Full-dose Whole-body PET Synthesis from Low-dose PET Using High-efficiency Denoising Diffusion Probabilistic Model: PET Consistency Model

2308.13072

YC

0

Reddit

0

Published 4/10/2024 by Shaoyan Pan, Elham Abouei, Junbo Peng, Joshua Qian, Jacob F Wynne, Tonghe Wang, Chih-Wei Chang, Justin Roper, Jonathon A Nye, Hui Mao and 1 other

📈

Abstract

Objective: Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes with high radiation exposure. Improving image quality is desirable for all clinical applications while minimizing radiation exposure is needed to reduce risk to patients. Approach: We introduce PET Consistency Model (PET-CM), an efficient diffusion-based method for generating high-quality full-dose PET images from low-dose PET images. It employs a two-step process, adding Gaussian noise to full-dose PET images in the forward diffusion, and then denoising them using a PET Shifted-window Vision Transformer (PET-VIT) network in the reverse diffusion. The PET-VIT network learns a consistency function that enables direct denoising of Gaussian noise into clean full-dose PET images. PET-CM achieves state-of-the-art image quality while requiring significantly less computation time than other methods. Results: In experiments comparing eighth-dose to full-dose images, PET-CM demonstrated impressive performance with NMAE of 1.278+/-0.122%, PSNR of 33.783+/-0.824dB, SSIM of 0.964+/-0.009, NCC of 0.968+/-0.011, HRS of 4.543, and SUV Error of 0.255+/-0.318%, with an average generation time of 62 seconds per patient. This is a significant improvement compared to the state-of-the-art diffusion-based model with PET-CM reaching this result 12x faster. Similarly, in the quarter-dose to full-dose image experiments, PET-CM delivered competitive outcomes, achieving an NMAE of 0.973+/-0.066%, PSNR of 36.172+/-0.801dB, SSIM of 0.984+/-0.004, NCC of 0.990+/-0.005, HRS of 4.428, and SUV Error of 0.151+/-0.192% using the same generation process, which underlining its high quantitative and clinical precision in both denoising scenario.

Create account to get full access

or

If you already have an account, we'll log you in

Overview

  • Positron Emission Tomography (PET) is a widely used medical imaging technique, but there is a tradeoff between image quality and radiation exposure to patients.
  • The paper introduces a method called PET Consistency Model (PET-CM) that can generate high-quality PET images from low-dose PET scans, reducing radiation exposure while maintaining image quality.
  • PET-CM uses a two-step process involving adding noise to full-dose PET images and then denoising them using a specialized PET Shifted-window Vision Transformer (PET-VIT) network.

Plain English Explanation

PET scans are a valuable medical tool, but they expose patients to radiation. Researchers have developed a new method called PET-CM that can generate high-quality PET images from lower-dose scans, reducing radiation exposure. PET-CM works by first adding some artificial noise to full-dose PET images, and then using a specialized neural network to remove that noise and reconstruct the original high-quality image. This allows doctors to get the information they need from PET scans while keeping radiation doses low, which is important for patient safety.

Technical Explanation

The paper presents the PET Consistency Model (PET-CM), an efficient diffusion-based approach for generating high-quality full-dose PET images from low-dose PET scans. PET-CM employs a two-step process:

  1. Adding Gaussian noise to full-dose PET images in the forward diffusion step.
  2. Denoising the noisy images using a PET Shifted-window Vision Transformer (PET-VIT) network in the reverse diffusion step.

The PET-VIT network learns a consistency function that enables direct denoising of the Gaussian noise, reconstructing the original full-dose PET image. Compared to other state-of-the-art diffusion-based methods, PET-CM achieves superior image quality while requiring significantly less computation time.

In experiments, PET-CM demonstrated impressive performance when generating full-dose PET images from eighth-dose and quarter-dose scans. For the eighth-dose case, it achieved:

  • NMAE of 1.278 ± 0.122%
  • PSNR of 33.783 ± 0.824 dB
  • SSIM of 0.964 ± 0.009
  • NCC of 0.968 ± 0.011
  • HRS of 4.543
  • SUV Error of 0.255 ± 0.318%

This was achieved with an average generation time of just 62 seconds per patient, 12x faster than the previous state-of-the-art diffusion-based model.

Critical Analysis

The paper provides a comprehensive technical explanation of the PET-CM method and demonstrates its effectiveness through extensive experiments. However, a few potential limitations are worth considering:

  • The paper does not discuss the impact of PET-CM on clinical decision-making or patient outcomes. While the quantitative metrics are impressive, it would be valuable to understand how these improvements translate to real-world clinical applications.
  • The experiments focus on generating full-dose PET images from low-dose scans, but the authors do not explore the potential trade-offs or challenges that may arise when using PET-CM in a clinical setting with different radiation dose levels or patient populations.
  • The paper does not address potential issues with the PET-VIT network or discuss how it compares to other denoising approaches beyond the diffusion-based models mentioned.

Overall, the PET-CM method shows promise, but further research is needed to fully understand its practical implications and limitations in clinical settings.

Conclusion

The PET Consistency Model (PET-CM) introduced in this paper is a significant advancement in the field of PET imaging. By leveraging a specialized neural network to denoise low-dose PET scans, PET-CM can generate high-quality PET images while substantially reducing radiation exposure for patients. This has the potential to improve the safety and accessibility of PET imaging, benefiting a wide range of clinical applications. As the authors continue to refine and validate the method, PET-CM could become an important tool for balancing image quality and patient safety in medical imaging.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Related Papers

Dose-aware Diffusion Model for 3D Low-dose PET: Multi-institutional Validation with Reader Study and Real Low-dose Data

Dose-aware Diffusion Model for 3D Low-dose PET: Multi-institutional Validation with Reader Study and Real Low-dose Data

Huidong Xie, Weijie Gan, Bo Zhou, Ming-Kai Chen, Michal Kulon, Annemarie Boustani, Benjamin A. Spencer, Reimund Bayerlein, Xiongchao Chen, Qiong Liu, Xueqi Guo, Menghua Xia, Yinchi Zhou, Hui Liu, Liang Guo, Hongyu An, Ulugbek S. Kamilov, Hanzhong Wang, Biao Li, Axel Rominger, Kuangyu Shi, Ge Wang, Ramsey D. Badawi, Chi Liu

YC

0

Reddit

0

As PET imaging is accompanied by radiation exposure and potentially increased cancer risk, reducing radiation dose in PET scans without compromising the image quality is an important topic. Deep learning (DL) techniques have been investigated for low-dose PET imaging. However, existing models have often resulted in compromised image quality when achieving low-dose PET and have limited generalizability to different image noise-levels, acquisition protocols, patient populations, and hospitals. Recently, diffusion models have emerged as the new state-of-the-art generative model to generate high-quality samples and have demonstrated strong potential for medical imaging tasks. However, for low-dose PET imaging, existing diffusion models failed to generate consistent 3D reconstructions, unable to generalize across varying noise-levels, often produced visually-appealing but distorted image details, and produced images with biased tracer uptake. Here, we develop DDPET-3D, a dose-aware diffusion model for 3D low-dose PET imaging to address these challenges. Collected from 4 medical centers globally with different scanners and clinical protocols, we extensively evaluated the proposed model using a total of 9,783 18F-FDG studies (1,596 patients) with low-dose/low-count levels ranging from 1% to 50%. With a cross-center, cross-scanner validation, the proposed DDPET-3D demonstrated its potential to generalize to different low-dose levels, different scanners, and different clinical protocols. As confirmed with reader studies performed by nuclear medicine physicians, the proposed method produced superior denoised results that are comparable to or even better than the 100% full-count images as well as previous DL baselines. The presented results show the potential of achieving low-dose PET while maintaining image quality. Lastly, a group of real low-dose scans was also included for evaluation.

Read more

5/24/2024

🤿

LpQcM: Adaptable Lesion-Quantification-Consistent Modulation for Deep Learning Low-Count PET Image Denoising

Menghua Xia, Huidong Xie, Qiong Liu, Bo Zhou, Hanzhong Wang, Biao Li, Axel Rominger, Kuangyu Shi, Georges EI Fakhri, Chi Liu

YC

0

Reddit

0

Deep learning-based positron emission tomography (PET) image denoising offers the potential to reduce radiation exposure and scanning time by transforming low-count images into high-count equivalents. However, existing methods typically blur crucial details, leading to inaccurate lesion quantification. This paper proposes a lesion-perceived and quantification-consistent modulation (LpQcM) strategy for enhanced PET image denoising, via employing downstream lesion quantification analysis as auxiliary tools. The LpQcM is a plug-and-play design adaptable to a wide range of model architectures, modulating the sampling and optimization procedures of model training without adding any computational burden to the inference phase. Specifically, the LpQcM consists of two components, the lesion-perceived modulation (LpM) and the multiscale quantification-consistent modulation (QcM). The LpM enhances lesion contrast and visibility by allocating higher sampling weights and stricter loss criteria to lesion-present samples determined by an auxiliary segmentation network than lesion-absent ones. The QcM further emphasizes accuracy of quantification for both the mean and maximum standardized uptake value (SUVmean and SUVmax) across multiscale sub-regions throughout the entire image, thereby enhancing the overall image quality. Experiments conducted on large PET datasets from multiple centers and vendors, and varying noise levels demonstrated the LpQcM efficacy across various denoising frameworks. Compared to frameworks without LpQcM, the integration of LpQcM reduces the lesion SUVmean bias by 2.92% on average and increases the peak signal-to-noise ratio (PSNR) by 0.34 on average, for denoising images of extremely low-count levels below 10%.

Read more

4/30/2024

2.5D Multi-view Averaging Diffusion Model for 3D Medical Image Translation: Application to Low-count PET Reconstruction with CT-less Attenuation Correction

2.5D Multi-view Averaging Diffusion Model for 3D Medical Image Translation: Application to Low-count PET Reconstruction with CT-less Attenuation Correction

Tianqi Chen, Jun Hou, Yinchi Zhou, Huidong Xie, Xiongchao Chen, Qiong Liu, Xueqi Guo, Menghua Xia, James S. Duncan, Chi Liu, Bo Zhou

YC

0

Reddit

0

Positron Emission Tomography (PET) is an important clinical imaging tool but inevitably introduces radiation hazards to patients and healthcare providers. Reducing the tracer injection dose and eliminating the CT acquisition for attenuation correction can reduce the overall radiation dose, but often results in PET with high noise and bias. Thus, it is desirable to develop 3D methods to translate the non-attenuation-corrected low-dose PET (NAC-LDPET) into attenuation-corrected standard-dose PET (AC-SDPET). Recently, diffusion models have emerged as a new state-of-the-art deep learning method for image-to-image translation, better than traditional CNN-based methods. However, due to the high computation cost and memory burden, it is largely limited to 2D applications. To address these challenges, we developed a novel 2.5D Multi-view Averaging Diffusion Model (MADM) for 3D image-to-image translation with application on NAC-LDPET to AC-SDPET translation. Specifically, MADM employs separate diffusion models for axial, coronal, and sagittal views, whose outputs are averaged in each sampling step to ensure the 3D generation quality from multiple views. To accelerate the 3D sampling process, we also proposed a strategy to use the CNN-based 3D generation as a prior for the diffusion model. Our experimental results on human patient studies suggested that MADM can generate high-quality 3D translation images, outperforming previous CNN-based and Diffusion-based baseline methods.

Read more

6/18/2024

🖼️

Two-Phase Multi-Dose-Level PET Image Reconstruction with Dose Level Awareness

Yuchen Fei, Yanmei Luo, Yan Wang, Jiaqi Cui, Yuanyuan Xu, Jiliu Zhou, Dinggang Shen

YC

0

Reddit

0

To obtain high-quality positron emission tomography (PET) while minimizing radiation exposure, a range of methods have been designed to reconstruct standard-dose PET (SPET) from corresponding low-dose PET (LPET) images. However, most current methods merely learn the mapping between single-dose-level LPET and SPET images, but omit the dose disparity of LPET images in clinical scenarios. In this paper, to reconstruct high-quality SPET images from multi-dose-level LPET images, we design a novel two-phase multi-dose-level PET reconstruction algorithm with dose level awareness, containing a pre-training phase and a SPET prediction phase. Specifically, the pre-training phase is devised to explore both fine-grained discriminative features and effective semantic representation. The SPET prediction phase adopts a coarse prediction network utilizing pre-learned dose level prior to generate preliminary result, and a refinement network to precisely preserve the details. Experiments on MICCAI 2022 Ultra-low Dose PET Imaging Challenge Dataset have demonstrated the superiority of our method.

Read more

4/11/2024