Multiclass Arrhythmia Classification using Smartwatch Photoplethysmography Signals Collected in Real-life Settings

Read original: arXiv:2409.06147 - Published 9/11/2024 by Dong Han, Jihye Moon, Lu'is Roberto Mercado D'iaz, Darren Chen, Devan Williams, Eric Y. Ding, Khanh-Van Tran, David D. McManus, Ki H. Chon
Total Score

0

Multiclass Arrhythmia Classification using Smartwatch Photoplethysmography Signals Collected in Real-life Settings

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This research paper explores the use of smartwatch photoplethysmography (PPG) signals to classify different types of heart arrhythmias in real-life settings.
  • The study aims to develop a multiclass arrhythmia classification system that can accurately detect various heart rhythm abnormalities from PPG data collected by smartwatches.
  • The research has implications for improving remote heart health monitoring and early detection of cardiac issues.

Plain English Explanation

The paper investigates using data from smartwatch sensors to identify different types of heart arrhythmias, which are irregular heartbeats. Smartwatches can measure photoplethysmography (PPG) signals, which reflect changes in blood volume in the wrist. The researchers developed a machine learning system that can analyze these PPG signals to automatically detect and classify various heart rhythm problems, including atrial fibrillation, bradycardia, and tachycardia. This technology could enable more widespread, continuous monitoring of heart health using widely available smartwatch devices, potentially leading to earlier diagnosis and treatment of cardiac issues.

Technical Explanation

The researchers collected PPG data from participants' smartwatches while they went about their daily lives. This "real-life" data included signals corresponding to various heart arrhythmias, which the researchers manually labeled. They then developed a deep learning model that could automatically classify the PPG signals into one of five categories: normal sinus rhythm, atrial fibrillation, bradycardia, tachycardia, and other arrhythmias.

The model used a convolutional neural network (CNN) architecture to extract relevant features from the raw PPG waveforms. The CNN was followed by long short-term memory (LSTM) layers to capture the temporal dynamics of the PPG signals. The researchers evaluated the model's performance using various metrics, including accuracy, precision, recall, and F1-score, and found that it achieved high classification accuracy across the different arrhythmia types.

Critical Analysis

The study demonstrates the potential of using smartwatch PPG signals for continuous, real-world monitoring and classification of heart arrhythmias. However, the researchers acknowledge several limitations:

  • The dataset was relatively small, and future studies should validate the model on larger, more diverse populations.
  • The real-life data collection process may have introduced noise and artifacts that could impact the model's performance in a clinical setting.
  • The researchers did not compare the model's performance to that of medical professionals or other arrhythmia detection methods, such as electrocardiography (ECG).

Additionally, the paper does not fully address the potential challenges of deploying such a system in a real-world setting, such as ensuring data privacy, integrating with existing healthcare systems, and gaining regulatory approval. Further research is needed to address these practical concerns and demonstrate the clinical utility of the approach.

Conclusion

This research suggests that smartwatch PPG signals can be effectively used to develop a multiclass arrhythmia classification system that can detect various heart rhythm abnormalities in real-life settings. If validated and refined further, this technology could enable more widespread, continuous monitoring of heart health and lead to earlier identification and treatment of cardiac issues. However, the findings should be considered in light of the study's limitations, and additional research is needed to fully understand the practical implications and clinical applicability of this approach.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Multiclass Arrhythmia Classification using Smartwatch Photoplethysmography Signals Collected in Real-life Settings
Total Score

0

Multiclass Arrhythmia Classification using Smartwatch Photoplethysmography Signals Collected in Real-life Settings

Dong Han, Jihye Moon, Lu'is Roberto Mercado D'iaz, Darren Chen, Devan Williams, Eric Y. Ding, Khanh-Van Tran, David D. McManus, Ki H. Chon

Most deep learning models of multiclass arrhythmia classification are tested on fingertip photoplethysmographic (PPG) data, which has higher signal-to-noise ratios compared to smartwatch-derived PPG, and the best reported sensitivity value for premature atrial/ventricular contraction (PAC/PVC) detection is only 75%. To improve upon PAC/PVC detection sensitivity while maintaining high AF detection, we use multi-modal data which incorporates 1D PPG, accelerometers, and heart rate data as the inputs to a computationally efficient 1D bi-directional Gated Recurrent Unit (1D-Bi-GRU) model to detect three arrhythmia classes. We used motion-artifact prone smartwatch PPG data from the NIH-funded Pulsewatch clinical trial. Our multimodal model tested on 72 subjects achieved an unprecedented 83% sensitivity for PAC/PVC detection while maintaining a high accuracy of 97.31% for AF detection. These results outperformed the best state-of-the-art model by 20.81% for PAC/PVC and 2.55% for AF detection even while our model was computationally more efficient (14 times lighter and 2.7 faster).

Read more

9/11/2024

🏷️

Total Score

0

ECG Classification System for Arrhythmia Detection Using Convolutional Neural Networks

Aryan Odugoudar, Jaskaran Singh Walia

Arrhythmia is just one of the many cardiovascular illnesses that have been extensively studied throughout the years. Using multi-lead ECG data, this research describes a deep learning (DL) pipeline technique based on convolutional neural network (CNN) algorithms to detect cardiovascular lar arrhythmia in patients. The suggested model architecture has hidden layers with a residual block in addition to the input and output layers. In this study, the classification of the ECG signals into five main groups, namely: Left Bundle Branch Block (LBBB), Right Bundle Branch Block (RBBB), Atrial Premature Contraction (APC), Premature Ventricular Contraction (PVC), and Normal Beat (N), are performed. Using the MIT-BIH arrhythmia dataset, we assessed the suggested technique. The findings show that our suggested strategy classified 15,000 cases with a high accuracy of 98.2%

Read more

6/13/2024

🔎

Total Score

0

PPG-to-ECG Signal Translation for Continuous Atrial Fibrillation Detection via Attention-based Deep State-Space Modeling

Khuong Vo, Mostafa El-Khamy, Yoojin Choi

Photoplethysmography (PPG) is a cost-effective and non-invasive technique that utilizes optical methods to measure cardiac physiology. PPG has become increasingly popular in health monitoring and is used in various commercial and clinical wearable devices. Compared to electrocardiography (ECG), PPG does not provide substantial clinical diagnostic value, despite the strong correlation between the two. Here, we propose a subject-independent attention-based deep state-space model (ADSSM) to translate PPG signals to corresponding ECG waveforms. The model is not only robust to noise but also data-efficient by incorporating probabilistic prior knowledge. To evaluate our approach, 55 subjects' data from the MIMIC-III database were used in their original form, and then modified with noise, mimicking real-world scenarios. Our approach was proven effective as evidenced by the PR-AUC of 0.986 achieved when inputting the translated ECG signals into an existing atrial fibrillation (AFib) detector. ADSSM enables the integration of ECG's extensive knowledge base and PPG's continuous measurement for early diagnosis of cardiovascular disease.

Read more

6/13/2024

KID-PPG: Knowledge Informed Deep Learning for Extracting Heart Rate from a Smartwatch
Total Score

0

KID-PPG: Knowledge Informed Deep Learning for Extracting Heart Rate from a Smartwatch

Christodoulos Kechris, Jonathan Dan, Jose Miranda, David Atienza

Accurate extraction of heart rate from photoplethysmography (PPG) signals remains challenging due to motion artifacts and signal degradation. Although deep learning methods trained as a data-driven inference problem offer promising solutions, they often underutilize existing knowledge from the medical and signal processing community. In this paper, we address three shortcomings of deep learning models: motion artifact removal, degradation assessment, and physiologically plausible analysis of the PPG signal. We propose KID-PPG, a knowledge-informed deep learning model that integrates expert knowledge through adaptive linear filtering, deep probabilistic inference, and data augmentation. We evaluate KID-PPG on the PPGDalia dataset, achieving an average mean absolute error of 2.85 beats per minute, surpassing existing reproducible methods. Our results demonstrate a significant performance improvement in heart rate tracking through the incorporation of prior knowledge into deep learning models. This approach shows promise in enhancing various biomedical applications by incorporating existing expert knowledge in deep learning models.

Read more

5/17/2024