Two-Phase Multi-Dose-Level PET Image Reconstruction with Dose Level Awareness

2404.01563

YC

0

Reddit

0

Published 4/11/2024 by Yuchen Fei, Yanmei Luo, Yan Wang, Jiaqi Cui, Yuanyuan Xu, Jiliu Zhou, Dinggang Shen

🖼️

Abstract

To obtain high-quality positron emission tomography (PET) while minimizing radiation exposure, a range of methods have been designed to reconstruct standard-dose PET (SPET) from corresponding low-dose PET (LPET) images. However, most current methods merely learn the mapping between single-dose-level LPET and SPET images, but omit the dose disparity of LPET images in clinical scenarios. In this paper, to reconstruct high-quality SPET images from multi-dose-level LPET images, we design a novel two-phase multi-dose-level PET reconstruction algorithm with dose level awareness, containing a pre-training phase and a SPET prediction phase. Specifically, the pre-training phase is devised to explore both fine-grained discriminative features and effective semantic representation. The SPET prediction phase adopts a coarse prediction network utilizing pre-learned dose level prior to generate preliminary result, and a refinement network to precisely preserve the details. Experiments on MICCAI 2022 Ultra-low Dose PET Imaging Challenge Dataset have demonstrated the superiority of our method.

Create account to get full access

or

If you already have an account, we'll log you in

Overview

  • Researchers have developed methods to reconstruct high-quality positron emission tomography (PET) scans from low-dose PET images, reducing radiation exposure.
  • Most current methods only learn the mapping between single-dose-level low-dose PET (LPET) and standard-dose PET (SPET) images, ignoring the dose disparity in clinical scenarios.
  • This paper proposes a novel two-phase multi-dose-level PET reconstruction algorithm that incorporates dose level awareness to generate high-quality SPET images from multi-dose-level LPET images.

Plain English Explanation

PET scans are a valuable medical imaging technique, but they expose patients to radiation. To reduce this exposure, researchers have developed methods to reconstruct high-quality PET scans from low-dose PET images. However, most of these methods only focus on learning the relationship between single-dose-level low-dose PET (LPET) and standard-dose PET (SPET) images, without considering the varying dose levels that can occur in real-world clinical settings.

To address this limitation, the researchers in this paper have designed a new two-phase algorithm that can generate high-quality SPET images from multi-dose-level LPET images. The first phase, called pre-training, is designed to extract both detailed features and effective semantic representations from the LPET images. The second phase, SPET prediction, then uses this pre-learned knowledge to first produce a preliminary high-quality SPET image and then refine it to preserve important details.

The researchers tested their method on a challenging dataset from a PET imaging competition and found that it outperformed other approaches. This suggests that their algorithm could be a valuable tool for obtaining high-quality PET scans while minimizing radiation exposure for patients.

Technical Explanation

The researchers designed a novel two-phase multi-dose-level PET reconstruction algorithm to generate high-quality standard-dose PET (SPET) images from multi-dose-level low-dose PET (LPET) images. The first phase, pre-training, aims to explore both fine-grained discriminative features and effective semantic representation from the LPET images. This involves training separate networks to learn these different aspects of the data.

The second phase, SPET prediction, then adopts a coarse prediction network that utilizes the pre-learned dose level prior to generate a preliminary high-quality SPET result. This is followed by a refinement network that precisely preserves important details in the final SPET image.

Experiments on the challenging MICCAI 2022 Ultra-low Dose PET Imaging Challenge Dataset demonstrated the superiority of this approach compared to other methods. The two-phase design with dose level awareness appears to be an effective strategy for reconstructing high-quality PET scans from low-dose inputs, which could lead to reduced radiation exposure for patients.

Critical Analysis

The paper presents a compelling approach to the important problem of generating high-quality PET scans while minimizing radiation dose. The two-phase architecture with pre-training and refinement stages seems well-designed to leverage dose level information and preserve critical details in the final SPET reconstruction.

However, the paper does not provide extensive discussion of the limitations or potential issues with the proposed method. For example, it would be helpful to know how the performance of this algorithm scales with increasing differences in dose levels between the LPET and target SPET images. Additionally, the researchers could have delved deeper into potential biases or errors that may arise from the dose level priors used in the prediction phase.

Further research and analysis in these areas could help strengthen the claims and generalizability of the approach. Nonetheless, this work represents an important step forward in revolutionizing disease diagnosis with simultaneous functional PET/MR, multi-task magnetic resonance imaging reconstruction, and other medical imaging applications that leverage deep learning for phase recovery and joint diagnosis from clinical and visual data.

Conclusion

This paper presents a novel two-phase multi-dose-level PET reconstruction algorithm that can generate high-quality standard-dose PET (SPET) images from low-dose PET (LPET) inputs, while accounting for the varying dose levels that occur in clinical settings. By incorporating dose level awareness in both the pre-training and prediction stages, the researchers were able to outperform other methods on a challenging PET imaging dataset.

This work demonstrates the potential to reduce radiation exposure for patients undergoing PET scans, while still obtaining the high-quality diagnostic information that these scans provide. Further research to address potential limitations and expand the generalizability of this approach could lead to significant improvements in medical imaging and multi-level label correction for disease diagnosis.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Related Papers

Dose-aware Diffusion Model for 3D Low-dose PET: Multi-institutional Validation with Reader Study and Real Low-dose Data

Dose-aware Diffusion Model for 3D Low-dose PET: Multi-institutional Validation with Reader Study and Real Low-dose Data

Huidong Xie, Weijie Gan, Bo Zhou, Ming-Kai Chen, Michal Kulon, Annemarie Boustani, Benjamin A. Spencer, Reimund Bayerlein, Xiongchao Chen, Qiong Liu, Xueqi Guo, Menghua Xia, Yinchi Zhou, Hui Liu, Liang Guo, Hongyu An, Ulugbek S. Kamilov, Hanzhong Wang, Biao Li, Axel Rominger, Kuangyu Shi, Ge Wang, Ramsey D. Badawi, Chi Liu

YC

0

Reddit

0

As PET imaging is accompanied by radiation exposure and potentially increased cancer risk, reducing radiation dose in PET scans without compromising the image quality is an important topic. Deep learning (DL) techniques have been investigated for low-dose PET imaging. However, existing models have often resulted in compromised image quality when achieving low-dose PET and have limited generalizability to different image noise-levels, acquisition protocols, patient populations, and hospitals. Recently, diffusion models have emerged as the new state-of-the-art generative model to generate high-quality samples and have demonstrated strong potential for medical imaging tasks. However, for low-dose PET imaging, existing diffusion models failed to generate consistent 3D reconstructions, unable to generalize across varying noise-levels, often produced visually-appealing but distorted image details, and produced images with biased tracer uptake. Here, we develop DDPET-3D, a dose-aware diffusion model for 3D low-dose PET imaging to address these challenges. Collected from 4 medical centers globally with different scanners and clinical protocols, we extensively evaluated the proposed model using a total of 9,783 18F-FDG studies (1,596 patients) with low-dose/low-count levels ranging from 1% to 50%. With a cross-center, cross-scanner validation, the proposed DDPET-3D demonstrated its potential to generalize to different low-dose levels, different scanners, and different clinical protocols. As confirmed with reader studies performed by nuclear medicine physicians, the proposed method produced superior denoised results that are comparable to or even better than the 100% full-count images as well as previous DL baselines. The presented results show the potential of achieving low-dose PET while maintaining image quality. Lastly, a group of real low-dose scans was also included for evaluation.

Read more

5/24/2024

📈

Full-dose Whole-body PET Synthesis from Low-dose PET Using High-efficiency Denoising Diffusion Probabilistic Model: PET Consistency Model

Shaoyan Pan, Elham Abouei, Junbo Peng, Joshua Qian, Jacob F Wynne, Tonghe Wang, Chih-Wei Chang, Justin Roper, Jonathon A Nye, Hui Mao, Xiaofeng Yang

YC

0

Reddit

0

Objective: Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes with high radiation exposure. Improving image quality is desirable for all clinical applications while minimizing radiation exposure is needed to reduce risk to patients. Approach: We introduce PET Consistency Model (PET-CM), an efficient diffusion-based method for generating high-quality full-dose PET images from low-dose PET images. It employs a two-step process, adding Gaussian noise to full-dose PET images in the forward diffusion, and then denoising them using a PET Shifted-window Vision Transformer (PET-VIT) network in the reverse diffusion. The PET-VIT network learns a consistency function that enables direct denoising of Gaussian noise into clean full-dose PET images. PET-CM achieves state-of-the-art image quality while requiring significantly less computation time than other methods. Results: In experiments comparing eighth-dose to full-dose images, PET-CM demonstrated impressive performance with NMAE of 1.278+/-0.122%, PSNR of 33.783+/-0.824dB, SSIM of 0.964+/-0.009, NCC of 0.968+/-0.011, HRS of 4.543, and SUV Error of 0.255+/-0.318%, with an average generation time of 62 seconds per patient. This is a significant improvement compared to the state-of-the-art diffusion-based model with PET-CM reaching this result 12x faster. Similarly, in the quarter-dose to full-dose image experiments, PET-CM delivered competitive outcomes, achieving an NMAE of 0.973+/-0.066%, PSNR of 36.172+/-0.801dB, SSIM of 0.984+/-0.004, NCC of 0.990+/-0.005, HRS of 4.428, and SUV Error of 0.151+/-0.192% using the same generation process, which underlining its high quantitative and clinical precision in both denoising scenario.

Read more

4/10/2024

📈

MCAD: Multi-modal Conditioned Adversarial Diffusion Model for High-Quality PET Image Reconstruction

Jiaqi Cui, Xinyi Zeng, Pinxian Zeng, Bo Liu, Xi Wu, Jiliu Zhou, Yan Wang

YC

0

Reddit

0

Radiation hazards associated with standard-dose positron emission tomography (SPET) images remain a concern, whereas the quality of low-dose PET (LPET) images fails to meet clinical requirements. Therefore, there is great interest in reconstructing SPET images from LPET images. However, prior studies focus solely on image data, neglecting vital complementary information from other modalities, e.g., patients' clinical tabular, resulting in compromised reconstruction with limited diagnostic utility. Moreover, they often overlook the semantic consistency between real SPET and reconstructed images, leading to distorted semantic contexts. To tackle these problems, we propose a novel Multi-modal Conditioned Adversarial Diffusion model (MCAD) to reconstruct SPET images from multi-modal inputs, including LPET images and clinical tabular. Specifically, our MCAD incorporates a Multi-modal conditional Encoder (Mc-Encoder) to extract multi-modal features, followed by a conditional diffusion process to blend noise with multi-modal features and gradually map blended features to the target SPET images. To balance multi-modal inputs, the Mc-Encoder embeds Optimal Multi-modal Transport co-Attention (OMTA) to narrow the heterogeneity gap between image and tabular while capturing their interactions, providing sufficient guidance for reconstruction. In addition, to mitigate semantic distortions, we introduce the Multi-Modal Masked Text Reconstruction (M3TRec), which leverages semantic knowledge extracted from denoised PET images to restore the masked clinical tabular, thereby compelling the network to maintain accurate semantics during reconstruction. To expedite the diffusion process, we further introduce an adversarial diffusive network with a reduced number of diffusion steps. Experiments show that our method achieves the state-of-the-art performance both qualitatively and quantitatively.

Read more

6/21/2024

Low-Dose CT Reconstruction Using Dataset-free Learning

Low-Dose CT Reconstruction Using Dataset-free Learning

Feng Wang, Renfang Wang, Hong Qiu

YC

0

Reddit

0

Low-Dose computer tomography (LDCT) is an ideal alternative to reduce radiation risk in clinical applications. Although supervised-deep-learning-based reconstruction methods have demonstrated superior performance compared to conventional model-driven reconstruction algorithms, they require collecting massive pairs of low-dose and norm-dose CT images for neural network training, which limits their practical application in LDCT imaging. In this paper, we propose an unsupervised and training data-free learning reconstruction method for LDCT imaging that avoids the requirement for training data. The proposed method is a post-processing technique that aims to enhance the initial low-quality reconstruction results, and it reconstructs the high-quality images by neural work training that minimizes the $ell_1$-norm distance between the CT measurements and their corresponding simulated sinogram data, as well as the total variation (TV) value of the reconstructed image. Moreover, the proposed method does not require to set the weights for both the data fidelity term and the plenty term. Experimental results on the AAPM challenge data and LoDoPab-CT data demonstrate that the proposed method is able to effectively suppress the noise and preserve the tiny structures. Also, these results demonstrate the rapid convergence and low computational cost of the proposed method. The source code is available at url{https://github.com/linfengyu77/IRLDCT}.

Read more

5/24/2024