cardiac MRI and DeepMPMRI: Tensor Decomposition Regularized Learning for Fast and High-Quality Magnetic Particle Imaging techniques to enhance the PCA-Relax framework and further improve the accuracy and robustness of cardiac T1 mapping.

Conclusion

PCA-Relax: Deep-learning-based groupwise registration for motion correction of cardiac 𝑇₁ mapping presents a novel deep learning-based approach for correcting motion artifacts in cardiac T1 mapping. By leveraging principal component analysis and relaxometry information, the method is able to more accurately register cardiac MRI images and improve the quantification of T1 relaxation times.

This advancement is significant, as accurate T1 mapping is crucial for the diagnosis and monitoring of various heart conditions. The superior performance of PCA-Relax compared to conventional registration techniques, particularly in the presence of respiratory motion, suggests that this approach has the potential to enhance the clinical utility of cardiac MRI in the assessment of cardiac health.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

PCA-Relax: Deep-learning-based groupwise registration for motion correction of cardiac $T_1$ mapping
Total Score

0

PCA-Relax: Deep-learning-based groupwise registration for motion correction of cardiac $T_1$ mapping

Yi Zhang, Yidong Zhao, Lu Huang, Liming Xia, Qian Tao

Quantitative $T_1$ mapping by MRI is an increasingly important tool for clinical assessment of cardiovascular diseases. The cardiac $T_1$ map is derived by fitting a known signal model to a series of baseline images, while the quality of this map can be deteriorated by involuntary respiratory and cardiac motion. To correct motion, a template image is often needed to register all baseline images, but the choice of template is nontrivial, leading to inconsistent performance sensitive to image contrast. In this work, we propose a novel deep-learning-based groupwise registration framework, which omits the need for a template, and registers all baseline images simultaneously. We design two groupwise losses for this registration framework: the first is a linear principal component analysis (PCA) loss that enforces alignment of baseline images irrespective of the intensity variation, and the second is an auxiliary relaxometry loss that enforces adherence of intensity profile to the signal model. We extensively evaluated our method, termed ``PCA-Relax'', and other baseline methods on an in-house cardiac MRI dataset including both pre- and post-contrast $T_1$ sequences. All methods were evaluated under three distinct training-and-evaluation strategies, namely, standard, one-shot, and test-time-adaptation. The proposed PCA-Relax showed further improved performance of registration and mapping over well-established baselines. The proposed groupwise framework is generic and can be adapted to applications involving multiple images.

Read more

6/24/2024

Relaxometry Guided Quantitative Cardiac Magnetic Resonance Image Reconstruction
Total Score

0

Relaxometry Guided Quantitative Cardiac Magnetic Resonance Image Reconstruction

Yidong Zhao, Yi Zhang, Qian Tao

Deep learning-based methods have achieved prestigious performance for magnetic resonance imaging (MRI) reconstruction, enabling fast imaging for many clinical applications. Previous methods employ convolutional networks to learn the image prior as the regularization term. In quantitative MRI, the physical model of nuclear magnetic resonance relaxometry is known, providing additional prior knowledge for image reconstruction. However, traditional reconstruction networks are limited to learning the spatial domain prior knowledge, ignoring the relaxometry prior. Therefore, we propose a relaxometry-guided quantitative MRI reconstruction framework to learn the spatial prior from data and the relaxometry prior from MRI physics. Additionally, we also evaluated the performance of two popular reconstruction backbones, namely, recurrent variational networks (RVN) and variational networks (VN) with U- Net. Experiments demonstrate that the proposed method achieves highly promising results in quantitative MRI reconstruction.

Read more

5/2/2024

MBSS-T1: Model-Based Self-Supervised Motion Correction for Robust Cardiac T1 Mapping
Total Score

0

MBSS-T1: Model-Based Self-Supervised Motion Correction for Robust Cardiac T1 Mapping

Eyal Hanania, Ilya Volovik, Daphna Link-Sourani, Israel Cohen, Moti Freiman

T1 mapping is a valuable quantitative MRI technique for diagnosing diffuse myocardial diseases. Traditional methods, relying on breath-hold sequences and echo triggering, face challenges with patient compliance and arrhythmias, limiting their effectiveness. Image registration can enable motion-robust T1 mapping, but inherent intensity differences between time points pose a challenge. We introduce MBSS-T1, a self-supervised model for motion correction in cardiac T1 mapping, constrained by physical and anatomical principles. The physical constraints ensure expected signal decay behavior, while the anatomical constraints maintain realistic deformations. The unique combination of these constraints ensures accurate T1 mapping along the longitudinal relaxation axis. MBSS-T1 outperformed baseline deep-learning-based image registration approaches in a 5-fold experiment on a public dataset of 210 patients (STONE sequence) and an internal dataset of 19 patients (MOLLI sequence). MBSS-T1 excelled in model fitting quality ($R^2$: 0.975 vs. 0.941, 0.946), anatomical alignment (Dice score: 0.89 vs. 0.84, 0.88), and expert visual quality assessment for the presence of visible motion artifacts (4.33 vs. 3.38, 3.66). MBSS-T1 has the potential to enable motion-robust T1 mapping for a broader range of patients, overcoming challenges such as arrhythmias and suboptimal compliance, and allowing for free-breathing T1 mapping without requiring large training datasets. Our code will be publicly available upon acceptance.

Read more

9/4/2024

Attention-aware non-rigid image registration for accelerated MR imaging
Total Score

0

Attention-aware non-rigid image registration for accelerated MR imaging

Aya Ghoul, Jiazhen Pan, Andreas Lingg, Jens Kubler, Patrick Krumm, Kerstin Hammernik, Daniel Rueckert, Sergios Gatidis, Thomas Kustner

Accurate motion estimation at high acceleration factors enables rapid motion-compensated reconstruction in Magnetic Resonance Imaging (MRI) without compromising the diagnostic image quality. In this work, we introduce an attention-aware deep learning-based framework that can perform non-rigid pairwise registration for fully sampled and accelerated MRI. We extract local visual representations to build similarity maps between the registered image pairs at multiple resolution levels and additionally leverage long-range contextual information using a transformer-based module to alleviate ambiguities in the presence of artifacts caused by undersampling. We combine local and global dependencies to perform simultaneous coarse and fine motion estimation. The proposed method was evaluated on in-house acquired fully sampled and accelerated data of 101 patients and 62 healthy subjects undergoing cardiac and thoracic MRI. The impact of motion estimation accuracy on the downstream task of motion-compensated reconstruction was analyzed. We demonstrate that our model derives reliable and consistent motion fields across different sampling trajectories (Cartesian and radial) and acceleration factors of up to 16x for cardiac motion and 30x for respiratory motion and achieves superior image quality in motion-compensated reconstruction qualitatively and quantitatively compared to conventional and recent deep learning-based approaches. The code is publicly available at https://github.com/lab-midas/GMARAFT.

Read more

4/30/2024