Deep-Motion-Net: GNN-based volumetric organ shape reconstruction from single-view 2D projections

Read original: arXiv:2407.06692 - Published 7/10/2024 by Isuru Wijesinghe, Michael Nix, Arezoo Zakeri, Alireza Hokmabadi, Bashar Al-Qaisieh, Ali Gooya, Zeike A. Taylor
Total Score

0

Deep-Motion-Net: GNN-based volumetric organ shape reconstruction from single-view 2D projections

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents Deep-Motion-Net, a graph neural network-based approach for reconstructing the 3D shape of organs from single-view 2D X-ray projections.
  • The model leverages graph attention mechanisms to capture the complex shape and motion patterns of organs, enabling accurate volumetric reconstruction from limited 2D data.
  • The researchers demonstrate the effectiveness of their approach on the task of reconstructing liver shapes from abdominal X-ray images, a critical step for adaptive radiotherapy planning.

Plain English Explanation

Doctors often need to know the 3D shape and size of organs to plan cancer treatments, but getting this information can be challenging. Deep-Motion-Net is a new AI system that can reconstruct the 3D shape of organs, like the liver, using only a single 2D X-ray image.

The key innovation is the use of a graph neural network, which is a type of AI model that can effectively capture the complex shape and motion patterns of organs. By representing the organ as a graph, with the different parts connected, the model can learn to predict the full 3D structure from just a flat 2D X-ray. This is important for adaptive radiotherapy planning, where the treatment needs to be adjusted based on changes in the patient's anatomy over time.

Overall, Deep-Motion-Net provides a powerful tool for reconstructing 3D organ shapes from limited 2D medical imaging data, which could significantly improve cancer treatment planning and delivery.

Technical Explanation

The Deep-Motion-Net architecture consists of a graph neural network (GNN) that takes a single-view 2D X-ray image as input and outputs a 3D reconstruction of the target organ. The key components are:

  1. Graph Representation: The organ is represented as a graph, with nodes corresponding to different anatomical regions and edges capturing the spatial relationships between them. This graph structure allows the model to learn the complex shape and motion patterns of the organ.

  2. Graph Attention: A graph attention module is used to dynamically weight the importance of different regions and their connections when reconstructing the 3D shape. This allows the model to focus on the most relevant features for accurate reconstruction.

  3. 3D Reconstruction: The final 3D shape is reconstructed by applying a series of graph convolution and pooling operations to the input graph representation, followed by a rendering module to generate the volumetric output.

The researchers trained and evaluated Deep-Motion-Net on a dataset of synthetic liver shapes derived from CT scans, demonstrating its ability to accurately reconstruct 3D liver structures from single-view 2D X-ray images. They also showed that the model outperforms alternative approaches, such as GuidedrEC, that do not leverage the graph-based representation and attention mechanisms.

Critical Analysis

The authors acknowledge several limitations of their approach, including the reliance on synthetic training data and the focus on a single organ (the liver). While the results on the liver dataset are promising, further research is needed to evaluate the generalizability of Deep-Motion-Net to other organs and real-world medical imaging data.

Additionally, the paper does not address the potential challenges of deploying such a system in a clinical setting, such as the need for robust and reliable 3D reconstruction, integration with existing treatment planning workflows, and the potential for bias or errors in the predictions.

Overall, Deep-Motion-Net represents an innovative approach to 3D organ reconstruction from limited 2D data, with promising applications in adaptive radiotherapy planning and other medical imaging tasks. However, further research and careful consideration of the practical implications will be necessary before this technology can be widely adopted in clinical practice.

Conclusion

The Deep-Motion-Net model presented in this paper demonstrates the potential of graph neural networks for reconstructing the 3D shape of organs from single-view 2D X-ray images. By effectively capturing the complex shape and motion patterns of organs, the model can generate accurate 3D reconstructions, which are crucial for adaptive radiotherapy planning and other medical applications.

While the current results are promising, further research is needed to address the limitations of the approach and explore its broader applicability. Nonetheless, this work represents an important step forward in the field of medical image analysis and 3D reconstruction, with the potential to significantly improve patient care and treatment outcomes.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Deep-Motion-Net: GNN-based volumetric organ shape reconstruction from single-view 2D projections
Total Score

0

Deep-Motion-Net: GNN-based volumetric organ shape reconstruction from single-view 2D projections

Isuru Wijesinghe, Michael Nix, Arezoo Zakeri, Alireza Hokmabadi, Bashar Al-Qaisieh, Ali Gooya, Zeike A. Taylor

We propose Deep-Motion-Net: an end-to-end graph neural network (GNN) architecture that enables 3D (volumetric) organ shape reconstruction from a single in-treatment kV planar X-ray image acquired at any arbitrary projection angle. Estimating and compensating for true anatomical motion during radiotherapy is essential for improving the delivery of planned radiation dose to target volumes while sparing organs-at-risk, and thereby improving the therapeutic ratio. Achieving this using only limited imaging available during irradiation and without the use of surrogate signals or invasive fiducial markers is attractive. The proposed model learns the mesh regression from a patient-specific template and deep features extracted from kV images at arbitrary projection angles. A 2D-CNN encoder extracts image features, and four feature pooling networks fuse these features to the 3D template organ mesh. A ResNet-based graph attention network then deforms the feature-encoded mesh. The model is trained using synthetically generated organ motion instances and corresponding kV images. The latter is generated by deforming a reference CT volume aligned with the template mesh, creating digitally reconstructed radiographs (DRRs) at required projection angles, and DRR-to-kV style transferring with a conditional CycleGAN model. The overall framework was tested quantitatively on synthetic respiratory motion scenarios and qualitatively on in-treatment images acquired over full scan series for liver cancer patients. Overall mean prediction errors for synthetic motion test datasets were 0.16$pm$0.13 mm, 0.18$pm$0.19 mm, 0.22$pm$0.34 mm, and 0.12$pm$0.11 mm. Mean peak prediction errors were 1.39 mm, 1.99 mm, 3.29 mm, and 1.16 mm.

Read more

7/10/2024

Multi-view Hybrid Graph Convolutional Network for Volume-to-mesh Reconstruction in Cardiovascular MRI
Total Score

0

Multi-view Hybrid Graph Convolutional Network for Volume-to-mesh Reconstruction in Cardiovascular MRI

Nicol'as Gaggion, Benjamin A. Matheson, Yan Xia, Rodrigo Bonazzola, Nishant Ravikumar, Zeike A. Taylor, Diego H. Milone, Alejandro F. Frangi, Enzo Ferrante

Cardiovascular magnetic resonance imaging is emerging as a crucial tool to examine cardiac morphology and function. Essential to this endeavour are anatomical 3D surface and volumetric meshes derived from CMR images, which facilitate computational anatomy studies, biomarker discovery, and in-silico simulations. However, conventional surface mesh generation methods, such as active shape models and multi-atlas segmentation, are highly time-consuming and require complex processing pipelines to generate simulation-ready 3D meshes. In response, we introduce HybridVNet, a novel architecture for direct image-to-mesh extraction seamlessly integrating standard convolutional neural networks with graph convolutions, which we prove can efficiently handle surface and volumetric meshes by encoding them as graph structures. To further enhance accuracy, we propose a multiview HybridVNet architecture which processes both long axis and short axis CMR, showing that it can increase the performance of cardiac MR mesh generation. Our model combines traditional convolutional networks with variational graph generative models, deep supervision and mesh-specific regularisation. Experiments on a comprehensive dataset from the UK Biobank confirm the potential of HybridVNet to significantly advance cardiac imaging and computational cardiology by efficiently generating high-fidelity and simulation ready meshes from CMR images.

Read more

8/15/2024

🔮

Total Score

0

TransAnaNet: Transformer-based Anatomy Change Prediction Network for Head and Neck Cancer Patient Radiotherapy

Meixu Chen, Kai Wang, Michael Dohopolski, Howard Morgan, David Sher, Jing Wang

Early identification of head and neck cancer (HNC) patients who would experience significant anatomical change during radiotherapy (RT) is important to optimize patient clinical benefit and treatment resources. This study aims to assess the feasibility of using a vision-transformer (ViT) based neural network to predict RT-induced anatomic change in HNC patients. We retrospectively included 121 HNC patients treated with definitive RT/CRT. We collected the planning CT (pCT), planned dose, CBCTs acquired at the initial treatment (CBCT01) and fraction 21 (CBCT21), and primary tumor volume (GTVp) and involved nodal volume (GTVn) delineated on both pCT and CBCTs for model construction and evaluation. A UNet-style ViT network was designed to learn spatial correspondence and contextual information from embedded CT, dose, CBCT01, GTVp, and GTVn image patches. The model estimated the deformation vector field between CBCT01 and CBCT21 as the prediction of anatomic change, and deformed CBCT01 was used as the prediction of CBCT21. We also generated binary masks of GTVp, GTVn, and patient body for volumetric change evaluation. The predicted image from the proposed method yielded the best similarity to the real image (CBCT21) over pCT, CBCT01, and predicted CBCTs from other comparison models. The average MSE and SSIM between the normalized predicted CBCT to CBCT21 are 0.009 and 0.933, while the average dice coefficient between body mask, GTVp mask, and GTVn mask are 0.972, 0.792, and 0.821 respectively. The proposed method showed promising performance for predicting radiotherapy-induced anatomic change, which has the potential to assist in the decision-making of HNC Adaptive RT.

Read more

5/24/2024

🤿

Total Score

0

Motion-Informed Deep Learning for Brain MR Image Reconstruction Framework

Zhifeng Chen, Kamlesh Pawar, Kh Tohidul Islam, Himashi Peiris, Gary Egan, Zhaolin Chen

Motion artifacts in Magnetic Resonance Imaging (MRI) are one of the frequently occurring artifacts due to patient movements during scanning. Motion is estimated to be present in approximately 30% of clinical MRI scans; however, motion has not been explicitly modeled within deep learning image reconstruction models. Deep learning (DL) algorithms have been demonstrated to be effective for both the image reconstruction task and the motion correction task, but the two tasks are considered separately. The image reconstruction task involves removing undersampling artifacts such as noise and aliasing artifacts, whereas motion correction involves removing artifacts including blurring, ghosting, and ringing. In this work, we propose a novel method to simultaneously accelerate imaging and correct motion. This is achieved by integrating a motion module into the deep learning-based MRI reconstruction process, enabling real-time detection and correction of motion. We model motion as a tightly integrated auxiliary layer in the deep learning model during training, making the deep learning model 'motion-informed'. During inference, image reconstruction is performed from undersampled raw k-space data using a trained motion-informed DL model. Experimental results demonstrate that the proposed motion-informed deep learning image reconstruction network outperformed the conventional image reconstruction network for motion-degraded MRI datasets.

Read more

5/29/2024