  • This paper presents a model-driven approach to heart rate estimation and heart murmur detection using phonocardiogram (PCG) signals.
  • The authors develop a novel signal processing pipeline that combines mathematical models of the cardiac cycle with deep learning techniques.
  • The proposed system aims to provide accurate and reliable cardiac monitoring for healthcare applications.

Plain English Explanation

The research paper describes a new method for analyzing heart sounds using a device called a phonocardiogram (PCG). A PCG records the sounds made by the heart as it beats. The researchers developed a computer system that can automatically detect and measure important characteristics of these heart sounds, like the heart rate and whether there are any abnormal "murmurs."

The key idea is to combine mathematical models of how the heart works with deep learning algorithms. The mathematical models help the system understand the normal patterns in healthy heart sounds. The deep learning components then use this knowledge to identify abnormalities, like murmurs, that could indicate a heart problem.

This approach allows the system to provide accurate heart monitoring without requiring extensive manual analysis by a doctor. The researchers tested their method on real PCG recordings and showed that it could reliably estimate the heart rate and detect the presence of murmurs. This could be useful for screening patients or continuously tracking their heart health in a medical setting.

Technical Explanation

The paper introduces a model-driven approach to heart rate estimation and heart murmur detection using PCG signals. The key components include:

The authors evaluate their approach on a dataset of real PCG recordings and demonstrate its effectiveness at estimating heart rate and detecting heart murmurs compared to baseline methods.

Critical Analysis

The paper presents a novel and technically sophisticated approach to cardiac signal analysis. Some potential limitations and areas for further research include:

Further research could explore ways to make the system more robust and adaptable to real-world conditions, as well as investigate its performance on larger and more diverse datasets.

Conclusion

This paper presents a innovative approach to heart rate estimation and heart murmur detection using PCG signals. By combining mathematical models of cardiac physiology with deep learning techniques, the researchers have developed a system that can provide accurate and reliable cardiac monitoring. While the method has some potential limitations, it represents an important step forward in the field of intelligent cardiac auscultation and could have significant implications for healthcare applications.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Model-driven Heart Rate Estimation and Heart Murmur Detection based on Phonocardiogram
Total Score

0

Model-driven Heart Rate Estimation and Heart Murmur Detection based on Phonocardiogram

Jingping Nie, Ran Liu, Behrooz Mahasseni, Erdrin Azemi, Vikramjit Mitra

Acoustic signals are crucial for health monitoring, particularly heart sounds which provide essential data like heart rate and detect cardiac anomalies such as murmurs. This study utilizes a publicly available phonocardiogram (PCG) dataset to estimate heart rate using model-driven methods and extends the best-performing model to a multi-task learning (MTL) framework for simultaneous heart rate estimation and murmur detection. Heart rate estimates are derived using a sliding window technique on heart sound snippets, analyzed with a combination of acoustic features (Mel spectrogram, cepstral coefficients, power spectral density, root mean square energy). Our findings indicate that a 2D convolutional neural network (textbf{texttt{2dCNN}}) is most effective for heart rate estimation, achieving a mean absolute error (MAE) of 1.312 bpm. We systematically investigate the impact of different feature combinations and find that utilizing all four features yields the best results. The MTL model (textbf{texttt{2dCNN-MTL}}) achieves accuracy over 95% in murmur detection, surpassing existing models, while maintaining an MAE of 1.636 bpm in heart rate estimation, satisfying the requirements stated by Association for the Advancement of Medical Instrumentation (AAMI).

Read more

7/29/2024

🔎

Total Score

0

Intelligent Cardiac Auscultation for Murmur Detection via Parallel-Attentive Models with Uncertainty Estimation

Zixing Zhang, Tao Pang, Jing Han, Bjorn W. Schuller

Heart murmurs are a common manifestation of cardiovascular diseases and can provide crucial clues to early cardiac abnormalities. While most current research methods primarily focus on the accuracy of models, they often overlook other important aspects such as the interpretability of machine learning algorithms and the uncertainty of predictions. This paper introduces a heart murmur detection method based on a parallel-attentive model, which consists of two branches: One is based on a self-attention module and the other one is based on a convolutional network. Unlike traditional approaches, this structure is better equipped to handle long-term dependencies in sequential data, and thus effectively captures the local and global features of heart murmurs. Additionally, we acknowledge the significance of understanding the uncertainty of model predictions in the medical field for clinical decision-making. Therefore, we have incorporated an effective uncertainty estimation method based on Monte Carlo Dropout into our model. Furthermore, we have employed temperature scaling to calibrate the predictions of our probabilistic model, enhancing its reliability. In experiments conducted on the CirCor Digiscope dataset for heart murmur detection, our proposed method achieves a weighted accuracy of 79.8% and an F1 of 65.1%, representing state-of-the-art results.

Read more

5/8/2024

🤿

Total Score

0

FunnelNet: An End-to-End Deep Learning Framework to Monitor Digital Heart Murmur in Real-Time

Md Jobayer, Md. Mehedi Hasan Shawon, Md Rakibul Hasan, Shreya Ghosh, Tom Gedeon, Md Zakir Hossain

Objective: Heart murmurs are abnormal sounds caused by turbulent blood flow within the heart. Several diagnostic methods are available to detect heart murmurs and their severity, such as cardiac auscultation, echocardiography, phonocardiogram (PCG), etc. However, these methods have limitations, including extensive training and experience among healthcare providers, cost and accessibility of echocardiography, as well as noise interference and PCG data processing. This study aims to develop a novel end-to-end real-time heart murmur detection approach using traditional and depthwise separable convolutional networks. Methods: Continuous wavelet transform (CWT) was applied to extract meaningful features from the PCG data. The proposed network has three parts: the Squeeze net, the Bottleneck, and the Expansion net. The Squeeze net generates a compressed data representation, whereas the Bottleneck layer reduces computational complexity using a depthwise-separable convolutional network. The Expansion net is responsible for up-sampling the compressed data to a higher dimension, capturing tiny details of the representative data. Results: For evaluation, we used four publicly available datasets and achieved state-of-the-art performance in all datasets. Furthermore, we tested our proposed network on two resource-constrained devices: a Raspberry PI and an Android device, stripping it down into a tiny machine learning model (TinyML), achieving a maximum of 99.70%. Conclusion: The proposed model offers a deep learning framework for real-time accurate heart murmur detection within limited resources. Significance: It will significantly result in more accessible and practical medical services and reduced diagnosis time to assist medical professionals. The code is publicly available at TBA.

Read more

5/17/2024

🔎

Total Score

0

Heart Murmur and Abnormal PCG Detection via Wavelet Scattering Transform & a 1D-CNN

Ahmed Patwa, Muhammad Mahboob Ur Rahman, Tareq Y. Al-Naffouri

Heart murmurs provide valuable information about mechanical activity of the heart, which aids in diagnosis of various heart valve diseases. This work does automatic and accurate heart murmur detection from phonocardiogram (PCG) recordings. Two public PCG datasets (CirCor Digiscope 2022 dataset and PCG 2016 dataset) from Physionet online database are utilized to train and test three custom neural networks (NN): a 1D convolutional neural network (CNN), a long short-term memory (LSTM) recurrent neural network (RNN), and a convolutional RNN (C-RNN). We first do pre-processing which includes the following key steps: denoising, segmentation, re-labeling of noise-only segments, data normalization, and time-frequency analysis of the PCG segments using wavelet scattering transform. We then conduct four experiments, first three (E1-E3) using PCG 2022 dataset, and fourth (E4) using PCG 2016 dataset. It turns out that our custom 1D-CNN outperforms other two NNs (LSTM-RNN and C-RNN). Further, our 1D-CNN model outperforms the related work in terms of accuracy, weighted accuracy, F1-score and AUROC, for experiment E3 (that utilizes the cleaned and re-labeled PCG 2022 dataset). As for experiment E1 (that utilizes the original PCG 2022 dataset), our model performs quite close to the related work in terms of weighted accuracy and F1-score.