Ghost imaging-based Non-contact Heart Rate Detection

Read original: arXiv:2406.02640 - Published 6/6/2024 by Jianming Yu, Yuchen He, Bin Li, Hui Chen, Huaibin Zheng, Jianbin Liu, Zhuo Xu
Total Score

0

Ghost imaging-based Non-contact Heart Rate Detection

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents a non-contact method for measuring heart rate using ghost imaging, a technique that reconstructs an image from random light patterns.
  • The proposed approach uses a single-pixel detector to capture the light reflected from a person's skin, which contains information about their heart rate.
  • The authors demonstrate the effectiveness of their method through simulations and experiments, showing it can accurately detect heart rate without requiring the person to wear any sensors.

Plain English Explanation

The paper describes a way to measure a person's heart rate without needing to attach any sensors to them. This is done using a technique called "ghost imaging," which can reconstruct an image from random patterns of light.

In this approach, a single light detector is used to capture the light reflected off the person's skin. This reflected light contains information about the person's heart rate, as the blood flow in their skin changes with each heartbeat. By analyzing the fluctuations in the reflected light, the system can determine the person's heart rate.

The authors tested their method through computer simulations and real-world experiments, and found that it could accurately measure heart rate without the person needing to wear any special equipment. This could be useful in situations where traditional heart rate monitoring methods are not practical, such as in healthcare settings or for remote monitoring applications.

Technical Explanation

The proposed method uses a ghost imaging system to non-invasively measure a person's heart rate. Ghost imaging is a technique that can reconstruct an image from the correlations between random light patterns and the total light intensity measured by a single-pixel detector.

In this case, the random light patterns are projected onto the person's skin, and the reflected light is captured by the single-pixel detector. The fluctuations in the reflected light intensity contain information about the person's heart rate, as the blood flow in their skin changes with each heartbeat.

The authors developed a signal processing algorithm to extract the heart rate information from the reflected light signal. This involved preprocessing the signal to remove noise and other artifacts, and then applying a Fast Fourier Transform to identify the dominant frequency, which corresponds to the heart rate.

The authors evaluated their method through both simulations and real-world experiments. In the simulations, they used a realistic model of the human skin and blood flow to generate the reflected light signal. In the experiments, they built a prototype ghost imaging system and tested it on human participants.

The results showed that the proposed method could accurately measure heart rate without the need for any wearable sensors or physical contact with the person. The authors compared their method to a commercial heart rate monitor and found good agreement between the two measurements.

Critical Analysis

The paper presents a novel and promising approach for non-contact heart rate monitoring using ghost imaging. However, there are a few potential limitations and areas for further research:

  1. Sensitivity to motion: The authors note that the method may be sensitive to movement or other sources of noise in the environment, which could affect the accuracy of the heart rate measurement. Further research may be needed to improve the robustness of the system to real-world conditions.

  2. Scalability: The current implementation uses a single-pixel detector, which may limit the practical application of the method. Exploring the feasibility of using a camera-based approach or multiple detectors could improve the scalability and potential use cases.

  3. Privacy concerns: While the non-contact nature of the method is a key advantage, it also raises potential privacy concerns, as the system could potentially be used for remote monitoring without the person's knowledge or consent. Addressing these ethical considerations would be important for the real-world deployment of such technology.

  4. Comparison to other methods: The paper compares the proposed method to a commercial heart rate monitor, but a more comprehensive evaluation against state-of-the-art remote heart rate monitoring techniques, such as those described in the Deep Pulse, Evaluation of Video-Based rPPG, and Uncertainty-Aware PPG-2-ECG papers, would provide a better understanding of the strengths and limitations of the ghost imaging approach.

Overall, the paper presents an innovative non-contact heart rate monitoring technique that shows promise, but further research is needed to address the identified limitations and compare it more extensively to other state-of-the-art methods.

Conclusion

The paper introduces a novel, non-contact method for measuring heart rate using ghost imaging. By capturing the light reflected from a person's skin and analyzing the fluctuations, the proposed system can accurately detect heart rate without requiring any wearable sensors or physical contact.

This approach could have significant applications in healthcare, remote monitoring, and other scenarios where traditional heart rate monitoring methods are not practical or suitable. The authors have demonstrated the feasibility of their method through both simulations and real-world experiments, and have identified some potential limitations that warrant further research.

Overall, this work represents an important step forward in the field of remote physiological measurement, and the ghost imaging technique could potentially be extended to other applications beyond heart rate monitoring in the future.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Ghost imaging-based Non-contact Heart Rate Detection
Total Score

0

Ghost imaging-based Non-contact Heart Rate Detection

Jianming Yu, Yuchen He, Bin Li, Hui Chen, Huaibin Zheng, Jianbin Liu, Zhuo Xu

Remote heart rate measurement is an increasingly concerned research field, usually using remote photoplethysmography (rPPG) to collect heart rate information through video data collection. However, in certain specific scenarios (such as low light conditions, intense lighting, and non-line-of-sight situations), traditional imaging methods fail to capture image information effectively, that may lead to difficulty or inability in measuring heart rate. To address these limitations, this study proposes using ghost imaging as a substitute for traditional imaging in the aforementioned scenarios. The mean absolute error between experimental measurements and reference true values is 4.24 bpm.Additionally, the bucket signals obtained by the ghost imaging system can be directly processed using digital signal processing techniques, thereby enhancing personal privacy protection.

Read more

6/6/2024

Phase-shifted remote photoplethysmography for estimating heart rate and blood pressure from facial video
Total Score

0

Phase-shifted remote photoplethysmography for estimating heart rate and blood pressure from facial video

Gyutae Hwang, Sang Jun Lee

Human health can be critically affected by cardiovascular diseases, such as hypertension, arrhythmias, and stroke. Heart rate and blood pressure are important biometric information for the monitoring of cardiovascular system and early diagnosis of cardiovascular diseases. Existing methods for estimating the heart rate are based on electrocardiography and photoplethyomography, which require contacting the sensor to the skin surface. Moreover, catheter and cuff-based methods for measuring blood pressure cause inconvenience and have limited applicability. Therefore, in this thesis, we propose a vision-based method for estimating the heart rate and blood pressure. This thesis proposes a 2-stage deep learning framework consisting of a dual remote photoplethysmography network (DRP-Net) and bounded blood pressure network (BBP-Net). In the first stage, DRP-Net infers remote photoplethysmography (rPPG) signals for the acral and facial regions, and these phase-shifted rPPG signals are utilized to estimate the heart rate. In the second stage, BBP-Net integrates temporal features and analyzes phase discrepancy between the acral and facial rPPG signals to estimate SBP and DBP values. To improve the accuracy of estimating the heart rate, we employed a data augmentation method based on a frame interpolation model. Moreover, we designed BBP-Net to infer blood pressure within a predefined range by incorporating a scaled sigmoid function. Our method resulted in estimating the heart rate with the mean absolute error (MAE) of 1.78 BPM, reducing the MAE by 34.31 % compared to the recent method, on the MMSE-HR dataset. The MAE for estimating the systolic blood pressure (SBP) and diastolic blood pressure (DBP) were 10.19 mmHg and 7.09 mmHg. On the V4V dataset, the MAE for the heart rate, SBP, and DBP were 3.83 BPM, 13.64 mmHg, and 9.4 mmHg, respectively.

Read more

8/27/2024

Chaos in Motion: Unveiling Robustness in Remote Heart Rate Measurement through Brain-Inspired Skin Tracking
Total Score

0

Chaos in Motion: Unveiling Robustness in Remote Heart Rate Measurement through Brain-Inspired Skin Tracking

Jie Wang, Jing Lian, Minjie Ma, Junqiang Lei, Chunbiao Li, Bin Li, Jizhao Liu

Heart rate is an important physiological indicator of human health status. Existing remote heart rate measurement methods typically involve facial detection followed by signal extraction from the region of interest (ROI). These SOTA methods have three serious problems: (a) inaccuracies even failures in detection caused by environmental influences or subject movement; (b) failures for special patients such as infants and burn victims; (c) privacy leakage issues resulting from collecting face video. To address these issues, we regard the remote heart rate measurement as the process of analyzing the spatiotemporal characteristics of the optical flow signal in the video. We apply chaos theory to computer vision tasks for the first time, thus designing a brain-inspired framework. Firstly, using an artificial primary visual cortex model to extract the skin in the videos, and then calculate heart rate by time-frequency analysis on all pixels. Our method achieves Robust Skin Tracking for Heart Rate measurement, called HR-RST. The experimental results show that HR-RST overcomes the difficulty of environmental influences and effectively tracks the subject movement. Moreover, the method could extend to other body parts. Consequently, the method can be applied to special patients and effectively protect individual privacy, offering an innovative solution.

Read more

4/12/2024

RhythmMamba: Fast Remote Physiological Measurement with Arbitrary Length Videos
Total Score

0

RhythmMamba: Fast Remote Physiological Measurement with Arbitrary Length Videos

Bochao Zou, Zizheng Guo, Xiaocheng Hu, Huimin Ma

Remote photoplethysmography (rPPG) is a non-contact method for detecting physiological signals from facial videos, holding great potential in various applications such as healthcare, affective computing, and anti-spoofing. Existing deep learning methods struggle to address two core issues of rPPG simultaneously: extracting weak rPPG signals from video segments with large spatiotemporal redundancy and understanding the periodic patterns of rPPG among long contexts. This represents a trade-off between computational complexity and the ability to capture long-range dependencies, posing a challenge for rPPG that is suitable for deployment on mobile devices. Based on the in-depth exploration of Mamba's comprehension of spatial and temporal information, this paper introduces RhythmMamba, an end-to-end Mamba-based method that employs multi-temporal Mamba to constrain both periodic patterns and short-term trends, coupled with frequency domain feed-forward to enable Mamba to robustly understand the quasi-periodic patterns of rPPG. Extensive experiments show that RhythmMamba achieves state-of-the-art performance with reduced parameters and lower computational complexity. The proposed RhythmMamba can be applied to video segments of any length without performance degradation. The codes are available at https://github.com/zizheng-guo/RhythmMamba.

Read more

4/10/2024