Insights from the Design Space Exploration of Flow-Guided Nanoscale Localization

2305.18493

YC

0

Reddit

0

Published 5/30/2024 by Filip Lemic, Gerard Calvo Bartra, Arnau Brosa L'opez, Jorge Torres G'omez, Jakob Struye, Falko Dressler, Sergi Abadal, Xavier Costa Perez

🚀

Abstract

Nanodevices with Terahertz (THz)-based wireless communication capabilities are providing a primer for flow-guided localization within the human bloodstreams. Such localization is allowing for assigning the locations of sensed events with the events themselves, providing benefits in precision medicine along the lines of early and precise diagnostics, and reduced costs and invasiveness. Flow-guided localization is still in a rudimentary phase, with only a handful of works targeting the problem. Nonetheless, the performance assessments of the proposed solutions are already carried out in a non-standardized way, usually along a single performance metric, and ignoring various aspects that are relevant at such a scale (e.g., nanodevices' limited energy) and for such a challenging environment (e.g., extreme attenuation of in-body THz propagation). As such, these assessments feature low levels of realism and cannot be compared in an objective way. Toward addressing this issue, we account for the environmental and scale-related peculiarities of the scenario and assess the performance of two state-of-the-art flow-guided localization approaches along a set of heterogeneous performance metrics such as the accuracy and reliability of localization.

Create account to get full access

or

If you already have an account, we'll log you in

Overview

  • Nanodevices with terahertz (THz) wireless communication capabilities are enabling flow-guided localization within the human bloodstream
  • This localization allows for precise assignment of sensed events, which could benefit precision medicine through early and accurate diagnostics, and reduced costs and invasiveness
  • Current research on flow-guided localization has performance assessments that lack standardization, realism, and objective comparison across different approaches

Plain English Explanation

Tiny devices, called nanodevices, that can communicate using terahertz (THz) wireless signals are being developed to track their location within the human body, specifically in the bloodstream. This ability to pinpoint the location of these nanodevices as they move with the blood flow could lead to major advancements in precision medicine.

For example, being able to accurately locate where a nanodevice detects a health issue in the body could enable earlier and more targeted diagnostics. This could reduce the need for invasive procedures and lower medical costs. However, the current research on this flow-guided localization technology has some limitations.

The performance evaluations of different localization approaches are not standardized, so it is difficult to objectively compare them. Additionally, these assessments often do not fully account for the unique challenges of operating nanodevices in the human body, such as their limited energy supply and the extreme signal attenuation that can occur with THz communication inside the body.

As a result, the current performance claims may not reflect the true real-world capabilities of these localization systems. Addressing these shortcomings could lead to more reliable and impactful flow-guided localization technology for precision medicine applications.

Technical Explanation

The paper examines the state of research on flow-guided localization, where nanodevices with terahertz (THz)-based wireless communication capabilities are used to pinpoint their location within the human bloodstream. This localization approach has the potential to enable precise assignment of sensed events, leading to benefits in precision medicine, such as early and accurate diagnostics, and reduced costs and invasiveness.

However, the authors note that the performance assessments of the proposed flow-guided localization solutions are currently done in a non-standardized way, often focusing on a single metric and ignoring various relevant aspects at the nanodevice scale (e.g., limited energy) and the challenging in-body THz propagation environment. As a result, these assessments lack realism and cannot be objectively compared across different approaches.

To address this issue, the paper accounts for the environmental and scale-related peculiarities of the scenario and evaluates the performance of two state-of-the-art flow-guided localization approaches, G-Loc and XRLoc, along a set of heterogeneous performance metrics, such as the accuracy and reliability of localization.

Critical Analysis

The paper highlights a critical issue in the current research on flow-guided localization within the human bloodstream using nanodevices with THz wireless communication capabilities. The authors correctly point out that the performance assessments of the proposed solutions are often not standardized and do not adequately account for the unique challenges of this scenario, such as the limited energy of nanodevices and the extreme signal attenuation in the in-body THz propagation environment.

This lack of realism and objective comparison across different approaches limits the ability to accurately evaluate the true potential and limitations of flow-guided localization for precision medicine applications. The authors' proposal to assess the performance of two state-of-the-art approaches, G-Loc and XRLoc, along a set of heterogeneous metrics is a step in the right direction.

However, the paper does not address other potential challenges, such as the biocompatibility and long-term safety of the nanodevices, the potential for interference with normal bodily functions, and the scalability of the approach to larger numbers of nanodevices. Additionally, the paper does not provide a comprehensive survey of other localization techniques, such as those using Bluetooth or hybrid approaches combining multiple technologies, which could offer valuable insights.

Overall, the paper makes a compelling case for the need to address the shortcomings in the current research on flow-guided localization, and the authors' approach to evaluating the performance of existing solutions is a worthwhile contribution. However, a more holistic consideration of the challenges and a broader survey of alternative localization techniques could further strengthen the research.

Conclusion

This paper highlights the promising potential of nanodevices with terahertz (THz) wireless communication capabilities to enable flow-guided localization within the human bloodstream, which could benefit precision medicine through early and accurate diagnostics, and reduced costs and invasiveness.

However, the authors identify a critical issue in the current research on this topic - the performance assessments of the proposed solutions lack standardization, realism, and objective comparison. By accounting for the environmental and scale-related peculiarities of the scenario and evaluating the performance of two state-of-the-art approaches along a set of heterogeneous metrics, the paper takes a step towards addressing this problem.

Addressing these shortcomings in the current research could lead to more reliable and impactful flow-guided localization technology, ultimately contributing to the advancement of precision medicine and improved patient outcomes. Further research exploring the use of physics-guided neural networks for gas source localization may also offer valuable insights for improving the accuracy and robustness of in-body localization systems.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Related Papers

An Initial Study of Human-Scale Blockage in sub-THz Radio Propagation with Application to Indoor Passive Localization

An Initial Study of Human-Scale Blockage in sub-THz Radio Propagation with Application to Indoor Passive Localization

F. Paonessa, G. Virone, S. Kianoush, A. Nordio, S. Savazzi

YC

0

Reddit

0

This paper empirically investigates the body induced electromagnetic (EM) effects, namely the human body blockage, by conducting indoor measurement campaigns in the unexplored sub-THz W-band (75-110 GHz) and G-band (170-260 GHz). The proposed analysis focuses on both the alterations of channel frequency response induced by body presence, fully or partially obstructing the line-of-sight (LoS) between transmitter and recevier, as well as on the channel impulse response (CIR) for selected movements of the target, i.e. crossing the LoS of the radio link. Modelling of large scale parameters is also presented using a phantom body object. The proposed study has applications in device-free radio localization and radio frequency (RF) sensing scenarios where the EM radiation or environmental radio signals are collected and processed to detect and locate people without requiring them to wear any electronic devices. Although preliminary, the study reveals that discrimination of the blockage micro-movements is possible, achieving higher precision compared to classical RF sensing and localization using cm-scale wavelengths (2.4-6GHz bands).

Read more

6/26/2024

G-Loc: Tightly-coupled Graph Localization with Prior Topo-metric Information

G-Loc: Tightly-coupled Graph Localization with Prior Topo-metric Information

Lorenzo Montano-Oliv'an, Julio A. Placed, Luis Montano, Mar'ia T. L'azaro

YC

0

Reddit

0

Localization in already mapped environments is a critical component in many robotics and automotive applications, where previously acquired information can be exploited along with sensor fusion to provide robust and accurate localization estimates. In this work, we offer a new perspective on map-based localization by reusing prior topological and metric information. Thus, we reformulate this long-studied problem to go beyond the mere use of metric maps. Our framework seamlessly integrates LiDAR, iner-tial and GNSS measurements, and scan-to-map registrations in a sliding window graph fashion, which allows to accommodate the uncertainty of each observation. The modularity of our framework allows it to work with different sensor configurations (textit{e.g.,} LiDAR resolutions, GNSS denial) and environmental conditions (textit{e.g.,} map-less regions, large environments). We have conducted different validation experiments, including deployment in a real-world automotive application, demonstrating the accuracy, efficiency, and versatility of our system in online localization.

Read more

5/9/2024

🔄

XRLoc: Accurate UWB Localization to Realize XR Deployments

Aditya Arun, Shunsuke Saruwatari, Sureel Shah, Dinesh Bharadia

YC

0

Reddit

0

Understanding the location of ultra-wideband (UWB) tag-attached objects and people in the real world is vital to enabling a smooth cyber-physical transition. However, most UWB localization systems today require multiple anchors in the environment, which can be very cumbersome to set up. In this work, we develop XRLoc, providing an accuracy of a few centimeters in many real-world scenarios. This paper will delineate the key ideas which allow us to overcome the fundamental restrictions that plague a single anchor point from localization of a device to within an error of a few centimeters. We deploy a VR chess game using everyday objects as a demo and find that our system achieves $2.4$ cm median accuracy and $5.3$ cm $90^mathrm{th}$ percentile accuracy in dynamic scenarios, performing at least $8times$ better than state-of-art localization systems. Additionally, we implement a MAC protocol to furnish these locations for over $10$ tags at update rates of $100$ Hz, with a localization latency of $sim 1$ ms.

Read more

5/6/2024

Kalman filter based localization in hybrid BLE-UWB positioning system

Kalman filter based localization in hybrid BLE-UWB positioning system

Marcin Kolakowski

YC

0

Reddit

0

In this paper a concept of hybrid Bluetooth Low Energy (BLE) Ultra-wideband (UWB) positioning system is presented. The system is intended to be energy efficient. Low energy BLE unit is used as a primary source of measurement data and for most of the time localization is calculated based on received signal strength (RSS). UWB technology is used less often. Time difference of arrival (TDOA) values measured with UWB radios are periodically used to improve RSS based localization. The paper contains a description of proposed hybrid positioning algorithm. Results of simulations and experiments confirming algorithm's efficiency are also included.

Read more

4/4/2024