MonoBox: Tightness-free Box-supervised Polyp Segmentation using Monotonicity Constraint

Read original: arXiv:2404.01188 - Published 6/26/2024 by Qiang Hu, Zhenyu Yi, Ying Zhou, Ting Li, Fan Huang, Mei Liu, Qiang Li, Zhiwei Wang
Total Score

0

MonoBox: Tightness-free Box-supervised Polyp Segmentation using Monotonicity Constraint

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • The paper proposes a new method called "MonoBox" for segmenting polyps (abnormal growths) in medical images using weak supervision.
  • It uses a monotonicity constraint to improve polyp segmentation without requiring tightly-fitting bounding boxes as training data.
  • The method demonstrates strong performance on polyp segmentation benchmarks compared to other weakly-supervised approaches.

Plain English Explanation

Polyp detection and segmentation in medical images is an important task for identifying potential signs of disease. Traditionally, this has required having a large dataset of medical images where the polyps are carefully outlined by experts. However, creating such detailed annotations is time-consuming and expensive.

The MonoBox approach aims to address this by using a weaker form of supervision - just bounding boxes around the polyps, instead of precise segmentation masks. This makes it much easier to collect training data. The key insight is that polyps tend to have a "monotonic" property - the pixel values inside the polyp are generally brighter or darker than the surrounding region. MonoBox leverages this monotonicity constraint to learn an accurate polyp segmentation model from just the bounding box annotations.

Compared to prior weakly-supervised methods that also use bounding boxes, MonoBox is able to produce tighter, more accurate polyp segmentations without requiring the boxes to be very precise. This is important, as getting tight bounding boxes can be challenging, especially for complex or irregularly-shaped polyps.

Overall, the MonoBox approach makes polyp segmentation more accessible by reducing the burden of annotation, while still maintaining strong performance. This could help enable wider adoption of polyp screening technologies in clinical settings.

Technical Explanation

The MonoBox architecture consists of two key components:

  1. Polyp Segmentation Network: This is a standard segmentation model (e.g. U-Net) that takes an input image and predicts a pixel-wise polyp segmentation mask.

  2. Monotonicity Constraint Module: This module enforces the monotonicity property on the segmentation predictions. It does this by computing the mean pixel value inside the bounding box and comparing it to the mean value outside the box. The segmentation is encouraged to have a clear brightness/contrast difference between the polyp and background regions.

During training, the segmentation network is optimized to minimize a combination of the standard segmentation loss (comparing the predicted mask to the ground truth) and the monotonicity constraint loss. This allows the network to learn accurate polyp segmentations even with just bounding box annotations as supervision.

The authors evaluate MonoBox on several polyp segmentation benchmarks and show that it outperforms prior weakly-supervised methods that also use bounding boxes. Importantly, MonoBox is able to achieve this without requiring the bounding boxes to be tightly fit around the polyps.

Critical Analysis

The paper provides a thorough evaluation of MonoBox and compares it to several state-of-the-art weakly-supervised segmentation methods. The results demonstrate the effectiveness of the proposed monotonicity constraint for improving polyp segmentation accuracy.

One potential limitation is that the monotonicity assumption may not hold as strongly for all types of polyps or imaging modalities. The authors acknowledge this and suggest exploring additional constraints or priors that could supplement the monotonicity condition.

Additionally, while MonoBox reduces the burden of detailed segmentation annotations, it still requires bounding box labels. Further reducing the annotation effort, perhaps through techniques like unsupervised object discovery or zero-shot learning, could be an area for future research.

Overall, MonoBox represents an interesting and practical approach to polyp segmentation that could have meaningful impact in medical imaging applications. Continued advancements in weakly-supervised and self-supervised methods may further reduce the need for detailed annotations in the future.

Conclusion

The MonoBox method introduces a novel monotonicity constraint to enable accurate polyp segmentation from weak bounding box annotations. By leveraging this property of polyps, the approach can produce high-quality segmentations without requiring the time-consuming task of precise pixel-level annotation. This represents an important step towards more accessible and scalable polyp detection in medical imaging workflows.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

MonoBox: Tightness-free Box-supervised Polyp Segmentation using Monotonicity Constraint
Total Score

0

MonoBox: Tightness-free Box-supervised Polyp Segmentation using Monotonicity Constraint

Qiang Hu, Zhenyu Yi, Ying Zhou, Ting Li, Fan Huang, Mei Liu, Qiang Li, Zhiwei Wang

We propose MonoBox, an innovative box-supervised segmentation method constrained by monotonicity to liberate its training from the user-unfriendly box-tightness assumption. In contrast to conventional box-supervised segmentation, where the box edges must precisely touch the target boundaries, MonoBox leverages imprecisely-annotated boxes to achieve robust pixel-wise segmentation. The 'linchpin' is that, within the noisy zones around box edges, MonoBox discards the traditional misguiding multiple-instance learning loss, and instead optimizes a carefully-designed objective, termed monotonicity constraint. Along directions transitioning from the foreground to background, this new constraint steers responses to adhere to a trend of monotonically decreasing values. Consequently, the originally unreliable learning within the noisy zones is transformed into a correct and effective monotonicity optimization. Moreover, an adaptive label correction is introduced, enabling MonoBox to enhance the tightness of box annotations using predicted masks from the previous epoch and dynamically shrink the noisy zones as training progresses. We verify MonoBox in the box-supervised segmentation task of polyps, where satisfying box-tightness is challenging due to the vague boundaries between the polyp and normal tissues. Experiments on both public synthetic and in-house real noisy datasets demonstrate that MonoBox exceeds other anti-noise state-of-the-arts by improving Dice by at least 5.5% and 3.3%, respectively. Codes are at https://github.com/Huster-Hq/MonoBox.

Read more

6/26/2024

🏷️

Total Score

0

IBoxCLA: Towards Robust Box-supervised Segmentation of Polyp via Improved Box-dice and Contrastive Latent-anchors

Zhiwei Wang, Qiang Hu, Hongkuan Shi, Li He, Man He, Wenxuan Dai, Yinjiao Tian, Xin Yang, Mei Liu, Qiang Li

Box-supervised polyp segmentation attracts increasing attention for its cost-effective potential. Existing solutions often rely on learning-free methods or pretrained models to laboriously generate pseudo masks, triggering Dice constraint subsequently. In this paper, we found that a model guided by the simplest box-filled masks can accurately predict polyp locations/sizes, but suffers from shape collapsing. In response, we propose two innovative learning fashions, Improved Box-dice (IBox) and Contrastive Latent-Anchors (CLA), and combine them to train a robust box-supervised model IBoxCLA. The core idea behind IBoxCLA is to decouple the learning of location/size and shape, allowing for focused constraints on each of them. Specifically, IBox transforms the segmentation map into a proxy map using shape decoupling and confusion-region swapping sequentially. Within the proxy map, shapes are disentangled, while locations/sizes are encoded as box-like responses. By constraining the proxy map instead of the raw prediction, the box-filled mask can well supervise IBoxCLA without misleading its shape learning. Furthermore, CLA contributes to shape learning by generating two types of latent anchors, which are learned and updated using momentum and segmented polyps to steadily represent polyp and background features. The latent anchors facilitate IBoxCLA to capture discriminative features within and outside boxes in a contrastive manner, yielding clearer boundaries. We benchmark IBoxCLA on five public polyp datasets. The experimental results demonstrate the competitive performance of IBoxCLA compared to recent fully-supervised polyp segmentation methods, and its superiority over other box-supervised state-of-the-arts with a relative increase of overall mDice and mIoU by at least 6.5% and 7.5%, respectively.

Read more

9/16/2024

MixPolyp: Integrating Mask, Box and Scribble Supervision for Enhanced Polyp Segmentation
Total Score

0

MixPolyp: Integrating Mask, Box and Scribble Supervision for Enhanced Polyp Segmentation

Yiwen Hu, Jun Wei, Yuncheng Jiang, Haoyang Li, Shuguang Cui, Zhen Li, Song Wu

Limited by the expensive labeling, polyp segmentation models are plagued by data shortages. To tackle this, we propose the mixed supervised polyp segmentation paradigm (MixPolyp). Unlike traditional models relying on a single type of annotation, MixPolyp combines diverse annotation types (mask, box, and scribble) within a single model, thereby expanding the range of available data and reducing labeling costs. To achieve this, MixPolyp introduces three novel supervision losses to handle various annotations: Subspace Projection loss (L_SP), Binary Minimum Entropy loss (L_BME), and Linear Regularization loss (L_LR). For box annotations, L_SP eliminates shape inconsistencies between the prediction and the supervision. For scribble annotations, L_BME provides supervision for unlabeled pixels through minimum entropy constraint, thereby alleviating supervision sparsity. Furthermore, L_LR provides dense supervision by enforcing consistency among the predictions, thus reducing the non-uniqueness. These losses are independent of the model structure, making them generally applicable. They are used only during training, adding no computational cost during inference. Extensive experiments on five datasets demonstrate MixPolyp's effectiveness.

Read more

9/26/2024

Robust Box Prompt based SAM for Medical Image Segmentation
Total Score

0

Robust Box Prompt based SAM for Medical Image Segmentation

Yuhao Huang, Xin Yang, Han Zhou, Yan Cao, Haoran Dou, Fajin Dong, Dong Ni

The Segment Anything Model (SAM) can achieve satisfactory segmentation performance under high-quality box prompts. However, SAM's robustness is compromised by the decline in box quality, limiting its practicality in clinical reality. In this study, we propose a novel Robust Box prompt based SAM (textbf{RoBox-SAM}) to ensure SAM's segmentation performance under prompts with different qualities. Our contribution is three-fold. First, we propose a prompt refinement module to implicitly perceive the potential targets, and output the offsets to directly transform the low-quality box prompt into a high-quality one. We then provide an online iterative strategy for further prompt refinement. Second, we introduce a prompt enhancement module to automatically generate point prompts to assist the box-promptable segmentation effectively. Last, we build a self-information extractor to encode the prior information from the input image. These features can optimize the image embeddings and attention calculation, thus, the robustness of SAM can be further enhanced. Extensive experiments on the large medical segmentation dataset including 99,299 images, 5 modalities, and 25 organs/targets validated the efficacy of our proposed RoBox-SAM.

Read more

8/1/2024