IBoxCLA: Towards Robust Box-supervised Segmentation of Polyp via Improved Box-dice and Contrastive Latent-anchors

Read original: arXiv:2310.07248 - Published 9/16/2024 by Zhiwei Wang, Qiang Hu, Hongkuan Shi, Li He, Man He, Wenxuan Dai, Yinjiao Tian, Xin Yang, Mei Liu, Qiang Li
Total Score

0

🏷️

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Box-supervised polyp segmentation is a cost-effective approach that has gained increasing attention.
  • Existing solutions often rely on learning-free methods or pretrained models to generate pseudo masks, which can be labor-intensive.
  • The paper proposes two innovative learning techniques, Improved Box-dice (IBox) and Contrastive Latent-Anchors (CLA), and combines them to train a robust box-supervised model called IBoxCLA.

Plain English Explanation

Box-supervised polyp segmentation is a way to identify and outline the location of polyps in medical images without the need for detailed, pixel-level labeling. This is an attractive approach because it is more cost-effective than traditional, fully-supervised methods that require a lot of manual effort to create precise segmentation masks.

However, existing box-supervised solutions often rely on complex, time-consuming steps to generate pseudo masks that approximate the true polyp shapes. The paper's authors found that a simpler model guided by just box-filled masks could accurately predict the location and size of polyps, but struggled to capture the proper shape.

To address this, the researchers developed two new techniques called IBox and CLA. IBox transforms the segmentation map into a "proxy map" that disentangles the shape information while still encoding the location and size as box-like responses. This allows the box-filled masks to effectively supervise the model's learning without misleading its shape prediction.

Additionally, CLA generates two types of latent anchors that represent polyp and background features. These anchors help the model learn more discriminative features, leading to clearer polyp boundaries.

By combining IBox and CLA, the researchers created the IBoxCLA model, which demonstrated competitive performance compared to fully-supervised polyp segmentation methods, and outperformed other box-supervised approaches by a significant margin.

Technical Explanation

The IBoxCLA model is designed to address the limitations of existing box-supervised polyp segmentation solutions. It consists of two key components:

  1. Improved Box-dice (IBox): IBox transforms the segmentation map into a "proxy map" through two steps: shape decoupling and confusion-region swapping. This allows the box-filled masks to effectively supervise the model's learning of polyp locations and sizes, without misleading its shape prediction.

  2. Contrastive Latent-Anchors (CLA): CLA generates two types of latent anchors that represent polyp and background features. These anchors are learned and updated using momentum and segmented polyps, helping the model capture more discriminative features within and outside the box annotations.

By combining IBox and CLA, the IBoxCLA model is able to decouple the learning of location/size and shape, allowing for focused constraints on each aspect. This results in a more robust box-supervised polyp segmentation system.

The researchers benchmarked IBoxCLA on five public polyp datasets and found that it outperformed other box-supervised state-of-the-art methods, with a relative increase of overall mDice and mIoU by at least 6.5% and 7.5%, respectively. The model also demonstrated competitive performance compared to recent fully-supervised polyp segmentation techniques, such as PCLMix and Bayesian Uncertainty Weighted Loss.

Critical Analysis

The paper presents a compelling approach to box-supervised polyp segmentation, but there are a few potential areas for further research and consideration:

  1. Generalization Across Datasets: While the IBoxCLA model performed well on the tested datasets, it would be valuable to evaluate its performance on a wider range of polyp datasets, especially those with more diverse characteristics or from different healthcare systems.

  2. Robustness to Annotation Quality: The paper assumes that the box annotations provided are accurate and representative of the true polyp shapes. It would be interesting to explore the model's sensitivity to variations or imprecisions in the box annotations, which may be common in real-world scenarios.

  3. Computational Efficiency: The authors do not provide detailed information about the computational requirements or inference time of the IBoxCLA model. As real-time performance is often crucial in medical applications, this aspect could be an important consideration for practical deployment.

  4. Interpretability and Explainability: While the model's performance is promising, it would be valuable to better understand the internal workings and decision-making processes of the IBoxCLA model. Increased interpretability could lead to better trust and acceptance in the medical community.

Overall, the IBoxCLA approach represents a significant advancement in box-supervised polyp segmentation, with the potential to reduce the burden of manual annotation while maintaining high accuracy. Further research exploring the model's generalization, robustness, and interpretability could help solidify its practical applicability in real-world clinical settings.

Conclusion

The paper introduces the IBoxCLA model, a novel box-supervised polyp segmentation technique that combines two innovative learning components, IBox and CLA. By decoupling the learning of location/size and shape, and leveraging contrastive latent anchors, IBoxCLA is able to outperform other box-supervised methods and achieve competitive results compared to fully-supervised approaches.

This research represents a significant advancement in cost-effective polyp segmentation, with the potential to reduce the burden of manual annotation while maintaining high accuracy. The techniques developed in this paper could also have broader applications in other medical image segmentation tasks that rely on box-level supervision.

As the field of box-supervised medical image analysis continues to evolve, the IBoxCLA model and the insights presented in this paper provide a valuable contribution to the ongoing efforts to improve the efficiency and effectiveness of computer-assisted diagnosis and treatment.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🏷️

Total Score

0

IBoxCLA: Towards Robust Box-supervised Segmentation of Polyp via Improved Box-dice and Contrastive Latent-anchors

Zhiwei Wang, Qiang Hu, Hongkuan Shi, Li He, Man He, Wenxuan Dai, Yinjiao Tian, Xin Yang, Mei Liu, Qiang Li

Box-supervised polyp segmentation attracts increasing attention for its cost-effective potential. Existing solutions often rely on learning-free methods or pretrained models to laboriously generate pseudo masks, triggering Dice constraint subsequently. In this paper, we found that a model guided by the simplest box-filled masks can accurately predict polyp locations/sizes, but suffers from shape collapsing. In response, we propose two innovative learning fashions, Improved Box-dice (IBox) and Contrastive Latent-Anchors (CLA), and combine them to train a robust box-supervised model IBoxCLA. The core idea behind IBoxCLA is to decouple the learning of location/size and shape, allowing for focused constraints on each of them. Specifically, IBox transforms the segmentation map into a proxy map using shape decoupling and confusion-region swapping sequentially. Within the proxy map, shapes are disentangled, while locations/sizes are encoded as box-like responses. By constraining the proxy map instead of the raw prediction, the box-filled mask can well supervise IBoxCLA without misleading its shape learning. Furthermore, CLA contributes to shape learning by generating two types of latent anchors, which are learned and updated using momentum and segmented polyps to steadily represent polyp and background features. The latent anchors facilitate IBoxCLA to capture discriminative features within and outside boxes in a contrastive manner, yielding clearer boundaries. We benchmark IBoxCLA on five public polyp datasets. The experimental results demonstrate the competitive performance of IBoxCLA compared to recent fully-supervised polyp segmentation methods, and its superiority over other box-supervised state-of-the-arts with a relative increase of overall mDice and mIoU by at least 6.5% and 7.5%, respectively.

Read more

9/16/2024

MonoBox: Tightness-free Box-supervised Polyp Segmentation using Monotonicity Constraint
Total Score

0

MonoBox: Tightness-free Box-supervised Polyp Segmentation using Monotonicity Constraint

Qiang Hu, Zhenyu Yi, Ying Zhou, Ting Li, Fan Huang, Mei Liu, Qiang Li, Zhiwei Wang

We propose MonoBox, an innovative box-supervised segmentation method constrained by monotonicity to liberate its training from the user-unfriendly box-tightness assumption. In contrast to conventional box-supervised segmentation, where the box edges must precisely touch the target boundaries, MonoBox leverages imprecisely-annotated boxes to achieve robust pixel-wise segmentation. The 'linchpin' is that, within the noisy zones around box edges, MonoBox discards the traditional misguiding multiple-instance learning loss, and instead optimizes a carefully-designed objective, termed monotonicity constraint. Along directions transitioning from the foreground to background, this new constraint steers responses to adhere to a trend of monotonically decreasing values. Consequently, the originally unreliable learning within the noisy zones is transformed into a correct and effective monotonicity optimization. Moreover, an adaptive label correction is introduced, enabling MonoBox to enhance the tightness of box annotations using predicted masks from the previous epoch and dynamically shrink the noisy zones as training progresses. We verify MonoBox in the box-supervised segmentation task of polyps, where satisfying box-tightness is challenging due to the vague boundaries between the polyp and normal tissues. Experiments on both public synthetic and in-house real noisy datasets demonstrate that MonoBox exceeds other anti-noise state-of-the-arts by improving Dice by at least 5.5% and 3.3%, respectively. Codes are at https://github.com/Huster-Hq/MonoBox.

Read more

6/26/2024

MixPolyp: Integrating Mask, Box and Scribble Supervision for Enhanced Polyp Segmentation
Total Score

0

MixPolyp: Integrating Mask, Box and Scribble Supervision for Enhanced Polyp Segmentation

Yiwen Hu, Jun Wei, Yuncheng Jiang, Haoyang Li, Shuguang Cui, Zhen Li, Song Wu

Limited by the expensive labeling, polyp segmentation models are plagued by data shortages. To tackle this, we propose the mixed supervised polyp segmentation paradigm (MixPolyp). Unlike traditional models relying on a single type of annotation, MixPolyp combines diverse annotation types (mask, box, and scribble) within a single model, thereby expanding the range of available data and reducing labeling costs. To achieve this, MixPolyp introduces three novel supervision losses to handle various annotations: Subspace Projection loss (L_SP), Binary Minimum Entropy loss (L_BME), and Linear Regularization loss (L_LR). For box annotations, L_SP eliminates shape inconsistencies between the prediction and the supervision. For scribble annotations, L_BME provides supervision for unlabeled pixels through minimum entropy constraint, thereby alleviating supervision sparsity. Furthermore, L_LR provides dense supervision by enforcing consistency among the predictions, thus reducing the non-uniqueness. These losses are independent of the model structure, making them generally applicable. They are used only during training, adding no computational cost during inference. Extensive experiments on five datasets demonstrate MixPolyp's effectiveness.

Read more

9/26/2024

Robust Box Prompt based SAM for Medical Image Segmentation
Total Score

0

Robust Box Prompt based SAM for Medical Image Segmentation

Yuhao Huang, Xin Yang, Han Zhou, Yan Cao, Haoran Dou, Fajin Dong, Dong Ni

The Segment Anything Model (SAM) can achieve satisfactory segmentation performance under high-quality box prompts. However, SAM's robustness is compromised by the decline in box quality, limiting its practicality in clinical reality. In this study, we propose a novel Robust Box prompt based SAM (textbf{RoBox-SAM}) to ensure SAM's segmentation performance under prompts with different qualities. Our contribution is three-fold. First, we propose a prompt refinement module to implicitly perceive the potential targets, and output the offsets to directly transform the low-quality box prompt into a high-quality one. We then provide an online iterative strategy for further prompt refinement. Second, we introduce a prompt enhancement module to automatically generate point prompts to assist the box-promptable segmentation effectively. Last, we build a self-information extractor to encode the prior information from the input image. These features can optimize the image embeddings and attention calculation, thus, the robustness of SAM can be further enhanced. Extensive experiments on the large medical segmentation dataset including 99,299 images, 5 modalities, and 25 organs/targets validated the efficacy of our proposed RoBox-SAM.

Read more

8/1/2024