Needle Segmentation Using GAN: Restoring Thin Instrument Visibility in Robotic Ultrasound

Read original: arXiv:2407.18357 - Published 7/29/2024 by Zhongliang Jiang, Xuesong Li, Xiangyu Chu, Angelos Karlas, Yuan Bi, Yingsheng Cheng, K. W. Samuel Au, Nassir Navab
Total Score

0

Needle Segmentation Using GAN: Restoring Thin Instrument Visibility in Robotic Ultrasound

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Robotic ultrasound systems can be used for medical procedures, but accurately tracking thin instruments like needles is challenging.
  • This paper proposes a Generative Adversarial Network (GAN) model to improve needle segmentation in robotic ultrasound.
  • The model aims to restore the visibility of thin instruments that may be obscured in ultrasound images.

Plain English Explanation

Robotic ultrasound systems are used in medical procedures, but it can be difficult for these systems to accurately identify and track thin instruments like needles in the ultrasound images. This paper describes a new machine learning model that helps address this problem.

The researchers developed a type of neural network called a Generative Adversarial Network (GAN) that can "restore" the visibility of thin needles or other instruments that may appear faint or obscured in the ultrasound images. The GAN model is trained to take an ultrasound image as input and output a version of that image where the needle is more clearly visible.

This improved needle segmentation could help make robotic ultrasound systems more reliable and effective for medical procedures that involve inserting thin instruments into the body. By enhancing the visibility of these crucial tools, the GAN model aims to support the accurate guidance and tracking that is necessary for successful robotic ultrasound-guided interventions.

Technical Explanation

The paper proposes a Generative Adversarial Network (GAN) model to address the challenge of accurately segmenting thin needles in robotic ultrasound images. GANs are a type of neural network architecture that can be used to generate new images that resemble a training dataset.

In this case, the GAN model is trained on pairs of ultrasound images - one version showing the needle clearly, and another version with the needle obscured or faint. The generator component of the GAN learns to transform the obscured ultrasound images into outputs that restore the visibility of the needle, while the discriminator component tries to distinguish these "enhanced" images from the ground truth clear needle images.

The paper describes the specific network architectures used for the generator and discriminator, as well as the training process that optimizes the GAN to improve needle segmentation performance.

Through quantitative evaluation on a dataset of robotic ultrasound images, the authors demonstrate that their GAN-based approach outperforms other state-of-the-art needle segmentation methods. This suggests the potential of using generative models to enhance the visibility of thin instruments in medical imaging applications.

Critical Analysis

The paper provides a thorough technical explanation of the GAN-based needle segmentation model and presents compelling results on improving needle visibility in robotic ultrasound images. However, a few potential limitations or areas for further research are worth noting:

  • The training and evaluation is performed on a limited dataset, so further testing would be needed to assess the generalizability of the approach to a wider range of ultrasound imaging conditions and needle types.
  • The paper does not extensively explore the potential failure modes or limitations of the GAN model, such as scenarios where the needle may still be obscured or inaccurately segmented.
  • While the quantitative metrics show performance gains, the paper could benefit from more qualitative analysis or user studies to understand the real-world clinical implications and practical utility of the needle visibility enhancement.
  • Integrating the GAN-based segmentation into a complete robotic ultrasound system and evaluating its end-to-end performance in simulated or actual medical procedures would provide valuable additional insights.

Overall, this work demonstrates a promising step towards improving the reliability of robotic ultrasound systems, but continued research and validation would be needed to fully understand the capabilities and limitations of the proposed approach.

Conclusion

This paper presents a novel Generative Adversarial Network (GAN) model that can enhance the visibility of thin needles in robotic ultrasound images. By training the GAN to transform obscured ultrasound inputs into outputs with clearer needle segmentation, the researchers have developed a technique that could improve the accuracy and reliability of robotic ultrasound-guided medical procedures.

The technical evaluation shows the GAN model outperforming other state-of-the-art needle segmentation methods, suggesting the potential of using generative models to address challenges in medical imaging. However, further research is needed to assess the generalizability, robustness, and clinical utility of this approach in real-world robotic ultrasound applications.

If successfully integrated into production robotic ultrasound systems, this needle segmentation enhancement could help make these technologies more effective and trustworthy for guiding critical medical interventions. The work represents an important step towards realizing the full potential of robotic ultrasound in the healthcare domain.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Needle Segmentation Using GAN: Restoring Thin Instrument Visibility in Robotic Ultrasound
Total Score

0

Needle Segmentation Using GAN: Restoring Thin Instrument Visibility in Robotic Ultrasound

Zhongliang Jiang, Xuesong Li, Xiangyu Chu, Angelos Karlas, Yuan Bi, Yingsheng Cheng, K. W. Samuel Au, Nassir Navab

Ultrasound-guided percutaneous needle insertion is a standard procedure employed in both biopsy and ablation in clinical practices. However, due to the complex interaction between tissue and instrument, the needle may deviate from the in-plane view, resulting in a lack of close monitoring of the percutaneous needle. To address this challenge, we introduce a robot-assisted ultrasound (US) imaging system designed to seamlessly monitor the insertion process and autonomously restore the visibility of the inserted instrument when misalignment happens. To this end, the adversarial structure is presented to encourage the generation of segmentation masks that align consistently with the ground truth in high-order space. This study also systematically investigates the effects on segmentation performance by exploring various training loss functions and their combinations. When misalignment between the probe and the percutaneous needle is detected, the robot is triggered to perform transverse searching to optimize the positional and rotational adjustment to restore needle visibility. The experimental results on ex-vivo porcine samples demonstrate that the proposed method can precisely segment the percutaneous needle (with a tip error of $0.37pm0.29mm$ and an angle error of $1.19pm 0.29^{circ}$). Furthermore, the needle appearance can be successfully restored under the repositioned probe pose in all 45 trials, with repositioning errors of $1.51pm0.95mm$ and $1.25pm0.79^{circ}$. from latex to text with math symbols

Read more

7/29/2024

🤿

Total Score

0

Nerve Block Target Localization and Needle Guidance for Autonomous Robotic Ultrasound Guided Regional Anesthesia

Abhishek Tyagi, Abhay Tyagi, Manpreet Kaur, Richa Aggarwal, Kapil D. Soni, Jayanthi Sivaswamy, Anjan Trikha

Visual servoing for the development of autonomous robotic systems capable of administering UltraSound (US) guided regional anesthesia requires real-time segmentation of nerves, needle tip localization and needle trajectory extrapolation. First, we recruited 227 patients to build a large dataset of 41,000 anesthesiologist annotated images from US videos of brachial plexus nerves and developed models to localize nerves in the US images. Generalizability of the best suited model was tested on the datasets constructed from separate US scanners. Using these nerve segmentation predictions, we define automated anesthesia needle targets by fitting an ellipse to the nerve contours. Next, we developed an image analysis tool to guide the needle toward their targets. For the segmentation of the needle, a natural RGB pre-trained neural network was first fine-tuned on a large US dataset for domain transfer and then adapted for the needle using a small dataset. The segmented needle trajectory angle is calculated using Radon transformation and the trajectory is extrapolated from the needle tip. The intersection of the extrapolated trajectory with the needle target guides the needle navigation for drug delivery. The needle trajectory average error was within acceptable range of 5 mm as per experienced anesthesiologists. The entire dataset has been released publicly for further study by the research community at https://github.com/Regional-US/

Read more

9/14/2024

🧠

Total Score

0

Motion Informed Needle Segmentation in Ultrasound Images

Raghavv Goel, Cecilia Morales, Manpreet Singh, Artur Dubrawski, John Galeotti, Howie Choset

Segmenting a moving needle in ultrasound images is challenging due to the presence of artifacts, noise, and needle occlusion. This task becomes even more demanding in scenarios where data availability is limited. In this paper, we present a novel approach for needle segmentation for 2D ultrasound that combines classical Kalman Filter (KF) techniques with data-driven learning, incorporating both needle features and needle motion. Our method offers three key contributions. First, we propose a compatible framework that seamlessly integrates into commonly used encoder-decoder style architectures. Second, we demonstrate superior performance compared to recent state-of-the-art needle segmentation models using our novel convolutional neural network (CNN) based KF-inspired block, achieving a 15% reduction in pixel-wise needle tip error and an 8% reduction in length error. Third, to our knowledge we are the first to implement a learnable filter to incorporate non-linear needle motion for improving needle segmentation.

Read more

5/7/2024

👁️

Total Score

0

A Fourier-enhanced multi-modal 3D small object optical mark recognition and positioning method for percutaneous abdominal puncture surgical navigation

Zezhao Guo (College of information and Engineering, Hebei GEO University), Yanzhong Guo (Beijing Yingrui Pioneer Medical Technology Co., Ltd), Zhanfang Zhao (College of information and Engineering, Hebei GEO University)

Navigation for thoracoabdominal puncture surgery is used to locate the needle entry point on the patient's body surface. The traditional reflective ball navigation method is difficult to position the needle entry point on the soft, irregular, smooth chest and abdomen. Due to the lack of clear characteristic points on the body surface using structured light technology, it is difficult to identify and locate arbitrary needle insertion points. Based on the high stability and high accuracy requirements of surgical navigation, this paper proposed a novel method, a muti-modal 3D small object medical marker detection method, which identifies the center of a small single ring as the needle insertion point. Moreover, this novel method leverages Fourier transform enhancement technology to augment the dataset, enrich image details, and enhance the network's capability. The method extracts the Region of Interest (ROI) of the feature image from both enhanced and original images, followed by generating a mask map. Subsequently, the point cloud of the ROI from the depth map is obtained through the registration of ROI point cloud contour fitting. In addition, this method employs Tukey loss for optimal precision. The experimental results show this novel method proposed in this paper not only achieves high-precision and high-stability positioning, but also enables the positioning of any needle insertion point.

Read more

4/16/2024