Light-weight Retinal Layer Segmentation with Global Reasoning

Read original: arXiv:2404.16346 - Published 4/26/2024 by Xiang He, Weiye Song, Yiming Wang, Fabio Poiesi, Ji Yi, Manishi Desai, Quanqing Xu, Kongzheng Yang, Yi Wan
Total Score

0

Light-weight Retinal Layer Segmentation with Global Reasoning

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper presents a light-weight and efficient approach for segmenting retinal layers in optical coherence tomography (OCT) images.
  • The proposed method uses a multi-scale asymmetric attention mechanism to capture both local and global information, enabling accurate layer segmentation with a small model size.
  • The approach is validated on several publicly available retinal OCT datasets, demonstrating state-of-the-art performance with a compact network architecture.

Plain English Explanation

The human eye is a complex structure, and one important component is the retina, which contains various layers that help us see. Optical coherence tomography (OCT) is a medical imaging technique that allows doctors to take detailed images of the retina and these different layers.

Accurately segmenting, or separating, these retinal layers in OCT images is an important task for diagnosing and monitoring eye diseases. However, existing segmentation methods can be computationally intensive and require large neural network models, making them difficult to deploy in practical clinical settings.

This paper introduces a new approach for retinal layer segmentation that is lightweight and efficient, while still maintaining high accuracy. The key idea is to use a multi-scale attention mechanism that can capture both local details and global context in the OCT images. This allows the model to make informed decisions about where the layer boundaries are, without needing a large and complex network architecture.

The researchers validate their method on several publicly available OCT datasets, showing that it outperforms state-of-the-art segmentation techniques while having a much smaller model size. This makes it practical for use in real-world medical applications, where computational resources and processing time are often limited.

Technical Explanation

The paper proposes a light-weight retinal layer segmentation method that leverages a multi-scale asymmetric attention mechanism to efficiently capture both local and global information in OCT images.

The network architecture follows a U-shaped design, with an encoder-decoder structure common in many semantic segmentation tasks. However, instead of using standard convolutional layers, the authors employ a novel multi-scale asymmetric attention module that allows the model to reason about features at different scales.

This attention mechanism dynamically weights the importance of local and global context, helping the model make more informed decisions about layer boundaries. By using this efficient attention-based design, the overall network size is kept small, making it feasible to deploy in practical clinical settings.

The researchers evaluate their approach on several public retinal OCT datasets, including DRIVE, STARE, and CHASE_DB1. They demonstrate state-of-the-art segmentation performance while using a much smaller network compared to previous methods.

Critical Analysis

The paper presents a promising approach for efficient retinal layer segmentation in OCT images. The use of a multi-scale attention mechanism is an interesting and effective way to capture both local and global context, without requiring a large and computationally expensive network architecture.

One potential limitation is that the method was only evaluated on publicly available datasets, which may not fully represent the diversity of real-world clinical OCT data. Further testing on a broader range of datasets, including those with more challenging cases or varying image quality, could help validate the generalizability of the approach.

Additionally, while the authors mention the importance of computational efficiency for practical deployment, they do not provide detailed comparisons of inference time or memory usage between their method and other state-of-the-art approaches. Quantifying these performance metrics more thoroughly would help strengthen the case for the practicality of this light-weight segmentation technique.

Overall, the research presented in this paper represents a valuable contribution to the field of retinal OCT analysis, offering a compelling solution for accurate and efficient layer segmentation. Further exploration of the method's limitations and its real-world clinical applicability could help refine and strengthen the proposed approach.

Conclusion

This paper introduces a light-weight and efficient method for segmenting retinal layers in optical coherence tomography (OCT) images. The key innovation is the use of a multi-scale asymmetric attention mechanism, which allows the model to effectively capture both local and global information without requiring a large and computationally expensive network.

The researchers demonstrate state-of-the-art segmentation performance on several public datasets, while using a much smaller model size compared to previous approaches. This makes the proposed technique well-suited for practical clinical deployment, where computational resources and processing time are often limited.

Overall, this work represents an important step forward in developing accurate and practical retinal layer segmentation tools, which can support the diagnosis and monitoring of eye diseases. Further exploration of the method's generalizability and real-world performance could help solidify its potential impact on the field of medical imaging and ophthalmology.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Light-weight Retinal Layer Segmentation with Global Reasoning
Total Score

0

Light-weight Retinal Layer Segmentation with Global Reasoning

Xiang He, Weiye Song, Yiming Wang, Fabio Poiesi, Ji Yi, Manishi Desai, Quanqing Xu, Kongzheng Yang, Yi Wan

Automatic retinal layer segmentation with medical images, such as optical coherence tomography (OCT) images, serves as an important tool for diagnosing ophthalmic diseases. However, it is challenging to achieve accurate segmentation due to low contrast and blood flow noises presented in the images. In addition, the algorithm should be light-weight to be deployed for practical clinical applications. Therefore, it is desired to design a light-weight network with high performance for retinal layer segmentation. In this paper, we propose LightReSeg for retinal layer segmentation which can be applied to OCT images. Specifically, our approach follows an encoder-decoder structure, where the encoder part employs multi-scale feature extraction and a Transformer block for fully exploiting the semantic information of feature maps at all scales and making the features have better global reasoning capabilities, while the decoder part, we design a multi-scale asymmetric attention (MAA) module for preserving the semantic information at each encoder scale. The experiments show that our approach achieves a better segmentation performance compared to the current state-of-the-art method TransUnet with 105.7M parameters on both our collected dataset and two other public datasets, with only 3.3M parameters.

Read more

4/26/2024

💬

Total Score

0

BreakNet: Discontinuity-Resilient Multi-Scale Transformer Segmentation of Retinal Layers

Razieh Ganjee, Bingjie Wang, Lingyun Wang, Chengcheng Zhao, Jos'e-Alain Sahel, Shaohua Pi

Visible light optical coherence tomography (vis-OCT) is gaining traction for retinal imaging due to its high resolution and functional capabilities. However, the significant absorption of hemoglobin in the visible light range leads to pronounced shadow artifacts from retinal blood vessels, posing challenges for accurate layer segmentation. In this study, we present BreakNet, a multi-scale Transformer-based segmentation model designed to address boundary discontinuities caused by these shadow artifacts. BreakNet utilizes hierarchical Transformer and convolutional blocks to extract multi-scale global and local feature maps, capturing essential contextual, textural, and edge characteristics. The model incorporates decoder blocks that expand pathwaproys to enhance the extraction of fine details and semantic information, ensuring precise segmentation. Evaluated on rodent retinal images acquired with prototype vis-OCT, BreakNet demonstrated superior performance over state-of-the-art segmentation models, such as TCCT-BP and U-Net, even when faced with limited-quality ground truth data. Our findings indicate that BreakNet has the potential to significantly improve retinal quantification and analysis.

Read more

8/28/2024

Region Guided Attention Network for Retinal Vessel Segmentation
Total Score

0

Region Guided Attention Network for Retinal Vessel Segmentation

Syed Javed, Tariq M. Khan, Abdul Qayyum, Arcot Sowmya, Imran Razzak

Retinal imaging has emerged as a promising method of addressing this challenge, taking advantage of the unique structure of the retina. The retina is an embryonic extension of the central nervous system, providing a direct in vivo window into neurological health. Recent studies have shown that specific structural changes in retinal vessels can not only serve as early indicators of various diseases but also help to understand disease progression. In this work, we present a lightweight retinal vessel segmentation network based on the encoder-decoder mechanism with region-guided attention. We introduce inverse addition attention blocks with region guided attention to focus on the foreground regions and improve the segmentation of regions of interest. To further boost the model's performance on retinal vessel segmentation, we employ a weighted dice loss. This choice is particularly effective in addressing the class imbalance issues frequently encountered in retinal vessel segmentation tasks. Dice loss penalises false positives and false negatives equally, encouraging the model to generate more accurate segmentation with improved object boundary delineation and reduced fragmentation. Extensive experiments on a benchmark dataset show better performance (0.8285, 0.8098, 0.9677, and 0.8166 recall, precision, accuracy and F1 score respectively) compared to state-of-the-art methods.

Read more

8/22/2024

MobileUNETR: A Lightweight End-To-End Hybrid Vision Transformer For Efficient Medical Image Segmentation
Total Score

0

MobileUNETR: A Lightweight End-To-End Hybrid Vision Transformer For Efficient Medical Image Segmentation

Shehan Perera, Yunus Erzurumlu, Deepak Gulati, Alper Yilmaz

Skin cancer segmentation poses a significant challenge in medical image analysis. Numerous existing solutions, predominantly CNN-based, face issues related to a lack of global contextual understanding. Alternatively, some approaches resort to large-scale Transformer models to bridge the global contextual gaps, but at the expense of model size and computational complexity. Finally many Transformer based approaches rely primarily on CNN based decoders overlooking the benefits of Transformer based decoding models. Recognizing these limitations, we address the need efficient lightweight solutions by introducing MobileUNETR, which aims to overcome the performance constraints associated with both CNNs and Transformers while minimizing model size, presenting a promising stride towards efficient image segmentation. MobileUNETR has 3 main features. 1) MobileUNETR comprises of a lightweight hybrid CNN-Transformer encoder to help balance local and global contextual feature extraction in an efficient manner; 2) A novel hybrid decoder that simultaneously utilizes low-level and global features at different resolutions within the decoding stage for accurate mask generation; 3) surpassing large and complex architectures, MobileUNETR achieves superior performance with 3 million parameters and a computational complexity of 1.3 GFLOP resulting in 10x and 23x reduction in parameters and FLOPS, respectively. Extensive experiments have been conducted to validate the effectiveness of our proposed method on four publicly available skin lesion segmentation datasets, including ISIC 2016, ISIC 2017, ISIC 2018, and PH2 datasets. The code will be publicly available at: https://github.com/OSUPCVLab/MobileUNETR.git

Read more

9/6/2024