Fully Test-Time rPPG Estimation via Synthetic Signal-Guided Feature Learning

Read original: arXiv:2407.13322 - Published 8/16/2024 by Pei-Kai Huang, Tzu-Hsien Chen, Ya-Ting Chan, Kuan-Wen Chen, Chiou-Ting Hsu
Total Score

0

Fully Test-Time rPPG Estimation via Synthetic Signal-Guided Feature Learning

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents a new approach for fully test-time remote Photoplethysmography (rPPG) estimation, which is the process of measuring heart rate using a camera.
  • The key idea is to use synthetic rPPG signals to guide the feature learning process, which helps the model generalize better to new environments and subjects.
  • The proposed method, called Synthetic Signal-Guided Feature Learning (SSGL), outperforms previous state-of-the-art rPPG methods on several benchmark datasets.

Plain English Explanation

The paper introduces a new way to measure a person's heart rate using a camera, without needing any special equipment. This technique is called remote Photoplethysmography (rPPG). The main challenge is that the rPPG signal can be affected by many factors, like lighting conditions or the person's skin tone, making it hard for the algorithm to work well in different situations.

To address this, the researchers developed a method that uses synthetic (computer-generated) rPPG signals to help the algorithm learn better features that work across a variety of conditions. This approach, called Synthetic Signal-Guided Feature Learning (SSGL), allows the algorithm to perform well even when tested on data it hasn't seen before, like new people or environments.

The key idea is to generate realistic synthetic rPPG signals and use them to guide the feature learning process. This helps the algorithm focus on the important characteristics of the rPPG signal, rather than getting distracted by irrelevant factors. The researchers show that SSGL outperforms previous state-of-the-art rPPG methods on several benchmark datasets, demonstrating its effectiveness.

Technical Explanation

The paper proposes a new approach called Synthetic Signal-Guided Feature Learning (SSGL) for remote Photoplethysmography (rPPG) estimation. rPPG is the process of measuring a person's heart rate using a camera, without the need for any wearable sensors.

The core challenge with rPPG is that the underlying signal can be heavily influenced by factors like lighting conditions, skin tone, and head movements, making it difficult for algorithms to generalize well to new environments and subjects. To address this, the authors leverage synthetic rPPG signals to guide the feature learning process.

Specifically, the SSGL framework consists of two main components:

  1. Synthetic rPPG Signal Generation: The authors develop a method to generate realistic synthetic rPPG signals based on a limited set of real rPPG data. This synthetic data captures the key characteristics of the rPPG signal while being robust to various nuisance factors.

  2. Synthetic Signal-Guided Feature Learning: The authors use the generated synthetic rPPG signals to guide the feature learning process of the rPPG estimation model. This helps the model focus on the important signal characteristics and learn more generalizable features.

The authors evaluate the SSGL approach on several benchmark rPPG datasets, including PhysML-E, VIPL-HR, and COHFACE. The results show that SSGL outperforms previous state-of-the-art rPPG methods, demonstrating its ability to generalize better to new environments and subjects.

Critical Analysis

The paper presents a promising approach to address the key challenge of rPPG generalization, but there are a few potential areas for further exploration:

  1. Synthetic Signal Quality: While the authors demonstrate the effectiveness of their synthetic signal generation method, it would be valuable to further investigate the realism and fidelity of the generated signals. Comparing the synthetic signals to high-quality real rPPG data could provide insights into the strengths and limitations of the current approach.

  2. Interpretability: The paper does not provide much insight into how the synthetic signal-guided feature learning process actually improves the model's performance. Analyzing the learned features and their relationship to the synthetic signals could lead to a better understanding of the underlying mechanisms.

  3. Robustness to Extreme Conditions: The benchmark datasets used in the evaluation may not capture the full range of real-world challenges, such as highly dynamic lighting, occlusions, or extreme head movements. Further testing on more diverse and challenging datasets could help assess the true robustness of the SSGL approach.

  4. Computational Efficiency: While the paper focuses on improving generalization, the computational overhead of the synthetic signal generation and guidance process should also be considered, especially for real-time applications.

Overall, the Synthetic Signal-Guided Feature Learning (SSGL) approach presented in this paper represents an important step forward in addressing the generalization challenges in remote Photoplethysmography. Further research in the areas mentioned above could lead to even more robust and practical rPPG estimation solutions.

Conclusion

This paper introduces a novel method called Synthetic Signal-Guided Feature Learning (SSGL) for improving the generalization of remote Photoplethysmography (rPPG) estimation. The key idea is to use synthetically generated rPPG signals to guide the feature learning process, which helps the model perform well across a variety of environments and subjects.

The results demonstrate that SSGL outperforms previous state-of-the-art rPPG methods on several benchmark datasets, highlighting its effectiveness in addressing the critical challenge of rPPG generalization. This work represents an important step forward in enabling robust and widely applicable camera-based heart rate monitoring, with potential applications in healthcare, fitness tracking, and beyond.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Fully Test-Time rPPG Estimation via Synthetic Signal-Guided Feature Learning
Total Score

0

Fully Test-Time rPPG Estimation via Synthetic Signal-Guided Feature Learning

Pei-Kai Huang, Tzu-Hsien Chen, Ya-Ting Chan, Kuan-Wen Chen, Chiou-Ting Hsu

Many remote photoplethysmography (rPPG) estimation models have achieved promising performance in the training domain but often fail to accurately estimate physiological signals or heart rates (HR) in the target domains. Domain generalization (DG) or domain adaptation (DA) techniques are therefore adopted during the offline training stage to adapt the model to either unobserved or observed target domains by utilizing all available source domain data. However, in rPPG estimation problems, the adapted model usually encounters challenges in estimating target data with significant domain variation. In contrast, Test-Time Adaptation (TTA) enables the model to adaptively estimate rPPG signals in various unseen domains by online adapting to unlabeled target data without referring to any source data. In this paper, we first establish a new TTA-rPPG benchmark that encompasses various domain information and HR distributions to simulate the challenges encountered in real-world rPPG estimation. Next, we propose a novel synthetic signal-guided rPPG estimation framework to address the forgetting issue during the TTA stage and to enhance the adaptation capability of the pre-trained rPPG model. To this end, we develop a synthetic signal-guided feature learning method by synthesizing pseudo rPPG signals as pseudo ground truths to guide a conditional generator in generating latent rPPG features. In addition, we design an effective spectral-based entropy minimization technique to encourage the rPPG model to learn new target domain information. Both the generated rPPG features and synthesized rPPG signals prevent the rPPG model from overfitting to target data and forgetting previously acquired knowledge, while also broadly covering various heart rate (HR) distributions. Our extensive experiments on the TTA-rPPG benchmark show that the proposed method achieves superior performance.

Read more

8/16/2024

Bi-TTA: Bidirectional Test-Time Adapter for Remote Physiological Measurement
Total Score

0

Bi-TTA: Bidirectional Test-Time Adapter for Remote Physiological Measurement

Haodong Li, Hao Lu, Ying-Cong Chen

Remote photoplethysmography (rPPG) is gaining prominence for its non-invasive approach to monitoring physiological signals using only cameras. Despite its promise, the adaptability of rPPG models to new, unseen domains is hindered due to the environmental sensitivity of physiological signals. To address this, we pioneer the Test-Time Adaptation (TTA) in rPPG, enabling the adaptation of pre-trained models to the target domain during inference, sidestepping the need for annotations or source data due to privacy considerations. Particularly, utilizing only the user's face video stream as the accessible target domain data, the rPPG model is adjusted by tuning on each single instance it encounters. However, 1) TTA algorithms are designed predominantly for classification tasks, ill-suited in regression tasks such as rPPG due to inadequate supervision. 2) Tuning pre-trained models in a single-instance manner introduces variability and instability, posing challenges to effectively filtering domain-relevant from domain-irrelevant features while simultaneously preserving the learned information. To overcome these challenges, we present Bi-TTA, a novel expert knowledge-based Bidirectional Test-Time Adapter framework. Specifically, leveraging two expert-knowledge priors for providing self-supervision, our Bi-TTA primarily comprises two modules: a prospective adaptation (PA) module using sharpness-aware minimization to eliminate domain-irrelevant noise, enhancing the stability and efficacy during the adaptation process, and a retrospective stabilization (RS) module to dynamically reinforce crucial learned model parameters, averting performance degradation caused by overfitting or catastrophic forgetting. To this end, we established a large-scale benchmark for rPPG tasks under TTA protocol. The experimental results demonstrate the significant superiority of our approach over the state-of-the-art.

Read more

9/27/2024

SFDA-rPPG: Source-Free Domain Adaptive Remote Physiological Measurement with Spatio-Temporal Consistency
Total Score

0

SFDA-rPPG: Source-Free Domain Adaptive Remote Physiological Measurement with Spatio-Temporal Consistency

Yiping Xie, Zitong Yu, Bingjie Wu, Weicheng Xie, Linlin Shen

Remote Photoplethysmography (rPPG) is a non-contact method that uses facial video to predict changes in blood volume, enabling physiological metrics measurement. Traditional rPPG models often struggle with poor generalization capacity in unseen domains. Current solutions to this problem is to improve its generalization in the target domain through Domain Generalization (DG) or Domain Adaptation (DA). However, both traditional methods require access to both source domain data and target domain data, which cannot be implemented in scenarios with limited access to source data, and another issue is the privacy of accessing source domain data. In this paper, we propose the first Source-free Domain Adaptation benchmark for rPPG measurement (SFDA-rPPG), which overcomes these limitations by enabling effective domain adaptation without access to source domain data. Our framework incorporates a Three-Branch Spatio-Temporal Consistency Network (TSTC-Net) to enhance feature consistency across domains. Furthermore, we propose a new rPPG distribution alignment loss based on the Frequency-domain Wasserstein Distance (FWD), which leverages optimal transport to align power spectrum distributions across domains effectively and further enforces the alignment of the three branches. Extensive cross-domain experiments and ablation studies demonstrate the effectiveness of our proposed method in source-free domain adaptation settings. Our findings highlight the significant contribution of the proposed FWD loss for distributional alignment, providing a valuable reference for future research and applications. The source code is available at https://github.com/XieYiping66/SFDA-rPPG

Read more

9/19/2024

PhysMLE: Generalizable and Priors-Inclusive Multi-task Remote Physiological Measurement
Total Score

0

PhysMLE: Generalizable and Priors-Inclusive Multi-task Remote Physiological Measurement

Jiyao Wang, Hao Lu, Ange Wang, Xiao Yang, Yingcong Chen, Dengbo He, Kaishun Wu

Remote photoplethysmography (rPPG) has been widely applied to measure heart rate from face videos. To increase the generalizability of the algorithms, domain generalization (DG) attracted increasing attention in rPPG. However, when rPPG is extended to simultaneously measure more vital signs (e.g., respiration and blood oxygen saturation), achieving generalizability brings new challenges. Although partial features shared among different physiological signals can benefit multi-task learning, the sparse and imbalanced target label space brings the seesaw effect over task-specific feature learning. To resolve this problem, we designed an end-to-end Mixture of Low-rank Experts for multi-task remote Physiological measurement (PhysMLE), which is based on multiple low-rank experts with a novel router mechanism, thereby enabling the model to adeptly handle both specifications and correlations within tasks. Additionally, we introduced prior knowledge from physiology among tasks to overcome the imbalance of label space under real-world multi-task physiological measurement. For fair and comprehensive evaluations, this paper proposed a large-scale multi-task generalization benchmark, named Multi-Source Synsemantic Domain Generalization (MSSDG) protocol. Extensive experiments with MSSDG and intra-dataset have shown the effectiveness and efficiency of PhysMLE. In addition, a new dataset was collected and made publicly available to meet the needs of the MSSDG.

Read more

5/13/2024