MBSS-T1: Model-Based Self-Supervised Motion Correction for Robust Cardiac T1 Mapping

Read original: arXiv:2408.11992 - Published 9/4/2024 by Eyal Hanania, Ilya Volovik, Daphna Link-Sourani, Israel Cohen, Moti Freiman
Total Score

0

MBSS-T1: Model-Based Self-Supervised Motion Correction for Robust Cardiac T1 Mapping

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • MBSS-T1 is a novel method for model-based, self-supervised motion correction in cardiac T1 mapping
  • It aims to improve the robustness and accuracy of T1 mapping by addressing motion artifacts
  • The approach combines a motion model with self-supervised learning to correct for patient motion during the imaging process

Plain English Explanation

MBSS-T1: Model-Based Self-Supervised Motion Correction for Robust Cardiac T1 Mapping is a research paper that introduces a new technique for improving the accuracy of a medical imaging process called cardiac T1 mapping.

T1 mapping is used to measure the properties of the heart muscle, which can provide important information for diagnosing and monitoring certain heart conditions. However, patient motion during the imaging process can introduce errors and make the results less reliable.

The MBSS-T1 method addresses this problem by combining two key ideas:

  1. Motion Model: The researchers developed a mathematical model that can predict how the heart moves and deforms during the imaging process. This motion model is a crucial component of the approach.

  2. Self-Supervised Learning: The researchers also developed a machine learning system that can "teach itself" to correct for motion artifacts without requiring any additional manual labeling or correction of the images. This self-supervised learning approach allows the method to adapt to different patients and imaging conditions.

By integrating the motion model and self-supervised learning, MBSS-T1 is able to automatically detect and correct for patient motion, leading to more accurate and robust T1 mapping results. This could have important implications for improving the diagnosis and monitoring of heart disease using this medical imaging technique.

Technical Explanation

The MBSS-T1 method consists of two main components:

  1. Motion Model: The researchers developed a physics-based model of cardiac motion that can predict how the heart deforms and moves during the imaging process. This motion model is parameterized by a set of motion parameters that capture the complex 3D motion of the heart.

  2. Self-Supervised Learning: The researchers trained a deep neural network to estimate the motion parameters from the acquired T1 mapping images in a self-supervised manner. This means the network learns to correct for motion without any additional labeled data or manual corrections.

During inference, the MBSS-T1 method first uses the motion model to generate a predicted motion field for the current patient. It then applies this motion field to the acquired T1 mapping images to correct for the motion artifacts. The corrected images are then used to generate the final T1 maps.

The key innovation of MBSS-T1 is that it combines the physics-based motion model with the self-supervised learning approach. This allows the method to effectively adapt to different patients and imaging conditions, leading to more robust and accurate T1 mapping results compared to previous motion correction techniques.

Critical Analysis

The MBSS-T1 paper acknowledges several limitations and areas for future research:

  • The motion model assumes a simplified cardiac deformation and may not capture all the complex motion patterns seen in practice. Incorporating more advanced motion modeling techniques could further improve performance.

  • The self-supervised learning approach relies on the quality of the initial T1 mapping images, which may be suboptimal due to motion artifacts. Exploring ways to bootstrap the learning process or incorporate additional sources of information could help address this.

  • The method was evaluated on a relatively small dataset of cardiac MRI scans. Validating the approach on larger, more diverse datasets would be important to assess its robustness and generalizability.

  • The paper does not provide a detailed analysis of the computational complexity and runtime of the MBSS-T1 method. Understanding the practical deployment considerations would be valuable for real-world applications.

Overall, the MBSS-T1 method presents a promising approach to addressing a significant challenge in cardiac imaging. While the current results are encouraging, further research and development would be needed to fully realize the potential of this technique.

Conclusion

MBSS-T1 introduces a novel model-based, self-supervised motion correction method for improving the accuracy and robustness of cardiac T1 mapping. By combining a physics-based motion model with a self-supervised learning approach, the technique can effectively detect and correct for patient motion, leading to more reliable T1 mapping results.

The key contributions of this work are the integration of the motion model and self-supervised learning, which allows the method to adapt to different patients and imaging conditions without requiring additional labeled data or manual corrections. This could have important implications for enhancing the clinical utility of cardiac T1 mapping for the diagnosis and monitoring of heart disease.

While the current results are promising, the paper also highlights several areas for further research and development, such as improving the motion modeling, exploring additional learning strategies, and validating the approach on larger datasets. Addressing these limitations could help unlock the full potential of this innovative motion correction technique for cardiac imaging.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on š• ā†’

Related Papers

MBSS-T1: Model-Based Self-Supervised Motion Correction for Robust Cardiac T1 Mapping
Total Score

0

MBSS-T1: Model-Based Self-Supervised Motion Correction for Robust Cardiac T1 Mapping

Eyal Hanania, Ilya Volovik, Daphna Link-Sourani, Israel Cohen, Moti Freiman

T1 mapping is a valuable quantitative MRI technique for diagnosing diffuse myocardial diseases. Traditional methods, relying on breath-hold sequences and echo triggering, face challenges with patient compliance and arrhythmias, limiting their effectiveness. Image registration can enable motion-robust T1 mapping, but inherent intensity differences between time points pose a challenge. We introduce MBSS-T1, a self-supervised model for motion correction in cardiac T1 mapping, constrained by physical and anatomical principles. The physical constraints ensure expected signal decay behavior, while the anatomical constraints maintain realistic deformations. The unique combination of these constraints ensures accurate T1 mapping along the longitudinal relaxation axis. MBSS-T1 outperformed baseline deep-learning-based image registration approaches in a 5-fold experiment on a public dataset of 210 patients (STONE sequence) and an internal dataset of 19 patients (MOLLI sequence). MBSS-T1 excelled in model fitting quality ($R^2$: 0.975 vs. 0.941, 0.946), anatomical alignment (Dice score: 0.89 vs. 0.84, 0.88), and expert visual quality assessment for the presence of visible motion artifacts (4.33 vs. 3.38, 3.66). MBSS-T1 has the potential to enable motion-robust T1 mapping for a broader range of patients, overcoming challenges such as arrhythmias and suboptimal compliance, and allowing for free-breathing T1 mapping without requiring large training datasets. Our code will be publicly available upon acceptance.

Read more

9/4/2024

PCA-Relax: Deep-learning-based groupwise registration for motion correction of cardiac $T_1$ mapping
Total Score

0

PCA-Relax: Deep-learning-based groupwise registration for motion correction of cardiac $T_1$ mapping

Yi Zhang, Yidong Zhao, Lu Huang, Liming Xia, Qian Tao

Quantitative $T_1$ mapping by MRI is an increasingly important tool for clinical assessment of cardiovascular diseases. The cardiac $T_1$ map is derived by fitting a known signal model to a series of baseline images, while the quality of this map can be deteriorated by involuntary respiratory and cardiac motion. To correct motion, a template image is often needed to register all baseline images, but the choice of template is nontrivial, leading to inconsistent performance sensitive to image contrast. In this work, we propose a novel deep-learning-based groupwise registration framework, which omits the need for a template, and registers all baseline images simultaneously. We design two groupwise losses for this registration framework: the first is a linear principal component analysis (PCA) loss that enforces alignment of baseline images irrespective of the intensity variation, and the second is an auxiliary relaxometry loss that enforces adherence of intensity profile to the signal model. We extensively evaluated our method, termed ``PCA-Relax'', and other baseline methods on an in-house cardiac MRI dataset including both pre- and post-contrast $T_1$ sequences. All methods were evaluated under three distinct training-and-evaluation strategies, namely, standard, one-shot, and test-time-adaptation. The proposed PCA-Relax showed further improved performance of registration and mapping over well-established baselines. The proposed groupwise framework is generic and can be adapted to applications involving multiple images.

Read more

6/24/2024

šŸ¤·

Total Score

0

MotionTTT: 2D Test-Time-Training Motion Estimation for 3D Motion Corrected MRI

Tobit Klug, Kun Wang, Stefan Ruschke, Reinhard Heckel

A major challenge of the long measurement times in magnetic resonance imaging (MRI), an important medical imaging technology, is that patients may move during data acquisition. This leads to severe motion artifacts in the reconstructed images and volumes. In this paper, we propose a deep learning-based test-time-training method for accurate motion estimation. The key idea is that a neural network trained for motion-free reconstruction has a small loss if there is no motion, thus optimizing over motion parameters passed through the reconstruction network enables accurate estimation of motion. The estimated motion parameters enable to correct for the motion and to reconstruct accurate motion-corrected images. Our method uses 2D reconstruction networks to estimate rigid motion in 3D, and constitutes the first deep learning based method for 3D rigid motion estimation towards 3D-motion-corrected MRI. We show that our method can provably reconstruct motion parameters for a simple signal and neural network model. We demonstrate the effectiveness of our method for both retrospectively simulated motion and prospectively collected real motion-corrupted data.

Read more

9/17/2024

Whole Heart 3D+T Representation Learning Through Sparse 2D Cardiac MR Images
Total Score

0

Whole Heart 3D+T Representation Learning Through Sparse 2D Cardiac MR Images

Yundi Zhang, Chen Chen, Suprosanna Shit, Sophie Starck, Daniel Rueckert, Jiazhen Pan

Cardiac Magnetic Resonance (CMR) imaging serves as the gold-standard for evaluating cardiac morphology and function. Typically, a multi-view CMR stack, covering short-axis (SA) and 2/3/4-chamber long-axis (LA) views, is acquired for a thorough cardiac assessment. However, efficiently streamlining the complex, high-dimensional 3D+T CMR data and distilling compact, coherent representation remains a challenge. In this work, we introduce a whole-heart self-supervised learning framework that utilizes masked imaging modeling to automatically uncover the correlations between spatial and temporal patches throughout the cardiac stacks. This process facilitates the generation of meaningful and well-clustered heart representations without relying on the traditionally required, and often costly, labeled data. The learned heart representation can be directly used for various downstream tasks. Furthermore, our method demonstrates remarkable robustness, ensuring consistent representations even when certain CMR planes are missing/flawed. We train our model on 14,000 unlabeled CMR data from UK BioBank and evaluate it on 1,000 annotated data. The proposed method demonstrates superior performance to baselines in tasks that demand comprehensive 3D+T cardiac information, e.g. cardiac phenotype (ejection fraction and ventricle volume) prediction and multi-plane/multi-frame CMR segmentation, highlighting its effectiveness in extracting comprehensive cardiac features that are both anatomically and pathologically relevant.

Read more