PPG-to-ECG Signal Translation for Continuous Atrial Fibrillation Detection via Attention-based Deep State-Space Modeling

Read original: arXiv:2309.15375 - Published 6/13/2024 by Khuong Vo, Mostafa El-Khamy, Yoojin Choi
Total Score

0

🔎

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Photoplethysmography (PPG) is a non-invasive technique that uses optical methods to measure cardiac physiology.
  • PPG is commonly used in wearable health monitoring devices, but it has limited clinical diagnostic value compared to electrocardiography (ECG).
  • The paper proposes an attention-based deep state-space model (ADSSM) to translate PPG signals into corresponding ECG waveforms, enabling the integration of ECG's extensive knowledge base and PPG's continuous measurement.

Plain English Explanation

Photoplethysmography (PPG) is a technique that uses light to measure changes in blood volume and track the heart's activity. It's a low-cost and non-invasive way to monitor your heart health, and it's commonly used in wearable devices like fitness trackers and smartwatches. However, while PPG can give you a good sense of your heart's activity, it doesn't provide the same level of detailed clinical information as electrocardiography (ECG), which directly measures the electrical signals from your heart.

This paper proposes a new approach to bridge the gap between PPG and ECG. The researchers developed a deep learning model called ADSSM that can take PPG signals and translate them into corresponding ECG waveforms. This allows you to get the benefits of continuous PPG monitoring while also tapping into the wealth of medical knowledge that's been built up around ECG.

The key advantage of this approach is that it's robust to noise and efficient in its use of data, thanks to the way the model incorporates prior knowledge about the relationship between PPG and ECG. This means it can work well even in real-world scenarios where the PPG signal might be noisy or incomplete.

Technical Explanation

The paper presents an attention-based deep state-space model (ADSSM) that can translate PPG signals into corresponding ECG waveforms. The model is designed to be robust to noise and data-efficient by incorporating probabilistic prior knowledge about the relationship between PPG and ECG.

The researchers evaluated their approach using data from 55 subjects in the MIMIC-III database. They took the original PPG and ECG data, and then added noise to mimic real-world conditions. When they fed the translated ECG signals from their ADSSM model into an existing atrial fibrillation (AFib) detector, the system achieved a PR-AUC (precision-recall area under the curve) of 0.986, demonstrating the effectiveness of the approach.

Key aspects of the ADSSM model include:

  • An attention mechanism that allows the model to focus on the most relevant parts of the PPG signal when generating the ECG waveform
  • A state-space formulation that captures the dynamic, time-series nature of the signals
  • The incorporation of probabilistic prior knowledge to improve data efficiency and robustness

By bridging the gap between PPG and ECG, this approach enables the integration of ECG's extensive medical knowledge base with the continuous, non-invasive monitoring capabilities of PPG. This could lead to earlier detection and diagnosis of cardiovascular diseases.

Critical Analysis

The paper presents a promising approach to translating PPG signals into ECG waveforms, but there are a few potential limitations and areas for further research:

  • The evaluation was limited to a single dataset (MIMIC-III) and a specific task (AFib detection). More extensive testing across a broader range of clinical scenarios would be needed to fully assess the model's capabilities.

  • While the model is designed to be robust to noise, the paper doesn't provide a comprehensive analysis of its performance under different types and levels of noise. Further research could explore the model's limits and how it compares to other noise-resilient approaches.

  • The paper doesn't address the potential for drift or misalignment between the PPG and ECG signals, which could impact the model's performance in real-world settings. Strategies to detect and correct for such issues may be needed.

  • The generalization of the model to sleep staging or other healthcare applications beyond AFib detection could be an interesting area for further exploration.

Overall, the ADSSM approach shows promise, but additional research and validation would be needed to fully understand its capabilities and limitations in clinical settings. A vision transformer-based approach could also be an interesting alternative to explore.

Conclusion

This paper presents an attention-based deep state-space model (ADSSM) that can effectively translate PPG signals into corresponding ECG waveforms. By bridging the gap between these two modalities, the approach enables the integration of ECG's extensive medical knowledge base with the continuous, non-invasive monitoring capabilities of PPG.

The model's robustness to noise and data-efficiency make it a promising tool for early diagnosis and monitoring of cardiovascular diseases in real-world settings. While further research is needed to fully assess its capabilities, this work represents an important step towards leveraging the complementary strengths of PPG and ECG for improved healthcare outcomes.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🔎

Total Score

0

PPG-to-ECG Signal Translation for Continuous Atrial Fibrillation Detection via Attention-based Deep State-Space Modeling

Khuong Vo, Mostafa El-Khamy, Yoojin Choi

Photoplethysmography (PPG) is a cost-effective and non-invasive technique that utilizes optical methods to measure cardiac physiology. PPG has become increasingly popular in health monitoring and is used in various commercial and clinical wearable devices. Compared to electrocardiography (ECG), PPG does not provide substantial clinical diagnostic value, despite the strong correlation between the two. Here, we propose a subject-independent attention-based deep state-space model (ADSSM) to translate PPG signals to corresponding ECG waveforms. The model is not only robust to noise but also data-efficient by incorporating probabilistic prior knowledge. To evaluate our approach, 55 subjects' data from the MIMIC-III database were used in their original form, and then modified with noise, mimicking real-world scenarios. Our approach was proven effective as evidenced by the PR-AUC of 0.986 achieved when inputting the translated ECG signals into an existing atrial fibrillation (AFib) detector. ADSSM enables the integration of ECG's extensive knowledge base and PPG's continuous measurement for early diagnosis of cardiovascular disease.

Read more

6/13/2024

Uncertainty-Aware PPG-2-ECG for Enhanced Cardiovascular Diagnosis using Diffusion Models
Total Score

0

Uncertainty-Aware PPG-2-ECG for Enhanced Cardiovascular Diagnosis using Diffusion Models

Omer Belhasin, Idan Kligvasser, George Leifman, Regev Cohen, Erin Rainaldi, Li-Fang Cheng, Nishant Verma, Paul Varghese, Ehud Rivlin, Michael Elad

Analyzing the cardiovascular system condition via Electrocardiography (ECG) is a common and highly effective approach, and it has been practiced and perfected over many decades. ECG sensing is non-invasive and relatively easy to acquire, and yet it is still cumbersome for holter monitoring tests that may span over hours and even days. A possible alternative in this context is Photoplethysmography (PPG): An optically-based signal that measures blood volume fluctuations, as typically sensed by conventional ``wearable devices''. While PPG presents clear advantages in acquisition, convenience, and cost-effectiveness, ECG provides more comprehensive information, allowing for a more precise detection of heart conditions. This implies that a conversion from PPG to ECG, as recently discussed in the literature, inherently involves an unavoidable level of uncertainty. In this paper we introduce a novel methodology for addressing the PPG-2-ECG conversion, and offer an enhanced classification of cardiovascular conditions using the given PPG, all while taking into account the uncertainties arising from the conversion process. We provide a mathematical justification for our proposed computational approach, and present empirical studies demonstrating its superior performance compared to state-of-the-art baseline methods.

Read more

5/21/2024

Multiclass Arrhythmia Classification using Smartwatch Photoplethysmography Signals Collected in Real-life Settings
Total Score

0

Multiclass Arrhythmia Classification using Smartwatch Photoplethysmography Signals Collected in Real-life Settings

Dong Han, Jihye Moon, Lu'is Roberto Mercado D'iaz, Darren Chen, Devan Williams, Eric Y. Ding, Khanh-Van Tran, David D. McManus, Ki H. Chon

Most deep learning models of multiclass arrhythmia classification are tested on fingertip photoplethysmographic (PPG) data, which has higher signal-to-noise ratios compared to smartwatch-derived PPG, and the best reported sensitivity value for premature atrial/ventricular contraction (PAC/PVC) detection is only 75%. To improve upon PAC/PVC detection sensitivity while maintaining high AF detection, we use multi-modal data which incorporates 1D PPG, accelerometers, and heart rate data as the inputs to a computationally efficient 1D bi-directional Gated Recurrent Unit (1D-Bi-GRU) model to detect three arrhythmia classes. We used motion-artifact prone smartwatch PPG data from the NIH-funded Pulsewatch clinical trial. Our multimodal model tested on 72 subjects achieved an unprecedented 83% sensitivity for PAC/PVC detection while maintaining a high accuracy of 97.31% for AF detection. These results outperformed the best state-of-the-art model by 20.81% for PAC/PVC and 2.55% for AF detection even while our model was computationally more efficient (14 times lighter and 2.7 faster).

Read more

9/11/2024

f-GAN: A frequency-domain-constrained generative adversarial network for PPG to ECG synthesis
Total Score

0

f-GAN: A frequency-domain-constrained generative adversarial network for PPG to ECG synthesis

Nathan C. L. Kong, Dae Lee, Huyen Do, Dae Hoon Park, Cong Xu, Hongda Mao, Jonathan Chung

Electrocardiograms (ECGs) and photoplethysmograms (PPGs) are generally used to monitor an individual's cardiovascular health. In clinical settings, ECGs and fingertip PPGs are the main signals used for assessing cardiovascular health, but the equipment necessary for their collection precludes their use in daily monitoring. Although PPGs obtained from wrist-worn devices are susceptible to noise due to motion, they have been widely used to continuously monitor cardiovascular health because of their convenience. Therefore, we would like to combine the ease with which PPGs can be collected with the information that ECGs provide about cardiovascular health by developing models to synthesize ECG signals from paired PPG signals. We tackled this problem using generative adversarial networks (GANs) and found that models trained using the original GAN formulations can be successfully used to synthesize ECG signals from which heart rate can be extracted using standard signal processing pipelines. Incorporating a frequency-domain constraint to model training improved the stability of model performance and also the performance on heart rate estimation.

Read more

6/26/2024