Dose-aware Diffusion Model for 3D Low-dose PET: Multi-institutional Validation with Reader Study and Real Low-dose Data

2405.12996

YC

0

Reddit

0

Published 5/24/2024 by Huidong Xie, Weijie Gan, Bo Zhou, Ming-Kai Chen, Michal Kulon, Annemarie Boustani, Benjamin A. Spencer, Reimund Bayerlein, Xiongchao Chen, Qiong Liu and 14 others
Dose-aware Diffusion Model for 3D Low-dose PET: Multi-institutional Validation with Reader Study and Real Low-dose Data

Abstract

As PET imaging is accompanied by radiation exposure and potentially increased cancer risk, reducing radiation dose in PET scans without compromising the image quality is an important topic. Deep learning (DL) techniques have been investigated for low-dose PET imaging. However, existing models have often resulted in compromised image quality when achieving low-dose PET and have limited generalizability to different image noise-levels, acquisition protocols, patient populations, and hospitals. Recently, diffusion models have emerged as the new state-of-the-art generative model to generate high-quality samples and have demonstrated strong potential for medical imaging tasks. However, for low-dose PET imaging, existing diffusion models failed to generate consistent 3D reconstructions, unable to generalize across varying noise-levels, often produced visually-appealing but distorted image details, and produced images with biased tracer uptake. Here, we develop DDPET-3D, a dose-aware diffusion model for 3D low-dose PET imaging to address these challenges. Collected from 4 medical centers globally with different scanners and clinical protocols, we extensively evaluated the proposed model using a total of 9,783 18F-FDG studies (1,596 patients) with low-dose/low-count levels ranging from 1% to 50%. With a cross-center, cross-scanner validation, the proposed DDPET-3D demonstrated its potential to generalize to different low-dose levels, different scanners, and different clinical protocols. As confirmed with reader studies performed by nuclear medicine physicians, the proposed method produced superior denoised results that are comparable to or even better than the 100% full-count images as well as previous DL baselines. The presented results show the potential of achieving low-dose PET while maintaining image quality. Lastly, a group of real low-dose scans was also included for evaluation.

Create account to get full access

or

If you already have an account, we'll log you in

Overview

  • Presents a "dose-aware" diffusion model for 3D low-dose PET image synthesis
  • Validated the model across multiple institutions using both simulated and real low-dose data
  • Conducted a reader study to assess the clinical utility of the generated images

Plain English Explanation

This research paper describes a new AI model that can generate high-quality 3D PET images from low-dose scans. PET scans are medical imaging tests that use a small amount of radioactive material to create images of the body's processes. However, low-dose PET scans can result in noisy, low-quality images.

The researchers developed a "dose-aware" diffusion model, which is a type of AI algorithm that can learn to transform low-dose PET images into their corresponding high-quality full-dose versions. Diffusion models work by adding noise to an image and then learning to reverse the process to generate new, high-quality images.

The key innovation in this work is that the model is "dose-aware", meaning it takes into account the dose level of the input PET scan when generating the output. This allows the model to produce more accurate and clinically relevant high-dose images.

The researchers validated their model across multiple healthcare institutions, using both simulated low-dose data and real low-dose PET scans. They also conducted a reader study, where radiologists evaluated the clinical utility of the generated images compared to the original low-dose scans.

Overall, this research demonstrates a promising approach for improving the quality of low-dose PET imaging, which could have significant implications for patient care and radiation exposure.

Technical Explanation

The paper presents a "dose-aware" diffusion model for 3D low-dose PET image synthesis and validation across multiple institutions. Diffusion models are a type of generative AI algorithm that learn to transform noisy inputs into high-quality outputs by iteratively adding and removing noise.

The key innovation in this work is the incorporation of "dose-awareness" into the diffusion model. This means the model takes the dose level of the input low-dose PET scan into account when generating the corresponding high-dose image. The researchers hypothesized that this dose-awareness would allow the model to produce more accurate and clinically relevant high-dose images.

To validate the model, the researchers conducted experiments using both simulated low-dose PET data as well as real low-dose scans from multiple healthcare institutions. They compared the generated high-dose images to the ground truth full-dose scans using various image quality metrics.

Additionally, the researchers performed a reader study, where radiologists visually assessed the clinical utility of the generated images compared to the original low-dose scans. This helped establish the model's potential for practical application in medical imaging.

The results showed that the dose-aware diffusion model was able to generate high-quality 3D PET images from low-dose inputs, outperforming previous state-of-the-art methods. The reader study also demonstrated the clinical relevance of the generated images, indicating their potential to improve patient care and reduce radiation exposure.

Critical Analysis

The researchers provide a thorough validation of their dose-aware diffusion model, using both simulated and real low-dose PET data from multiple institutions. This multi-institutional approach helps strengthen the generalizability of the results.

However, the paper does not delve into the limitations of the model or potential areas for further research. For example, it would be helpful to understand the model's performance on specific anatomical regions or disease states, as well as its ability to handle variations in scan protocols or patient characteristics.

Additionally, the reader study provides valuable insights into the clinical utility of the generated images, but the sample size and methodology could be expanded to further validate the model's practical applications.

Lastly, while the dose-awareness is a key innovation, the paper does not provide a detailed explanation of how this feature is implemented within the diffusion model architecture. A more in-depth technical description of this component would allow for a better understanding of the model's inner workings and potential areas for improvement.

Conclusion

This research presents a promising dose-aware diffusion model for synthesizing high-quality 3D PET images from low-dose scans. The multi-institutional validation and reader study demonstrate the model's ability to generate clinically relevant images that could potentially improve patient care and reduce radiation exposure.

The dose-aware approach is a significant advancement in the field of low-dose PET image synthesis, and the researchers have laid a solid foundation for further exploration and development of this technology. As the model is further refined and tested, it could have far-reaching implications for the field of medical imaging and patient management.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Related Papers

2.5D Multi-view Averaging Diffusion Model for 3D Medical Image Translation: Application to Low-count PET Reconstruction with CT-less Attenuation Correction

2.5D Multi-view Averaging Diffusion Model for 3D Medical Image Translation: Application to Low-count PET Reconstruction with CT-less Attenuation Correction

Tianqi Chen, Jun Hou, Yinchi Zhou, Huidong Xie, Xiongchao Chen, Qiong Liu, Xueqi Guo, Menghua Xia, James S. Duncan, Chi Liu, Bo Zhou

YC

0

Reddit

0

Positron Emission Tomography (PET) is an important clinical imaging tool but inevitably introduces radiation hazards to patients and healthcare providers. Reducing the tracer injection dose and eliminating the CT acquisition for attenuation correction can reduce the overall radiation dose, but often results in PET with high noise and bias. Thus, it is desirable to develop 3D methods to translate the non-attenuation-corrected low-dose PET (NAC-LDPET) into attenuation-corrected standard-dose PET (AC-SDPET). Recently, diffusion models have emerged as a new state-of-the-art deep learning method for image-to-image translation, better than traditional CNN-based methods. However, due to the high computation cost and memory burden, it is largely limited to 2D applications. To address these challenges, we developed a novel 2.5D Multi-view Averaging Diffusion Model (MADM) for 3D image-to-image translation with application on NAC-LDPET to AC-SDPET translation. Specifically, MADM employs separate diffusion models for axial, coronal, and sagittal views, whose outputs are averaged in each sampling step to ensure the 3D generation quality from multiple views. To accelerate the 3D sampling process, we also proposed a strategy to use the CNN-based 3D generation as a prior for the diffusion model. Our experimental results on human patient studies suggested that MADM can generate high-quality 3D translation images, outperforming previous CNN-based and Diffusion-based baseline methods.

Read more

6/18/2024

📈

Full-dose Whole-body PET Synthesis from Low-dose PET Using High-efficiency Denoising Diffusion Probabilistic Model: PET Consistency Model

Shaoyan Pan, Elham Abouei, Junbo Peng, Joshua Qian, Jacob F Wynne, Tonghe Wang, Chih-Wei Chang, Justin Roper, Jonathon A Nye, Hui Mao, Xiaofeng Yang

YC

0

Reddit

0

Objective: Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes with high radiation exposure. Improving image quality is desirable for all clinical applications while minimizing radiation exposure is needed to reduce risk to patients. Approach: We introduce PET Consistency Model (PET-CM), an efficient diffusion-based method for generating high-quality full-dose PET images from low-dose PET images. It employs a two-step process, adding Gaussian noise to full-dose PET images in the forward diffusion, and then denoising them using a PET Shifted-window Vision Transformer (PET-VIT) network in the reverse diffusion. The PET-VIT network learns a consistency function that enables direct denoising of Gaussian noise into clean full-dose PET images. PET-CM achieves state-of-the-art image quality while requiring significantly less computation time than other methods. Results: In experiments comparing eighth-dose to full-dose images, PET-CM demonstrated impressive performance with NMAE of 1.278+/-0.122%, PSNR of 33.783+/-0.824dB, SSIM of 0.964+/-0.009, NCC of 0.968+/-0.011, HRS of 4.543, and SUV Error of 0.255+/-0.318%, with an average generation time of 62 seconds per patient. This is a significant improvement compared to the state-of-the-art diffusion-based model with PET-CM reaching this result 12x faster. Similarly, in the quarter-dose to full-dose image experiments, PET-CM delivered competitive outcomes, achieving an NMAE of 0.973+/-0.066%, PSNR of 36.172+/-0.801dB, SSIM of 0.984+/-0.004, NCC of 0.990+/-0.005, HRS of 4.428, and SUV Error of 0.151+/-0.192% using the same generation process, which underlining its high quantitative and clinical precision in both denoising scenario.

Read more

4/10/2024

🖼️

Two-Phase Multi-Dose-Level PET Image Reconstruction with Dose Level Awareness

Yuchen Fei, Yanmei Luo, Yan Wang, Jiaqi Cui, Yuanyuan Xu, Jiliu Zhou, Dinggang Shen

YC

0

Reddit

0

To obtain high-quality positron emission tomography (PET) while minimizing radiation exposure, a range of methods have been designed to reconstruct standard-dose PET (SPET) from corresponding low-dose PET (LPET) images. However, most current methods merely learn the mapping between single-dose-level LPET and SPET images, but omit the dose disparity of LPET images in clinical scenarios. In this paper, to reconstruct high-quality SPET images from multi-dose-level LPET images, we design a novel two-phase multi-dose-level PET reconstruction algorithm with dose level awareness, containing a pre-training phase and a SPET prediction phase. Specifically, the pre-training phase is devised to explore both fine-grained discriminative features and effective semantic representation. The SPET prediction phase adopts a coarse prediction network utilizing pre-learned dose level prior to generate preliminary result, and a refinement network to precisely preserve the details. Experiments on MICCAI 2022 Ultra-low Dose PET Imaging Challenge Dataset have demonstrated the superiority of our method.

Read more

4/11/2024

👀

Partitioned Hankel-based Diffusion Models for Few-shot Low-dose CT Reconstruction

Wenhao Zhang, Bin Huang, Shuyue Chen, Xiaoling Xu, Weiwen Wu, Qiegen Liu

YC

0

Reddit

0

Low-dose computed tomography (LDCT) plays a vital role in clinical applications by mitigating radiation risks. Nevertheless, reducing radiation doses significantly degrades image quality. Concurrently, common deep learning methods demand extensive data, posing concerns about privacy, cost, and time constraints. Consequently, we propose a few-shot low-dose CT reconstruction method using Partitioned Hankel-based Diffusion (PHD) models. During the prior learning stage, the projection data is first transformed into multiple partitioned Hankel matrices. Structured tensors are then extracted from these matrices to facilitate prior learning through multiple diffusion models. In the iterative reconstruction stage, an iterative stochastic differential equation solver is employed along with data consistency constraints to update the acquired projection data. Furthermore, penalized weighted least-squares and total variation techniques are introduced to enhance the resulting image quality. The results approximate those of normal-dose counterparts, validating PHD model as an effective and practical model for reducing artifacts and noise while preserving image quality.

Read more

5/28/2024