Phase-shifted remote photoplethysmography for estimating heart rate and blood pressure from facial video

Read original: arXiv:2401.04560 - Published 8/27/2024 by Gyutae Hwang, Sang Jun Lee
Total Score

0

Phase-shifted remote photoplethysmography for estimating heart rate and blood pressure from facial video

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • The paper presents a novel method called "phase-shifted remote photoplethysmography (PS-rPPG)" for estimating heart rate and blood pressure from facial video recordings.
  • This approach aims to improve upon existing remote photoplethysmography (rPPG) techniques by accounting for potential phase shifts in the signal.
  • The proposed method was evaluated through experiments on a dataset of facial videos and compared to traditional rPPG methods.

Plain English Explanation

The paper introduces a new way to measure a person's heart rate and blood pressure just by looking at a video of their face. This technique, called "phase-shifted remote photoplethysmography" (or PS-rPPG for short), builds on previous remote photoplethysmography (rPPG) methods.

Normally, rPPG measures small changes in the color of a person's skin that happen with each heartbeat. However, there can sometimes be a delay, or "phase shift," between the actual heart activity and the color changes seen in the video. The PS-rPPG approach accounts for this phase shift, which the researchers believe can lead to more accurate measurements of heart rate and blood pressure.

The researchers tested their PS-rPPG method by applying it to a dataset of facial video recordings and comparing the results to traditional rPPG techniques. This allowed them to evaluate the potential benefits of the new approach.

Technical Explanation

The paper presents a phase-shifted remote photoplethysmography (PS-rPPG) technique for estimating heart rate and blood pressure from facial video recordings. This builds upon previous remote photoplethysmography (rPPG) methods, which measure subtle changes in skin color caused by blood volume changes related to the cardiovascular cycle.

A key limitation of standard rPPG approaches is that they do not account for potential phase shifts between the actual heart activity and the observed color changes in the video. The PS-rPPG method introduced in this paper aims to address this by explicitly modeling the phase relationship between the rPPG signal and the underlying cardiovascular dynamics.

The researchers evaluated their PS-rPPG approach on a dataset of facial videos and compared the results to traditional rPPG techniques. This allowed them to assess the potential benefits of the phase-shifted modeling for improving the accuracy of heart rate and blood pressure estimation.

Critical Analysis

The paper presents a thoughtful approach to addressing a known limitation of standard rPPG methods - the potential for phase shifts between the observed color changes and the actual cardiovascular activity. By explicitly modeling this phase relationship, the PS-rPPG technique aims to provide more accurate heart rate and blood pressure estimates from facial video data.

However, the paper does acknowledge some caveats and limitations of the proposed method. For example, the experiments were conducted on a relatively small and potentially biased dataset, which could impact the generalizability of the findings. Additionally, the paper does not explore how the PS-rPPG method might perform under more challenging real-world conditions, such as varying lighting, head movements, or skin tones.

Further research would be needed to fully understand the strengths and weaknesses of the PS-rPPG approach compared to other rPPG techniques. It would be valuable to see evaluations on larger, more diverse datasets and comparisons to the latest advancements in remote cardiovascular monitoring from facial video.

Conclusion

This paper introduces a novel phase-shifted remote photoplethysmography (PS-rPPG) method that aims to improve the accuracy of heart rate and blood pressure estimation from facial video recordings. By accounting for potential phase shifts between the observed skin color changes and the underlying cardiovascular activity, the proposed technique represents an interesting advancement over standard rPPG approaches.

The experimental results suggest PS-rPPG may offer benefits in certain scenarios, though more research is needed to fully understand its strengths, limitations, and real-world applicability. Overall, this work contributes a valuable new perspective to the field of remote physiological monitoring using computer vision techniques.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Phase-shifted remote photoplethysmography for estimating heart rate and blood pressure from facial video
Total Score

0

Phase-shifted remote photoplethysmography for estimating heart rate and blood pressure from facial video

Gyutae Hwang, Sang Jun Lee

Human health can be critically affected by cardiovascular diseases, such as hypertension, arrhythmias, and stroke. Heart rate and blood pressure are important biometric information for the monitoring of cardiovascular system and early diagnosis of cardiovascular diseases. Existing methods for estimating the heart rate are based on electrocardiography and photoplethyomography, which require contacting the sensor to the skin surface. Moreover, catheter and cuff-based methods for measuring blood pressure cause inconvenience and have limited applicability. Therefore, in this thesis, we propose a vision-based method for estimating the heart rate and blood pressure. This thesis proposes a 2-stage deep learning framework consisting of a dual remote photoplethysmography network (DRP-Net) and bounded blood pressure network (BBP-Net). In the first stage, DRP-Net infers remote photoplethysmography (rPPG) signals for the acral and facial regions, and these phase-shifted rPPG signals are utilized to estimate the heart rate. In the second stage, BBP-Net integrates temporal features and analyzes phase discrepancy between the acral and facial rPPG signals to estimate SBP and DBP values. To improve the accuracy of estimating the heart rate, we employed a data augmentation method based on a frame interpolation model. Moreover, we designed BBP-Net to infer blood pressure within a predefined range by incorporating a scaled sigmoid function. Our method resulted in estimating the heart rate with the mean absolute error (MAE) of 1.78 BPM, reducing the MAE by 34.31 % compared to the recent method, on the MMSE-HR dataset. The MAE for estimating the systolic blood pressure (SBP) and diastolic blood pressure (DBP) were 10.19 mmHg and 7.09 mmHg. On the V4V dataset, the MAE for the heart rate, SBP, and DBP were 3.83 BPM, 13.64 mmHg, and 9.4 mmHg, respectively.

Read more

8/27/2024

🌐

Total Score

0

A Finger on the Pulse of Cardiovascular: Estimating Blood Pressure with Smartphone Photoplethysmography-Based Pulse Waveform Analysis

Ivan Liu, Fangyuan Liu, Qi Zhong, Shiguang Ni

Utilizing mobile phone cameras for continuous blood pressure (BP) monitoring presents a cost-effective and accessible approach, yet it is challenged by limitations in accuracy and interpretability. This study introduces four innovative strategies to enhance smartphone-based photoplethysmography for BP estimation (SPW-BP), addressing the interpretability-accuracy dilemma. First, we employ often-neglected data-quality improvement techniques, such as height normalization, corrupt data removal, and boundary signal reconstruction. Second, we conduct a comprehensive analysis of thirty waveform indicators across three categories to identify the most predictive features. Third, we use SHapley Additive exPlanations (SHAP) analysis to ensure the transparency and explainability of machine learning outcomes. Fourth, we utilize Bland-Altman analysis alongside AAMI and BHS standards for comparative evaluation. Data from 127 participants demonstrated a significant correlation between smartphone-captured waveform features and those from standard BP monitoring devices. Employing multiple linear regression within a cross-validation framework, waveform variables predicted systolic blood pressure (SBP) with a mean absolute error (MAE) of 3.08-16.64 mmHg and diastolic blood pressure (DBP) with an MAE of 2.86-13.16 mmHg. Further application of Random Forest models significantly improved the prediction MAE for SBP to 2.61-15.21 mmHg and for DBP to 2.14-11.22 mmHg, indicating enhanced predictive accuracy. Correlation and SHAP analysis identified key features for improving BP estimation. However, Bland-Altman analysis revealed systematic biases, and MAE analysis showed that the results did not meet AAMI and BHS accuracy standards. Our findings highlight the potential of SPW-BP, yet suggest that smartphone PPG technology is not yet a viable alternative to traditional medical devices for BP measurement.

Read more

7/25/2024

Total Score

0

Exploring the limitations of blood pressure estimation using the photoplethysmography signal

Felipe M. Dias, Diego A. C. Cardenas, Marcelo A. F. Toledo, Filipe A. C. Oliveira, Estela Ribeiro, Jose E. Krieger, Marco A. Gutierrez

Hypertension, a leading contributor to cardiovascular morbidity, underscores the need for accurate and continuous blood pressure (BP) monitoring. Photoplethysmography (PPG) presents a promising approach to this end. However, the precision of BP estimates derived from PPG signals has been the subject of ongoing debate, necessitating a comprehensive evaluation of their effectiveness and constraints. We developed a calibration-based Siamese ResNet model for BP estimation, using a signal input paired with a reference BP reading. We compared the use of normalized PPG (N-PPG) against the normalized Invasive Arterial Blood Pressure (N-IABP) signals as input. The N-IABP signals do not directly present systolic and diastolic values but theoretically provide a more accurate BP measure than PPG signals since it is a direct pressure sensor inside the body. Our strategy establishes a critical benchmark for PPG performance, realistically calibrating expectations for PPG's BP estimation capabilities. Nonetheless, we compared the performance of our models using different signal-filtering conditions to evaluate the impact of filtering on the results. We evaluated our method using the AAMI and the BHS standards employing the VitalDB dataset. The N-IABP signals meet with AAMI standards for both Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP), with errors of 1.29+-6.33mmHg for systolic pressure and 1.17+-5.78mmHg for systolic and diastolic pressure respectively for the raw N-IABP signal. In contrast, N-PPG signals, in their best setup, exhibited inferior performance than N-IABP, presenting 1.49+-11.82mmHg and 0.89+-7.27mmHg for systolic and diastolic pressure respectively. Our findings highlight the potential and limitations of employing PPG for BP estimation, showing that these signals contain information correlated to BP but may not be sufficient for predicting it accurately.

Read more

4/26/2024

Ghost imaging-based Non-contact Heart Rate Detection
Total Score

0

Ghost imaging-based Non-contact Heart Rate Detection

Jianming Yu, Yuchen He, Bin Li, Hui Chen, Huaibin Zheng, Jianbin Liu, Zhuo Xu

Remote heart rate measurement is an increasingly concerned research field, usually using remote photoplethysmography (rPPG) to collect heart rate information through video data collection. However, in certain specific scenarios (such as low light conditions, intense lighting, and non-line-of-sight situations), traditional imaging methods fail to capture image information effectively, that may lead to difficulty or inability in measuring heart rate. To address these limitations, this study proposes using ghost imaging as a substitute for traditional imaging in the aforementioned scenarios. The mean absolute error between experimental measurements and reference true values is 4.24 bpm.Additionally, the bucket signals obtained by the ghost imaging system can be directly processed using digital signal processing techniques, thereby enhancing personal privacy protection.

Read more

6/6/2024