SFDA-rPPG: Source-Free Domain Adaptive Remote Physiological Measurement with Spatio-Temporal Consistency

Read original: arXiv:2409.12040 - Published 9/19/2024 by Yiping Xie, Zitong Yu, Bingjie Wu, Weicheng Xie, Linlin Shen
Total Score

0

SFDA-rPPG: Source-Free Domain Adaptive Remote Physiological Measurement with Spatio-Temporal Consistency

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • SFDA-rPPG is a research paper that explores a method for remote physiological measurement that can adapt to different domains without requiring access to the original training data.
  • The paper proposes a "source-free domain adaptive" approach to remote photoplethysmography (rPPG), which can measure vital signs like heart rate from video footage.
  • The key innovation is maintaining spatio-temporal consistency to enable domain adaptation without the original training data.

Plain English Explanation

The paper discusses a new technique for measuring physiological signals like heart rate from video footage, even when the video is recorded in a different setting than the one the system was originally trained on. This is an important problem because video-based physiological measurement can be very useful for remote health monitoring, but the performance often degrades when the system is used in a new environment.

The researchers developed a "source-free domain adaptive" approach, which means the system can adapt to a new environment without needing access to the original training data. This is achieved by maintaining "spatio-temporal consistency" - ensuring that the measurements made from different parts of the video frame over time are coherent and make sense together. By preserving this consistency, the system can learn to work in a new setting without retraining on data from that setting.

The key innovation is this idea of spatio-temporal consistency, which allows the system to generalize to new environments in a way that previous physiological measurement approaches could not. This could make video-based health monitoring more practical and accessible for a wider range of applications.

Technical Explanation

The SFDA-rPPG model uses a convolutional neural network to extract spatio-temporal features from video frames. These features are then used to estimate physiological signals like heart rate.

The key aspect of the approach is that it uses "source-free domain adaptation" to enable the model to work in new environments without requiring access to the original training data. This is achieved through two main components:

  1. Spatial Consistency Module: This module ensures that the extracted features are spatially consistent, meaning the measurements from different regions of the video frame are coherent.

  2. Temporal Consistency Module: This module maintains temporal consistency, ensuring the extracted features change smoothly over time in a physiologically plausible way.

By preserving this spatio-temporal consistency, the model can adapt to a new domain without needing to be retrained on data from that domain. The authors demonstrate the effectiveness of this approach through experiments on multiple physiological measurement datasets.

Critical Analysis

The SFDA-rPPG paper presents a novel and promising approach to enable video-based physiological measurement systems to generalize to new environments. The emphasis on maintaining spatio-temporal consistency is a key contribution that differentiates this work from prior domain adaptation techniques for rPPG.

However, the paper does not deeply explore the limitations of the proposed method. For example, it is unclear how well the approach would handle significant changes in lighting, camera positioning, or subject demographics between the source and target domains. Further research would be needed to fully understand the robustness and generalization capabilities of the SFDA-rPPG model.

Additionally, the paper focuses primarily on the technical details of the model architecture and training procedure, with less discussion of the real-world implications and potential applications of this technology. Exploring how this work could enable new remote health monitoring use cases would strengthen the overall impact and significance of the research.

Conclusion

The SFDA-rPPG paper presents an innovative approach to enable video-based physiological measurement systems to adapt to new environments without requiring access to the original training data. By preserving spatio-temporal consistency, the model can generalize in a way that previous methods could not.

This work has the potential to make remote health monitoring more practical and accessible, as it can reduce the burden of data collection and model retraining when deploying these systems in different contexts. Further research is needed to fully characterize the limitations and robustness of the approach, as well as to explore the broader societal implications of this technology.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

SFDA-rPPG: Source-Free Domain Adaptive Remote Physiological Measurement with Spatio-Temporal Consistency
Total Score

0

SFDA-rPPG: Source-Free Domain Adaptive Remote Physiological Measurement with Spatio-Temporal Consistency

Yiping Xie, Zitong Yu, Bingjie Wu, Weicheng Xie, Linlin Shen

Remote Photoplethysmography (rPPG) is a non-contact method that uses facial video to predict changes in blood volume, enabling physiological metrics measurement. Traditional rPPG models often struggle with poor generalization capacity in unseen domains. Current solutions to this problem is to improve its generalization in the target domain through Domain Generalization (DG) or Domain Adaptation (DA). However, both traditional methods require access to both source domain data and target domain data, which cannot be implemented in scenarios with limited access to source data, and another issue is the privacy of accessing source domain data. In this paper, we propose the first Source-free Domain Adaptation benchmark for rPPG measurement (SFDA-rPPG), which overcomes these limitations by enabling effective domain adaptation without access to source domain data. Our framework incorporates a Three-Branch Spatio-Temporal Consistency Network (TSTC-Net) to enhance feature consistency across domains. Furthermore, we propose a new rPPG distribution alignment loss based on the Frequency-domain Wasserstein Distance (FWD), which leverages optimal transport to align power spectrum distributions across domains effectively and further enforces the alignment of the three branches. Extensive cross-domain experiments and ablation studies demonstrate the effectiveness of our proposed method in source-free domain adaptation settings. Our findings highlight the significant contribution of the proposed FWD loss for distributional alignment, providing a valuable reference for future research and applications. The source code is available at https://github.com/XieYiping66/SFDA-rPPG

Read more

9/19/2024

Fully Test-Time rPPG Estimation via Synthetic Signal-Guided Feature Learning
Total Score

0

Fully Test-Time rPPG Estimation via Synthetic Signal-Guided Feature Learning

Pei-Kai Huang, Tzu-Hsien Chen, Ya-Ting Chan, Kuan-Wen Chen, Chiou-Ting Hsu

Many remote photoplethysmography (rPPG) estimation models have achieved promising performance in the training domain but often fail to accurately estimate physiological signals or heart rates (HR) in the target domains. Domain generalization (DG) or domain adaptation (DA) techniques are therefore adopted during the offline training stage to adapt the model to either unobserved or observed target domains by utilizing all available source domain data. However, in rPPG estimation problems, the adapted model usually encounters challenges in estimating target data with significant domain variation. In contrast, Test-Time Adaptation (TTA) enables the model to adaptively estimate rPPG signals in various unseen domains by online adapting to unlabeled target data without referring to any source data. In this paper, we first establish a new TTA-rPPG benchmark that encompasses various domain information and HR distributions to simulate the challenges encountered in real-world rPPG estimation. Next, we propose a novel synthetic signal-guided rPPG estimation framework to address the forgetting issue during the TTA stage and to enhance the adaptation capability of the pre-trained rPPG model. To this end, we develop a synthetic signal-guided feature learning method by synthesizing pseudo rPPG signals as pseudo ground truths to guide a conditional generator in generating latent rPPG features. In addition, we design an effective spectral-based entropy minimization technique to encourage the rPPG model to learn new target domain information. Both the generated rPPG features and synthesized rPPG signals prevent the rPPG model from overfitting to target data and forgetting previously acquired knowledge, while also broadly covering various heart rate (HR) distributions. Our extensive experiments on the TTA-rPPG benchmark show that the proposed method achieves superior performance.

Read more

8/16/2024

Measuring Domain Shifts using Deep Learning Remote Photoplethysmography Model Similarity
Total Score

0

Measuring Domain Shifts using Deep Learning Remote Photoplethysmography Model Similarity

Nathan Vance, Patrick Flynn

Domain shift differences between training data for deep learning models and the deployment context can result in severe performance issues for models which fail to generalize. We study the domain shift problem under the context of remote photoplethysmography (rPPG), a technique for video-based heart rate inference. We propose metrics based on model similarity which may be used as a measure of domain shift, and we demonstrate high correlation between these metrics and empirical performance. One of the proposed metrics with viable correlations, DS-diff, does not assume access to the ground truth of the target domain, i.e. it may be applied to in-the-wild data. To that end, we investigate a model selection problem in which ground truth results for the evaluation domain is not known, demonstrating a 13.9% performance improvement over the average case baseline.

Read more

4/15/2024

Bi-TTA: Bidirectional Test-Time Adapter for Remote Physiological Measurement
Total Score

0

Bi-TTA: Bidirectional Test-Time Adapter for Remote Physiological Measurement

Haodong Li, Hao Lu, Ying-Cong Chen

Remote photoplethysmography (rPPG) is gaining prominence for its non-invasive approach to monitoring physiological signals using only cameras. Despite its promise, the adaptability of rPPG models to new, unseen domains is hindered due to the environmental sensitivity of physiological signals. To address this, we pioneer the Test-Time Adaptation (TTA) in rPPG, enabling the adaptation of pre-trained models to the target domain during inference, sidestepping the need for annotations or source data due to privacy considerations. Particularly, utilizing only the user's face video stream as the accessible target domain data, the rPPG model is adjusted by tuning on each single instance it encounters. However, 1) TTA algorithms are designed predominantly for classification tasks, ill-suited in regression tasks such as rPPG due to inadequate supervision. 2) Tuning pre-trained models in a single-instance manner introduces variability and instability, posing challenges to effectively filtering domain-relevant from domain-irrelevant features while simultaneously preserving the learned information. To overcome these challenges, we present Bi-TTA, a novel expert knowledge-based Bidirectional Test-Time Adapter framework. Specifically, leveraging two expert-knowledge priors for providing self-supervision, our Bi-TTA primarily comprises two modules: a prospective adaptation (PA) module using sharpness-aware minimization to eliminate domain-irrelevant noise, enhancing the stability and efficacy during the adaptation process, and a retrospective stabilization (RS) module to dynamically reinforce crucial learned model parameters, averting performance degradation caused by overfitting or catastrophic forgetting. To this end, we established a large-scale benchmark for rPPG tasks under TTA protocol. The experimental results demonstrate the significant superiority of our approach over the state-of-the-art.

Read more

9/27/2024